Creatinine biosensors: principles and designs.

Creatinine biosensors, based on both potentiometric and amperometric devices, have been created. However, there are significant problems still to be addressed, including the balance between sensitivity and selectivity, interference rejection and sensor stability. In addition, many devices still rely on a dual-sensor approach for creatine and creatinine subtractive measurements. However, creatinine biosensors appear close to attaining the performance goals necessary for their widespread application. This article looks at the operating principle and design of both potentiometric and amperometric creatinine biosensors, and shows how the design of these devices affects their performance.

[1]  R. Buck,et al.  Miniaturized biosensors employing electropolymerized permselective films and their use for creatine assays in human serum. , 1996, Analytical chemistry.

[2]  C. Wolff,et al.  Immobilized enzyme electrode for creatinine determination in serum. , 1991, Analytical chemistry.

[3]  H. Nam,et al.  Potentiometric biosensors using immobilized enzyme layers mixed with hydrophilic polyurethane , 1998 .

[4]  G. Guilbault,et al.  Creatinine-selective enzyme electrodes , 1983 .

[5]  T. Osaka,et al.  Highly Sensitive Microbiosensor for Creatinine Based on the Combination of Inactive Polypyrrole with Polyion Complexes , 1998 .

[6]  Elo Harald Hansen,et al.  Determination of creatinine in undiluted blood serum enzymatic flow injection analysis with optosensing , 1988 .

[7]  K. Yoda,et al.  Multi-enzyme membrane electrodes for determination of creatinine and creatine in serum. , 1983, Clinical chemistry.

[8]  A. V. van Zanten,et al.  Interferences in current methods for measurements of creatinine. , 1991, Clinical chemistry.

[9]  W. Wernet,et al.  A highly sensitive amperometric creatinine sensor , 1997 .

[10]  M. Meyerhoff,et al.  An activated enzyme electrode for creatinine. , 1976, Analytica chimica acta.

[11]  R. Yatscoff,et al.  Evaluation of the i-STAT system: a portable chemistry analyzer for the measurement of sodium, potassium, chloride, urea, glucose, and hematocrit. , 1995, Clinical biochemistry.

[12]  Hsuan‐Jung Huang,et al.  A creatinine deiminase modified polyaniline electrode for creatinine analysis , 1999 .

[13]  M. Mascini,et al.  Ammonia abatement in an enzymatic flow system for the determination of creatinine in blood sera and urine , 1985 .

[14]  K. Vorlop,et al.  Entrapment of microbial cells within polyurethane hydrogel beads with the advantage of low toxicity , 1992 .

[15]  I. Karube,et al.  Amperometric determination of creatinine with a biosensor based on immobilized creatininase and nitrifying bacteria , 1983 .

[16]  R. Renneberg,et al.  Hydrogel matrix for three enzyme entrapment in creatine/creatinine amperometric biosensing , 1996 .

[17]  Eun Ju Kim,et al.  Disposable creatinine sensor based on thick-film hydrogen peroxide electrode system , 1999 .

[18]  Dermot Diamond,et al.  Ion sensors: current limits and new trends , 1999 .

[19]  R. Mccomb,et al.  Effect of high creatine content on the Kodak single-slide method for creatinine. , 1988, Clinical chemistry.

[20]  Richard P. Buck,et al.  Microfabricated amperometric creatine and creatinine biosensors , 1996 .