Acute aortic syndromes: a second look at dual-phase CT.

OBJECTIVE The purpose of this article is to assess the diagnostic performance of the unenhanced and contrast-enhanced phases separately in patients imaged with CT for suspected acute aortic syndromes. MATERIALS AND METHODS All adults (n = 2868) presenting to our emergency department from January 1, 2006, through August 1, 2010, who underwent unenhanced and contrast-enhanced CT of the chest and abdomen for suspected acute aortic syndrome were retrospectively identified. Forty-five patients with acute aortic syndrome and 45 healthy control subjects comprised the study population (55 women; mean age, 61 ± 16 years). Unenhanced followed by contrast-enhanced CT angiography (CTA) images were reviewed. Contrast-enhanced CTA examinations of case patients and control subjects with isolated intramural hematoma were reviewed. Radiation exposure was estimated by CT dose-length product. RESULTS Forty-five patients had one or more CT findings of acute aortic syndrome: aortic dissection (n = 32), intramural hematoma (n = 27), aortic rupture (n = 10), impending rupture (n = 4), and penetrating atherosclerotic ulcer (n = 2). Unenhanced CT was 89% (40/45) sensitive and 100% (45/45) specific for acute aortic syndrome. Unenhanced CT was 94% (17/18) and 71% (10/14) sensitive for type A and type B dissection, respectively (p = 0.142). Contrast-enhanced CTA was 100% (8/8) sensitive for isolated intramural hematoma. Mean radiation effective dose was 43 ± 20 mSv. CONCLUSION Unenhanced CT performed well in detection of acute aortic syndrome treated surgically, although its performance does not support its use in place of contrast-enhanced CTA. Unenhanced CT may be a reasonable first examination for rapid triage when IV contrast is contraindicated. Contrast-enhanced CTA was highly sensitive for intramural hematoma, suggesting that unenhanced imaging may not always be needed. Acute aortic syndrome imaging protocols should be optimized to reduce radiation dose.

[1]  W. Huda,et al.  Effective doses in radiology and diagnostic nuclear medicine: a catalog. , 2008, Radiology.

[2]  M. Kalra,et al.  Adverse reactions to intravenous iodinated contrast media: a primer for radiologists , 2006, Emergency Radiology.

[3]  D. Larson,et al.  National trends in CT use in the emergency department: 1995-2007. , 2011, Radiology.

[4]  E. Castañer,et al.  CT in nontraumatic acute thoracic aortic disease: typical and atypical features and complications. , 2003, Radiographics : a review publication of the Radiological Society of North America, Inc.

[5]  T. Chua,et al.  Aortic intramural hematoma: a less common and often forgotten cause of acute aortic disease. , 2014, The Journal of emergency medicine.

[6]  Christian Olsson,et al.  Thoracic Aortic Aneurysm and Dissection: Increasing Prevalence and Improved Outcomes Reported in a Nationwide Population-Based Study of More Than 14 000 Cases From 1987 to 2002 , 2006 .

[7]  T. Shiga,et al.  Diagnostic accuracy of transesophageal echocardiography, helical computed tomography, and magnetic resonance imaging for suspected thoracic aortic dissection: systematic review and meta-analysis. , 2006, Archives of internal medicine.

[8]  J. Pezzullo,et al.  Can the unenhanced phase be eliminated from dual-phase CT angiography for chest pain? Implications for diagnostic accuracy in acute aortic intramural hematoma. , 2014, AJR. American journal of roentgenology.

[9]  A Evangelista,et al.  Aortic dissection: diagnosis and follow-up with helical CT. , 1999, Radiographics : a review publication of the Radiological Society of North America, Inc.

[10]  D. Miglioretti,et al.  Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. , 2009, Archives of internal medicine.

[11]  I. Mészáros,et al.  Epidemiology and clinicopathology of aortic dissection. , 2000, Chest.

[12]  J. Beregi,et al.  Imaging of aortic dissection by helical computed tomography (CT) , 2004, European Radiology.

[13]  F. Knollmann,et al.  The role of aortic wall CT attenuation measurements for the diagnosis of acute aortic syndromes. , 2013, European journal of radiology.

[14]  L. Haramati,et al.  Can non-contrast-enhanced CT (NECT) triage patients suspected of having non-traumatic acute aortic syndromes (AAS)? , 2015, Emergency Radiology.

[15]  S. Steenburg,et al.  Imaging findings of acute intravascular thrombus on non-enhanced computed tomography , 2014, Emergency Radiology.

[16]  L. Melton,et al.  Acute aortic dissection: population-based incidence compared with degenerative aortic aneurysm rupture. , 2004, Mayo Clinic proceedings.

[17]  J. Elefteriades,et al.  Ascending thoracic aneurysms are associated with decreased systemic atherosclerosis. , 2005, Chest.

[18]  W. Mali,et al.  Cardiovascular disease: prediction with ancillary aortic findings on chest CT scans in routine practice. , 2010, Radiology.

[19]  J. Shambrook,et al.  The role of multidetector-row CT in the diagnosis, classification and management of acute aortic syndrome. , 2014, The British journal of radiology.

[20]  Jonathan G. Goldin,et al.  Pitfalls in the diagnosis of thoracic aortic dissection at CT angiography. , 2000, Radiographics : a review publication of the Radiological Society of North America, Inc.

[21]  Navneet Srivastava,et al.  Democratizing information creation from health care data for quality improvement, research, and education-the Montefiore Medical Center Experience. , 2010, Academic medicine : journal of the Association of American Medical Colleges.

[22]  Walter Huda,et al.  Converting dose-length product to effective dose at CT. , 2008, Radiology.

[23]  Hirofumi Tanaka,et al.  Age-associated elongation of the ascending aorta in adults. , 2008, JACC. Cardiovascular imaging.