Statistical interpretation of "femtomolar" detection.

We calculate the statistics of diffusion-limited arrival-time distribution by a Monte Carlo method to suggest a simple statistical resolution of the enduring puzzle of nanobiosensors: a persistent gap between reports of analyte detection at approximately femtomolar concentration and theory suggesting the impossibility of approximately subpicomolar detection at the corresponding incubation time. The incubation time used in the theory is actually the mean incubation time, while experimental conditions suggest that device stability limited the minimum incubation time. The difference in incubation times-both described by characteristic power laws-provides an intuitive explanation of different detection limits anticipated by theory and experiments.

[1]  N. Butt,et al.  Soft Error Trends and New Physical Model for Ionizing Dose Effects in Double Gate Z-RAM Cell , 2007, IEEE Transactions on Nuclear Science.

[2]  J. Bishop,et al.  Convective flow effects on DNA biosensors. , 2007, Biosensors & bioelectronics.

[3]  Gengfeng Zheng,et al.  Multiplexed electrical detection of cancer markers with nanowire sensor arrays , 2005, Nature Biotechnology.

[4]  Muhammad A. Alam,et al.  Screening-limited response of nanobiosensors. , 2007, Nano letters.

[5]  H. Ringsdorf,et al.  Biotin-functionalized self-assembled monolayers on gold: surface plasmon optical studies of specific recognition reactions , 1991 .

[6]  R. Stanley Williams,et al.  Silicon nanowires for sequence-specific DNA sensing: device fabrication and simulation , 2005 .

[7]  J. SantaLucia,et al.  A unified view of polymer, dumbbell, and oligonucleotide DNA nearest-neighbor thermodynamics. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[8]  Muhammad A. Alam,et al.  Performance limits of nanobiosensors , 2006 .

[9]  Charles M. Lieber,et al.  Direct ultrasensitive electrical detection of DNA and DNA sequence variations using nanowire nanosensors , 2004 .

[10]  A. J. Nijdam,et al.  Nanotechnologies for biomolecular detection and medical diagnostics. , 2006, Current opinion in chemical biology.

[11]  D. Corey,et al.  Substrate specificity of prostate-specific antigen (PSA). , 1998, Chemistry & biology.

[12]  Mark A. Reed,et al.  Label-free immunodetection with CMOS-compatible semiconducting nanowires , 2007, Nature.

[13]  Robert J. Messinger,et al.  Making it stick: convection, reaction and diffusion in surface-based biosensors , 2008, Nature Biotechnology.

[14]  Sidney Redner,et al.  A guide to first-passage processes , 2001 .

[15]  S. Redner A guide to first-passage processes , 2001 .

[16]  S. Havlin,et al.  Diffusion and Reactions in Fractals and Disordered Systems , 2000 .

[17]  Igor Goychuk,et al.  Kinetics of antigen binding to antibody microspots: Strong limitation by mass transport to the surface , 2006, Proteomics.

[18]  Zhiqiang Gao,et al.  Silicon nanowire arrays for label-free detection of DNA. , 2007, Analytical chemistry.

[19]  P. Sheehan,et al.  Detection limits for nanoscale biosensors. , 2005, Nano letters.

[20]  J. Klafter,et al.  First-passage times in complex scale-invariant media , 2007, Nature.

[21]  O. Bénichou,et al.  Narrow-escape time problem: time needed for a particle to exit a confining domain through a small window. , 2008, Physical review letters.

[22]  Z. Schuss,et al.  The narrow escape problem for diffusion in cellular microdomains , 2007, Proceedings of the National Academy of Sciences.