An iterative reconstruction algorithm for single photon emission computed tomography with cone beam geometry

An iterative EM reconstruction algorithm for single photon emission computed tomography is implemented for cone beam geometry that uses a ray‐driven projector‐backprojector. The cone beam projector‐backprojector models the attenuated Radon transform of a source distributed within an attenuator as line integrals of discrete voxels representing the source and attenuation distributions. The attenuation coefficient distribution for each voxel is assumed to be equal to the average value over a cubical region, and the integral of the source concentration through each voxel is obtained by interpolating between the source values at eight neighboring voxels. The calculation of the attenuation factors requires a specification of the attenuation distribution, estimated either from an assumed constant distribution with an estimated body outline or from transmission measurements. The distribution of attenuation coefficients is stored in memory, and the attenuation factors are calculated for each voxel during the projection and backprojection operations instead of using precalculated values. Computer simulations of half‐scan and full‐scan reconstructions show that the algorithm is able to compensate for attentuation and to suppress the propagation of artifacts that can result with limited angular sampling. The simulations verify that the algorithm has important application to cardiac SPECT imaging; because of variable attentuation through the thorax, it is necessary to use an iterative algorithm with an attenuation map in order to quantify radiopharmaceutical distributions in the heart.

[1]  M. E. Davison,et al.  The Ill-Conditioned Nature of the Limited Angle Tomography Problem , 1983 .

[2]  E. Tanaka,et al.  Recent Progress on Single Photon and Positron Emission Tomography - From Detectors to Algorithms - , 1987, IEEE Transactions on Nuclear Science.

[3]  C E Floyd,et al.  Noise characteristics for cone beam collimators: a comparison with parallel hole collimator. , 1988, Physics in medicine and biology.

[4]  G Minerbo Maximum entropy reconstruction from cone-beam projection data. , 1979, Computers in biology and medicine.

[5]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[6]  Gengsheng L. Zeng,et al.  A study of reconstruction artifacts in cone beam tomography using filtered backprojection and iterative EM algorithms , 1990 .

[7]  S. Bellini,et al.  Compensation of tissue absorption in emission tomography , 1979 .

[8]  R J Jaszczak,et al.  SPECT using a specially designed cone beam collimator. , 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  Ronald J. Jaszczak,et al.  Maximum likelihood reconstruction for cone beam SPECT with camera tilt , 1989 .

[10]  Francoise C. Peyrin,et al.  The Generalized Back Projection Theorem for Cone Beam Reconstruction , 1985, IEEE Transactions on Nuclear Science.

[11]  H. Tuy AN INVERSION FORMULA FOR CONE-BEAM RECONSTRUCTION* , 1983 .

[12]  D. Gilland,et al.  Implementation of simultaneous attenuation and detector response correction in SPECT , 1988 .

[13]  Lee-Tzuu Chang,et al.  A Method for Attenuation Correction in Radionuclide Computed Tomography , 1978, IEEE Transactions on Nuclear Science.

[14]  J R Perry,et al.  Correction of nonuniform attenuation in cardiac SPECT imaging. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  L. Burkinshaw,et al.  Tomographic Reconstruction from Experimentally Obtained Cone-Beam Projections , 1987, IEEE Transactions on Medical Imaging.

[16]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[17]  V. Perez-Mendez,et al.  Limits to Image Reconstruction from Restricted Angular Input , 1980, IEEE Transactions on Nuclear Science.

[18]  K Torizuka,et al.  Determination of the pleural edge by gamma-ray transmission computed tomography. , 1981, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  B. Friedlander,et al.  Direct Three-Dimensional Image Reconstruction from Divergent Rays , 1979, IEEE Transactions on Nuclear Science.

[20]  David V. Finch CONE BEAM RECONSTRUCTION WITH SOURCES ON A CURVE , 1985 .

[21]  K. Tam,et al.  Tomographical imaging with limited-angle input , 1981 .

[22]  R. Huesman,et al.  Emission computed tomography , 1979 .

[23]  William G. Wee,et al.  On Methods of Three-Dimensional Reconstruction from a Set of Radioisotope Scintigrams , 1976, IEEE Transactions on Systems, Man, and Cybernetics.

[24]  G T Gullberg,et al.  The geometric transfer function for cone and fan beam collimators. , 1990, Physics in medicine and biology.

[25]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[26]  F. Natterer The Mathematics of Computerized Tomography , 1986 .

