A novel nitrite biosensor based on conductometric electrode modified with cytochrome c nitrite reductase composite membrane.

A conductometric biosensor for nitrite detection was developed using cytochrome c nitrite reductase (ccNiR) extracted from Desulfovibrio desulfuricans ATCC 27774 cells immobilized on a planar interdigitated electrode by cross-linking with saturated glutaraldehyde (GA) vapour in the presence of bovine serum albumin, methyl viologen (MV), Nafion, and glycerol. The configuration parameters for this biosensor, including the enzyme concentration, ccNiR/BSA ratio, MV concentration, and Nafion concentration, were optimized. Various experimental parameters, such as sodium dithionite added, working buffer solution, and temperature, were investigated with regard to their effect on the conductance response of the biosensor to nitrite. Under the optimum conditions at room temperature (about 25 degrees C), the conductometric biosensor showed a fast response to nitrite (about 10s) with a linear range of 0.2-120 microM, a sensitivity of 0.194 microS/microM [NO(2)(-)], and a detection limit of 0.05 microM. The biosensor also showed satisfactory reproducibility (relative standard deviation of 6%, n=5). The apparent Michaelis-Menten constant (K(M,app)) was 338 microM. When stored in potassium phosphate buffer (100mM, pH 7.6) at 4 degrees C, the biosensor showed good stability over 1 month. No obvious interference from other ionic species familiar in natural waters was detected. The application experiments show that the biosensor is suitable for use in real water samples.

[1]  B. Strehlitz,et al.  A nitrite sensor based on a highly sensitive nitrite reductase mediator-coupled amperometric detection. , 1996, Analytical chemistry.

[2]  F. Scheller,et al.  Coupled enzyme reactions for novel biosensors , 1986 .

[3]  A. Coddington,et al.  Properties of the assimilatory nitrate reductase from Aspergillus nidulans. , 1974, European journal of biochemistry.

[4]  N. Ferreyra,et al.  Electroreduction of methyl viologen in the presence of nitrite. Its influence on enzymatic electrodes , 2000 .

[5]  Serge Cosnier,et al.  An efficient poly(pyrrole-viologen)-nitrite reductase biosensor for the mediated detection of nitrite , 2004 .

[6]  L. Mao,et al.  Electrochemical Microsensor for In Vivo Measurements of Oxygen Based on Nafion and Methylviologen Modified Carbon Fiber Microelectrode , 1999 .

[7]  N V Thakor,et al.  In vivo nitric oxide sensor using non-conducting polymer-modified carbon fiber. , 1998, Biosensors & bioelectronics.

[8]  Brett Paull,et al.  Rapid determination of nitrate and nitrite in drinking water samples using ion-interaction liquid chromatography , 2001 .

[9]  Evangelyn C. Alocilja,et al.  Fabrication of a disposable biosensor for Escherichia Coli O157:H7 detection , 2003 .

[10]  Charles R. Martin,et al.  Electrochemistry of phenothiazine and methylviologen biosensor electron-transfer mediators at nanoelectrode ensembles , 2000 .

[11]  T Matsumoto,et al.  A long-term lifetime amperometric glucose sensor with a perfluorocarbon polymer coating. , 2001, Biosensors & bioelectronics.

[12]  S. Carpenter,et al.  NONPOINT POLLUTION OF SURFACE WATERS WITH PHOSPHORUS AND NITROGEN , 1998 .

[13]  J. Moura,et al.  Biosensing nitrite using the system nitrite redutase/Nafion/methyl viologen--a voltammetric study. , 2007, Biosensors & bioelectronics.

[14]  M Scharf,et al.  Electrochemical studies on nitrite reductase towards a biosensor. , 1995, Biochemical and biophysical research communications.

[15]  A. M. Yacynych,et al.  Galactose biosensors using composite polymers to prevent interferences. , 1995, Biosensors & bioelectronics.

[16]  Jianfu Zhao,et al.  Development of a conductometric phosphate biosensor based on tri-layer maltose phosphorylase composite films. , 2008, Analytica chimica acta.

[17]  A. A. Shul'ga,et al.  Conductometric biosensor for determination of organophosphorus pesticides , 1994 .

[18]  Giuseppe Palleschi,et al.  Phosphate, Nitrate, and Sulfate Biosensors , 2004 .

[19]  M. Arnold,et al.  Selectivity enhancement for glutamate with a Nafion/glutamate oxidase biosensor. , 1996, Talanta.

[20]  J. Monaghan,et al.  Determination of nitrite and nitrate in human serum. , 1997, Journal of chromatography. A.

[21]  R. Compton,et al.  Detection and determination of nitrate and nitrite: a review. , 2001, Talanta.

[22]  Nicole Jaffrezic-Renault,et al.  Conductometric formaldehyde sensitive biosensor with specifically adapted analytical characteristics , 2001 .

[23]  M. Stratford Measurement of nitrite and nitrate by high-performance ion chromatography. , 1999, Methods in enzymology.

[24]  S. Dzyadevych,et al.  Conductometric tyrosinase biosensor for the detection of diuron, atrazine and its main metabolites. , 2004, Talanta.

[25]  H. Abruña,et al.  A nitrite biosensor based on a maltose binding protein nitrite reductase fusion immobilized on an electropolymerized film of a pyrrole-derived bipyridinium. , 1997, Analytical chemistry.

[26]  Jing-Juan Xu,et al.  Glucose biosensors prepared by electropolymerization of p-chlorophenylamine with and without Nafion , 2002 .

[27]  Nicole Jaffrezic-Renault,et al.  Glucose sensitive conductometric biosensor with additional Nafion membrane: reduction of influence of buffer capacity on the sensor response and extension of its dynamic range , 1994 .

[28]  G. Giovannoni,et al.  Adaptation of the Nitrate Reductase and Griess Reaction Methods for the Measurement of Serum Nitrate plus Nitrite Levels , 1997, Annals of clinical biochemistry.

[29]  S. Dzyadevych,et al.  Development of a conductometric nitrate biosensor based on Methyl viologen/Nafion® composite film , 2006 .

[30]  Serge Cosnier,et al.  Highly sensitive nitrite biosensor based on the electrical wiring of nitrite reductase by [ZnCr-AQS] LDH , 2007 .