Technical Aspects of Implantation of LV Lead for Cardiac Resynchronization Therapy in Chronic Heart Failure

The goal of this study was to analyze total procedural and fluoroscopic time during initial experience with implantation of LV lead in a single center, and to assess the performance of electrophysiologically‐guided approach for cannulation of the coronary sinus (CS) in a subsequent period. Over an initial period of 29 months, a total of 46 attempts to implant biventricular pacing system were revised. During the first phase, only one type of LV electrode was available for three implanters (11 attempts). The second phase covered their early experience with other stylet‐controlled LV leads (10 attempts). Additional LV leads including the over‐the‐wire design were available in the third phase and 25 attempts were done by he most experienced implanter. In a period of advanced experience, 92 implant procedures performed by four implanters using an electrophysiologically‐guided approach to CS cannulation were revised. In the first period, success rates for different phases reached 70%, 90%, and 96%, respectively. Significant decrease in both procedural and fluoroscopic times was achieved with increased experience (Phase I: 247.1 ± 104.5 minutes and 31.2 ± 34.3 minutes, Phase II: 219.4 ± 85.6 minutes, and 22.9 ± 19.1 minutes, Phase III: 116.4 ± 89.9 minutes and 6.6 ± 4.4 minutes, respectively, P < 0.05). Advanced experience with electrophysiologically‐guided approach to CS cannulation allowed achievement of this target within a reasonable amount of time (15.4 ± 16.3 minutes) and with minimum fluoroscopic time (2.1 ± 2.9 minutes). In conclusion, both individual learning curve and technical advances significantly influence success rate, procedural, and fluoroscopic times for biventricular system implantation. Electrophysiologically‐guided approach makes cannulation of the CS a highly reproducible procedure that requires minimum fluoroscopic time. (PACE 2004; 27[Pt. I]:783–790)

[1]  C. Leclercq,et al.  Cardiac resynchronization therapy in advanced heart failure the multicenter InSync clinical study ☆ , 2002, European journal of heart failure.

[2]  D. Delurgio,et al.  Cardiac resynchronization in chronic heart failure. , 2002, The New England journal of medicine.

[3]  A. Lazarus,et al.  Multisite Pacing for End‐Stage Heart Failure: Early Experience , 1996, Pacing and clinical electrophysiology : PACE.

[4]  H. Pürerfellner,et al.  Transvenous left ventricular lead implantation with the EASYTRAK lead system: the European experience. , 2000, The American journal of cardiology.

[5]  J. Daubert,et al.  Six year experience of transvenous left ventricular lead implantation for permanent biventricular pacing in patients with advanced heart failure: technical aspects , 2001, Heart.

[6]  Andrew P. Kramer,et al.  Transvenous biventricular pacing for heart failure: can the obstacles be overcome? , 1999, The American journal of cardiology.

[7]  J. Daubert,et al.  Permanent Left Ventricular Pacing With Transvenous Leads Inserted Into The Coronary Veins , 1998, Pacing and clinical electrophysiology : PACE.

[8]  J. Daubert,et al.  Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. , 2001, The New England journal of medicine.

[9]  J. Hartikainen,et al.  Complications Related to Permanent Pacemaker Therapy , 1999, Pacing and clinical electrophysiology : PACE.

[10]  G. Mascioli,et al.  Left ventricular pacing lead choice based on coronary sinus venous anatomy , 2000 .

[11]  P. Brunel,et al.  Optimal Stimulation of the Left Ventricle , 2002, Journal of cardiovascular electrophysiology.

[12]  Milton Packer,et al.  Cardiac resynchronization in chronic heart failure. , 2002, The New England journal of medicine.

[13]  M. Santini,et al.  Cardiac resynchronization: Materials, technique and results. The InSync Italian Registry , 2000 .