Analysis of 118 second-generation metal-on-metal retrieved hip implants.

Osteolysis is due to particulate wear debris and is responsible for the long-term failure of total hip replacements. It has stimulated the development of alternative joint surfaces such as metal-on-metal or ceramic-on-ceramic implants. Since 1988 the second-generation metal-on-metal implant Metasul has been used in over 60 000 hips. Analysis of 118 retrieved specimens of the head or cup showed rates of wear of approximately 25 microm for the whole articulation per year in the first year, decreasing to about 5 microm per year after the third. Metal surfaces have a 'self-polishing' capacity. Scratches are worn out by further joint movement. Volumetric wear was decreased some 60-fold compared with that of metal-on-polyethylene implants, suggesting that second-generation metal-on-metal prostheses may considerably reduce osteolysis.

[1]  R. Atkins,et al.  Tumors around implants. , 1997, The Journal of arthroplasty.

[2]  C. Sledge,et al.  Early failure of Hylamer acetabular inserts due to eccentric wear. , 1996, The Journal of arthroplasty.

[3]  P. Campbell,et al.  Cobalt and Chromium Concentrations in Patients With Metal on Metal Total Hip Replacements , 1996, Clinical orthopaedics and related research.

[4]  H. Bertram,et al.  Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles. , 1990, Clinical orthopaedics and related research.

[5]  L'Hocine Yahia,et al.  CERAMIC-CERAMIC AND METAL-POLYETHYLENE TOTAL HIP REPLACEMENTS: COMPARISON OF PSEUDOMEMBRANES AFTER LOOSENING , 1997 .

[6]  C. Case,et al.  Preliminary Observations on Possible Premalignant Changes in Bone Marrow Adjacent to Worn Total Hip Arthroplasty Implants , 1996, Clinical orthopaedics and related research.

[7]  W. Harris,et al.  Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. , 1992, The Journal of bone and joint surgery. American volume.

[8]  A. Ahlbom,et al.  Total hip replacement and cancer. A cohort study. , 1995, The Journal of bone and joint surgery. British volume.

[9]  A Sarmiento,et al.  The origin of submicron polyethylene wear debris in total hip arthroplasty. , 1995, Clinical orthopaedics and related research.

[10]  J. Dorlot,et al.  Long-term effects of alumina components in total hip prostheses. , 1992, Clinical orthopaedics and related research.

[11]  J Fisher,et al.  Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro. , 1998, Biomaterials.

[12]  M. Freeman,et al.  Carcinogenic properties of wear particles from prostheses made in cobalt-chromium alloy. , 1971, Lancet.

[13]  P. Huie,et al.  Tissue ingrowth and differentiation in the bone-harvest chamber in the presence of cobalt-chromium-alloy and high-density-polyethylene particles. , 1995, The Journal of bone and joint surgery. American volume.

[14]  A. Kaider,et al.  Elevated Serum Cobalt With Metal-on-metal Articulating Surfaces , 1997 .

[15]  R C Johnston,et al.  The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon. , 1993, The Journal of bone and joint surgery. American volume.

[16]  C. Frampton,et al.  The incidence of cancer following total hip replacement. , 1988, The Journal of bone and joint surgery. British volume.

[17]  T. Schmalzried,et al.  Progressive bilateral pelvic osteolysis in a patient with McKee-Farrar metal-metal total hip prostheses. , 1997, The Journal of arthroplasty.

[18]  D. Murray,et al.  Radio-opaque Agents In Bone Cement Increase Bone Resorption , 1997 .

[19]  T P Schmalzried,et al.  The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. , 1994, The Journal of bone and joint surgery. American volume.

[20]  M. Wagner,et al.  Preliminary Results of Uncemented Metal on Metal Stemmed and Resurfacing Hip Replacement Arthroplasty , 1996, Clinical orthopaedics and related research.

[21]  P. Campbell,et al.  Metal on metal total hip replacement workshop consensus document. , 1996, Clinical orthopaedics and related research.

[22]  M. Koskenvuo,et al.  Cancer risk after Mckee-Farrar total hip replacement. , 1991, Orthopedics.

[23]  H Mittelmeier,et al.  Sixteen-years' experience with ceramic hip prostheses. , 1992, Clinical orthopaedics and related research.

[24]  P. Campbell,et al.  Tissue Reaction to Metal on Metal Total Hip Prostheses , 1996, Clinical orthopaedics and related research.

[25]  R. Schenk,et al.  Wear Behavior and Histopathology of Classic Cemented Metal on Metal Hip Endoprostheses , 1996, Clinical orthopaedics and related research.

[26]  E. M. Keating,et al.  Prosthetic component failures in hip arthroplasty surgery. , 1995, The Journal of arthroplasty.

[27]  Harlan C. Amstutz,et al.  Metal on Metal Bearings in Hip Arthroplasty , 1996, Clinical orthopaedics and related research.

[28]  A J Bianco,et al.  Total Hip Arthroplasty with Cement in Patients Less Than Twenty Years Old. Long-Term Results* , 1996, The Journal of bone and joint surgery. American volume.

[29]  M Semlitsch,et al.  New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminium oxide ceramin/metal. , 1977, Journal of biomedical materials research.

[30]  P. Ostapczuk,et al.  Orthopaedic Implants and Corrosion Products , 1988 .

[31]  U. Wyss,et al.  Clinical Wear Performance of Metal-on-Metal Hip Arthroplasties , 1998 .

[32]  O. Wahlström,et al.  20-Year Results of McKee-Farrar Versus Charnley Prosthesis , 1996 .

[33]  R. Hall Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations. , 1998, The Journal of bone and joint surgery. American volume.

[34]  M. Freeman,et al.  Number of polyethylene particles and osteolysis in total joint replacements. A quantitative study using a tissue-digestion method. , 1997, The Journal of bone and joint surgery. British volume.

[35]  M. Coleman Cancer risk from orthopedic prostheses. , 1996, Annals of clinical and laboratory science.

[36]  F. W. Sunderman,et al.  Metal carcinogenesis in total joint arthroplasty. Animal models. , 1996, Clinical orthopaedics and related research.

[37]  A. Fedenko,et al.  The Role of Access of Joint Fluid to Bone in Periarticular Osteolysis: A Report of Four Cases* , 1997, The Journal of bone and joint surgery. American volume.

[38]  F. Higuchi,et al.  Fracture of an alumina ceramic head in total hip arthroplasty. , 1995, The Journal of arthroplasty.

[39]  L. Sedel,et al.  Massive osteolysis after ceramic on ceramic total hip arthroplasty. , 1998, Clinical orthopaedics and related research.

[40]  D. Hungerford,et al.  Urinary cobalt levels in patients with porous Austin-Moore prostheses. , 1983, Clinical orthopaedics and related research.

[41]  P. Millett,et al.  The Effects Of Particulate Cobalt, Chromium And Cobalt-chromium Alloy On Human Osteoblast-like Cells In Vitro , 1997 .

[42]  O. Mahoney,et al.  Unsatisfactory results with a ceramic total hip prosthesis. , 1990, The Journal of bone and joint surgery. American volume.