[27]  G. Minerbo Convolutional Reconstruction from Cone-Beam Projection Data , 1979, IEEE Transactions on Nuclear Science.

[28]  Victor Perez-Mendez,et al.  3-D Object Reconstruction in Emission and Transmission Tomography with Limited Angular Input , 1979, IEEE Transactions on Nuclear Science.

[29]  R. Jaszczak,et al.  Single Photon Emission Computed Tomography Using Multi-Slice Fan Beam Collimators , 1979 .

[30]  B. D. Smith Cone beam convolution formula. , 1983, Computers in biology and medicine.

[31]  T. Budinger,et al.  Three-dimensional reconstruction in nuclear medicine emission imaging , 1974 .

[32]  Thomas F. Budinger,et al.  The Use of Filtering Methods to Compensate for Constant Attenuation in Single-Photon Emission Computed Tomography , 1981 .

[33]  P. Grant,et al.  Considerations of carrier (continued) , 1982, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[34]  G T Gullberg,et al.  SPECT liver imaging using an iterative attenuation correction algorithm and an external flood source. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[35]  C. Metz,et al.  The exponential Radon transform , 1980 .

[36]  V. Perez-Mendez,et al.  Limited Angle 3-D Reconstructions from Continuous and Pinhole Projections , 1980, IEEE Transactions on Nuclear Science.

[37]  Bruce D. Smith Image Reconstruction from Cone-Beam Projections: Necessary and Sufficient Conditions and Reconstruction Methods , 1985, IEEE Transactions on Medical Imaging.

[38]  R A Robb,et al.  Three‐Dimensional Spatial, Density, and Temporal Resolution of the Dynamic Spatial Reconstructor , 1982, Journal of computer assisted tomography.

[39]  Ronald J. Jaszczak,et al.  A Practical Attenuation Compensation Method for Cone Beam SPECT , 1987, IEEE Transactions on Nuclear Science.

[40]  R J Jaszczak,et al.  Whole-body single-photon emission computed tomography using dual, large-field-of-view scintillation cameras , 1979, Physics in medicine and biology.

[41]  Quantitative multi-detector emission computerized tomography using iterative attenuation compensation. , 1982, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[42]  R. Jaszczak,et al.  Cone beam collimation for single photon emission computed tomography: analysis, simulation, and image reconstruction using filtered backprojection. , 1986, Medical physics.

[43]  H. Tuy Reconstruction of a three-dimensional object from a limited range of views , 1981 .

[44]  O. Nalcioglu,et al.  Reconstruction of 3-D objects from cone beam projections , 1978, Proceedings of the IEEE.

[45]  N. Pelc,et al.  An attenuated projector-backprojector for iterative SPECT reconstruction. , 1985, Physics in medicine and biology.

[46]  D R Gilland,et al.  Design and clinical utility of a fan beam collimator for SPECT imaging of the head. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[47]  Influence of the Depth Effect on Quantitative Results in Single Photon Emission Tomography with Attenuation Correction , 1984, IEEE Transactions on Nuclear Science.

[48]  R W Parkey,et al.  Attenuation compensation in single-photon emission tomography: a comparative evaluation. , 1982, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[49]  C. E. Floyd,et al.  Cone Beam Collimation for SPECT: Simulation and Reconstruction , 1986, IEEE Transactions on Nuclear Science.

[50]  R. Jaszczak,et al.  Imaging characteristics of a high resolution cone beam collimator , 1988 .

[51]  S Webb,et al.  A comparison of attenuation correction methods for quantitative single photon emission computed tomography. , 1983, Physics in medicine and biology.

[52]  E Tanaka,et al.  Quantitative image reconstruction with weighted backprojection for single photon emission computed tomography. , 1983, Journal of computer assisted tomography.

[53]  Hui Hu,et al.  Quantitative Cone-Beam Reconstruction , 1989, Medical Imaging.

[54]  D E Kuhl,et al.  Quantitative section scanning using orthogonal tangent correction. , 1973, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[55]  W Simon,et al.  Attenuation Correction in Gamma Emission Computed Tomography , 1981, Journal of computer assisted tomography.

[56]  G. Kowalski Multislice Reconstruction from Twin-Cone Beam Scanning , 1979, IEEE Transactions on Nuclear Science.

[57]  G T Gullberg,et al.  Estimation of geometrical parameters and collimator evaluation for cone beam tomography. , 1990, Medical physics.