Preliminary performance of a surgically implanted neuroprosthesis for standing and transfers--where do we stand?
暂无分享,去创建一个
[1] R Kobetic,et al. Effects of stimulated hip extension moment and position on upper-limb support forces during FNS-induced standing--a technical note. , 2001, Journal of rehabilitation research and development.
[2] N Bhadra,et al. Surgical technique for installing an eight-channel neuroprosthesis for standing. , 2001, Clinical orthopaedics and related research.
[3] R Kobetic,et al. The use of selective electrical stimulation of the quadriceps to improve standing function in paraplegia. , 2000, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.
[4] E. Marsolais,et al. Implantation of a 16‐Channel Functional Electrical Stimulation Walking System , 1998, Clinical orthopaedics and related research.
[5] Z Jin,et al. Rail supporting transducer posts for three-dimensional force measurement. , 1997, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.
[6] P H Peckham,et al. Tissue response to chronically stimulated implanted epimysial and intramuscular electrodes. , 1997, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.
[7] R J Triolo,et al. Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia. , 1997, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.
[8] 朱图陵译 赵辉三校,et al. Journal of Rehabilitation Research and Development《康复研究与开发杂志》目录 , 1996 .
[9] G. Obinata,et al. Restoration and analysis of standing-up in complete paraplegia utilizing functional electrical stimulation. , 1995, Archives of physical medicine and rehabilitation.
[10] T. Kotake,et al. An analysis of sit-to-stand movements. , 1993, Archives of physical medicine and rehabilitation.
[11] U P Arborelius,et al. The effects of armrests and high seat heights on lower-limb joint load and muscular activity during sitting and rising. , 1992, Ergonomics.
[12] B. Smith,et al. In-line lead connector for use with implanted neuroprosthesis , 1991, IEEE Transactions on Biomedical Engineering.
[13] P. H. Peckham,et al. A surgically-implanted intramuscular electrode for an implantable neuromuscular stimulation system , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.
[14] T. Andriacchi,et al. The influence of chair height on lower limb mechanics during rising , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[15] Dennis D. Roscoe,et al. An Externally Powered, Multichannel, Implantable Stimulator for Versatile Control of Paralyzed Muscle , 1987, IEEE Transactions on Biomedical Engineering.
[16] Z Jin,et al. Instrumented parallel bars for three-dimensional force measurement. , 1992, Journal of rehabilitation research and development.
[17] R. Stein,et al. Neural prostheses : replacing motor function after disease or disability , 1992 .
[18] T Bajd,et al. Standing-up of a healthy subject and a paraplegic patient. , 1982, Journal of biomechanics.