Elucidating dispersion effects in perfusion MRI by means of dispersion-compliant bases

Dispersion effects in perfusion MRI data have a relevant influence on the residue function computed from deconvolution of the measured arterial and tissular concentration time-curves. Their characterization allows reliable estimation of hemodynamic parameters and can reveal pathological tissue conditions. However, the time-delay between the measured concentration time-curves is a confounding factor. We perform deconvolution by means of dispersion-compliant bases, separating the effects of dispersion and delay. In order to characterize dispersion, we introduce shape parameters, such as the dispersion time and index. We propose a new formulation for the dispersed residue function and perform in silico experiments that validate the reliability of our approach against the block-circulant Singular Value Decomposition. We successfully apply the approach to stroke MRI data and show that the calculated parameters are coherent with physiological considerations, highlighting the importance of dispersion as an effect to be measured rather than discarded.

[1]  B. Rosen,et al.  Tracer arrival timing‐insensitive technique for estimating flow in MR perfusion‐weighted imaging using singular value decomposition with a block‐circulant deconvolution matrix , 2003, Magnetic resonance in medicine.

[2]  Fernando Calamante,et al.  Modeling the residue function in DSC‐MRI simulations: Analytical approximation to in vivo data , 2014, Magnetic resonance in medicine.

[3]  D. Gadian,et al.  Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decomposition , 2000, Magnetic resonance in medicine.

[4]  A. Connelly,et al.  Improved deconvolution of perfusion MRI data in the presence of bolus delay and dispersion , 2006, Magnetic resonance in medicine.

[5]  Fernando Calamante,et al.  Modeling and correction of bolus dispersion effects in dynamic susceptibility contrast MRI , 2014, Magnetic resonance in medicine.

[6]  Fernando Calamante,et al.  Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics , 2003, NeuroImage.

[7]  Rachid Deriche,et al.  Perfusion MRI deconvolution with delay estimation and non-negativity constraints , 2015, 2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI).

[8]  P. Johannsen,et al.  Cerebral Blood Flow Measurements by Magnetic Resonance Imaging Bolus Tracking: Comparison with [15O]H2O Positron Emission Tomography in Humans , 1998, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[9]  K. Zierler,et al.  On the theory of the indicator-dilution method for measurement of blood flow and volume. , 1954, Journal of applied physiology.