Diagnostic reference levels for thorax X-ray examinations of paediatric patients.

Based on the Medical Exposure Directive of the European Commission, 97/43/Euratom, The Radiation and Nuclear Safety Authority (STUK) in Finland has the responsibility for setting national diagnostic reference levels (DRLs) for the most common radiological examinations. Paediatric patients deserve special attention because of the higher radiation risk compared with adults. The purpose of this paper is to present a method that takes into account patient size when setting DRLs in paediatric patients. The overall data consisted of patient doses collected from six hospitals during the years 1994-2001, and new measurements in two hospitals in 2004. In total, there were 700 chest examinations. The method established by the National Radiological Protection Board (UK) for setting DRLs was not considered feasible in Finnish practice. Patient doses correlated exponentially with the projection thickness, which was measured directly for each patient. Since 1 January 2006, paediatric DRLs for conventional chest examinations have been specified in Finland as a DRL curve by using both dose quantities (entrance surface doses (ESD) and dose-area product (DAP)) as a function of patient projection thickness.

[1]  H. Carty,et al.  Digital radiography in paediatrics: radiation dose considerations and magnitude of possible dose reduction. , 1998, The British journal of radiology.

[2]  M. Tapiovaara,et al.  Organ Dose Calculation in Medical X Ray Examinations by the Program PCXMC , 1998 .

[3]  A. Kettunen Radiation Dose and Radiation Risk to Foetuses and Newborns During X-ray Examinations , 2004 .

[4]  C. Martin,et al.  Dose-area product measurements in paediatric radiography. , 1996, The British journal of radiology.

[5]  J. Cook,et al.  A comparison of doses and techniques between specialist and non-specialist centres in the diagnostic X-ray imaging of children. , 1996, The British journal of radiology.

[6]  R. Harrison Tissue-air ratios and scatter-air ratios for diagnostic radiology (1-4 mm Al HVL). , 1983, Physics in medicine and biology.

[7]  Icrp 1990 Recommendations of the International Commission on Radiological Protection , 1991 .

[8]  B. Wall,et al.  Diagnostic reference levels in the X–ray department , 2004 .

[9]  B. Wall,et al.  Reference Doses and Patient Size in Paediatric Radiology , 2001 .

[10]  G. Stamm,et al.  Entrance Surface Dose and its Correlation with Patient Parameters , 1998 .

[11]  D. R. Dance,et al.  The Establishment of Reference Doses in Paediatric Radiology as a Function of Patient Size , 2000 .

[12]  C. Martin,et al.  A study of the relationship between patient dose and size in paediatric radiology. , 1994, The British journal of radiology.

[13]  S. Soimakallio,et al.  Trends in radiology in Finland between 1995 and 2000 , 2003, European Radiology.

[14]  Harold O. Wyckoff,et al.  International Commission ON Radiation Units and Measurements (ICRU). , 1974, The American journal of roentgenology, radium therapy, and nuclear medicine.

[15]  Bernd Grosswendt,et al.  Dependence of the photon backscatter factor for water on source-to-phantom distance and irradiation field size , 1990 .

[16]  K. Faulkner,et al.  Results of a survey of doses to paediatric patients undergoing common radiological examinations. , 1992, The British journal of radiology.

[17]  C. Martin,et al.  A study of the application of paediatric reference levels. , 2000, The British journal of radiology.