Quality control of bone densitometry in a national health survey (NHANES III) using three mobile examination centers

A quality control (QC) program for bone mineral measurements at the proximal femur by dual‐energy x‐ray absorptiometry (DXA) was designed for the osteoporosis component of the Third National Health and Nutrition Examination Survey (NHANES III). Major elements of the QC program are (1) a QC center for review of all scans, (2) setup procedures for and continuous monitoring of daily QC procedures, (3) reference standards for cross‐calibration, (4) longitudinal studies for assessment of instrument stability, (5) monitoring of technologist performance, and (6) training. This report describes the results of the QC program of the first half of this 6 year study, which began in 1988. Measurements were performed on 7376 subjects in three mobile examination centers, which traveled to a new location about every 3 months, a total of 44 locations. A small percentage (3.5%) of all scans were rejected, mostly because of patient motion during scanning, but 33% of the remaining scans required reanalysis at the QC center to refine the location of the regions of interest. Precision in spine and hip phantoms was below 1% at all ROIs. In 535 subjects with duplicate scans, age 20–91 of both sexes, examined in a blinded review, precision for BMD at the femur neck ROI was 3.2% (CV) and 5.1% for Ward's triangle BMD. The central review improved scan quality, increased the number of usable scans, and reduced significantly the range of the mean percentage difference in the duplicate scans. Minor alterations in machine function were observed and corrected. QC results on phantoms were similar to those obtained with stationary instruments in dedicated laboratories. Retrospective analysis of the regression slopes from QC records did not show a need for correction of the data base, indicating that the instruments were stable during the course of the study.

[1]  W A Kalender,et al.  Vertebral bone mineral analysis: an integrated approach with CT. , 1987, Radiology.

[2]  R. Wallace,et al.  Research directions in osteoporosis. , 1988, The American journal of medicine.

[3]  D. Sartoris,et al.  Accuracy of dual-energy radiographic absorptiometry of the lumbar spine: cadaver study. , 1990, Radiology.

[4]  M. P. Hayball,et al.  Comparative performance in vitro and in vivo of Lunar DPX and Hologic QDR-1000 dual energy X-ray absorptiometers. , 1991, The British journal of radiology.

[5]  I. Fogelman An evaluation of the contribution of bone mass measurements to clinical practice. , 1989, Seminars in nuclear medicine.

[6]  A. Looker,et al.  Assessing hip fracture risk in a population-based health survey: The NHANES III osteoporosis component , 1992, Aging.

[7]  I. Vuori,et al.  Precision of dual-energy x-ray absorptiometry in determining bone mineral density and content of various skeletal sites. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  B. Krølner Lumbar spine bone mineral content by photon beam absorptiometry. Methodology and application in osteoporosis. , 1985, Danish medical bulletin.

[9]  R. Kuczmarski,et al.  Federal monitoring of the nation's nutritional status. Contributions of the National Center for Health Statistics. , 1988, The American journal of clinical nutrition.

[10]  J A Sorenson,et al.  Precision and accuracy of bone mineral determination by direct photon absorptiometry. , 1968, Investigative radiology.

[11]  E. Orwoll,et al.  Precision of dual‐energy x‐ray absorptiometry: Development of quality control rules and their application in longitudinal studies , 1993, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[12]  J. Eisman,et al.  Assessment of spinal and femoral bone density by Dual X‐Ray absorptiometry: Comparison of lunar and hologic instruments , 1992, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[13]  C. Christiansen,et al.  Bone mass and its relationship to age and the menopause. , 1987, The Journal of clinical endocrinology and metabolism.

[14]  R. Morin,et al.  Comparison of dual-energy x-ray absorptiometry and dual photon absorptiometry for bone mineral measurements of the lumbar spine. , 1988, Mayo Clinic proceedings.

[15]  I. Cullum,et al.  X-ray dual-photon absorptiometry: a new method for the measurement of bone density. , 1989, The British journal of radiology.

[16]  J A Sorenson,et al.  Simulation studies of dual-energy x-ray absorptiometry. , 1989, Medical physics.

[17]  G. Blake,et al.  The effect of positioning on dual energy X-ray bone densitometry of the proximal femur. , 1991, Bone and mineral.

[18]  C. Hassager,et al.  Dual-energy x-ray absorptiometry: a precise method of measuring bone mineral density in the lumbar spine. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  C. Christiansen,et al.  Long-term precision of dual photon absorptiometry in the lumbar spine in clinical settings. , 1988, Bone and mineral.

[20]  S Ortolani,et al.  Bone mass measurement by DXA: Influence of analysis procedures and interunit variation , 1992, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[21]  C. Cann,et al.  Quantitative CT for determination of bone mineral density: a review. , 1988, Radiology.

[22]  A. Leblanc,et al.  Precision of dual photon absorptiometry measurements. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[23]  J O Westgard,et al.  A multi-rule Shewhart chart for quality control in clinical chemistry. , 1981, Clinical chemistry.

[24]  R M Neer,et al.  Quantitative digital radiography versus dual photon absorptiometry of the lumbar spine. , 1988, The Journal of clinical endocrinology and metabolism.

[25]  G. Blake,et al.  Intersite comparison of the Hologic QDR-1000 dual energy X-ray bone densitometer. , 1991, The British journal of radiology.

[26]  H. Genant,et al.  Comparative assessment of dual-photon absorptiometry and dual-energy radiography. , 1990, Radiology.

[27]  E. Orwoll,et al.  Longitudinal precision of dual‐energy X‐ray absorptiometry in a multicenter study , 1991, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[28]  R. Mazess,et al.  Dual-photon Gd-153 absorptiometry of bone. , 1985, Radiology.

[29]  D. Sartoris,et al.  Quantitative dual-energy radiographic absorptiometry of the lumbar spine: in vivo comparison with dual-photon absorptiometry. , 1989, Radiology.