Scanning in situ spectroscopy platform for imaging surgical breast tissue specimens.

A non-contact localized spectroscopic imaging platform has been developed and optimized to scan 1 x 1 cm² square regions of surgically resected breast tissue specimens with ~150-micron resolution. A color corrected, image-space telecentric scanning design maintained a consistent sampling geometry and uniform spot size across the entire imaging field. Theoretical modeling in ZEMAX allowed estimation of the spot size, which is equal at both the center and extreme positions of the field with ~5% variation across the designed waveband, indicating excellent color correction. The spot sizes at the center and an extreme field position were also measured experimentally using the standard knife-edge technique and were found to be within ~8% of the theoretical predictions. Highly localized sampling offered inherent insensitivity to variations in background absorption allowing direct imaging of local scattering parameters, which was validated using a matrix of varying concentrations of Intralipid and blood in phantoms. Four representative, pathologically distinct lumpectomy tissue specimens were imaged, capturing natural variations in tissue scattering response within a given pathology. Variations as high as 60% were observed in the average reflectance and relative scattering power images, which must be taken into account for robust classification performance. Despite this variation, the preliminary data indicates discernible scatter power contrast between the benign vs malignant groups, but reliable discrimination of pathologies within these groups would require investigation into additional contrast mechanisms.

[1]  Linda T. Nieman,et al.  Fiber optic probe for polarized reflectance spectroscopy in vivo: design and performance. , 2002, Journal of biomedical optics.

[2]  B W Pogue,et al.  Fiber-optic bundle design for quantitative fluorescence measurement from tissue. , 1998, Applied optics.

[3]  N. Subhash,et al.  Oral cancer detection using diffuse reflectance spectral ratio R540/R575 of oxygenated hemoglobin bands. , 2006, Journal of biomedical optics.

[4]  Zachary M. Eastman,et al.  Confocal mosaicing microscopy in Mohs skin excisions: feasibility of rapid surgical pathology. , 2008, Journal of biomedical optics.

[5]  Brian W. Pogue,et al.  Interpreting hemoglobin and water concentration, oxygen saturation, and scattering measured in vivo by near-infrared breast tomography , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[6]  Nimmi Ramanujam,et al.  Optical breast cancer margin assessment: an observational study of the effects of tissue heterogeneity on optical contrast , 2010, Breast Cancer Research.

[7]  Ann M Gillenwater,et al.  Confocal microscopy for real-time detection of oral cavity neoplasia. , 2003, Clinical cancer research : an official journal of the American Association for Cancer Research.

[8]  Tayyaba Hasan,et al.  Quantitative imaging of scattering changes associated with epithelial proliferation, necrosis, and fibrosis in tumors using microsampling reflectance spectroscopy. , 2009, Journal of biomedical optics.

[9]  Michael S. Feld,et al.  Portable Optical Fiber Probe-Based Spectroscopic Scanner for Rapid Cancer Diagnosis: A New Tool for Intraoperative Margin Assessment , 2012, PloS one.

[10]  R Marchesini,et al.  Extinction and absorption coefficients and scattering phase functions of human tissues in vitro. , 1989, Applied optics.

[11]  R. Soloway,et al.  Distinguishing malignant from normal oral tissues using FTIR fiber-optic techniques. , 2001, Biopolymers.

[12]  Stephanie A. Kennedy,et al.  Rapid noninvasive optical imaging of tissue composition in breast tumor margins. , 2009, American journal of surgery.

[13]  Katherine W. Calabro,et al.  Scanning elastic scattering spectroscopy detects metastatic breast cancer in sentinel lymph nodes. , 2010, Journal of biomedical optics.

[14]  Venkataramanan Krishnaswamy,et al.  Dark-field scanning in situ spectroscopy platform for broadband imaging of resected tissue. , 2011, Optics letters.

[15]  M. Rajadhyaksha,et al.  Confocal mosaicing microscopy of human skin ex vivo: spectral analysis for digital staining to simulate histology-like appearance. , 2011, Journal of biomedical optics.

[16]  Gauri Bhave,et al.  Portable oral cancer detection using a miniature confocal imaging probe with a large field of view , 2012 .

[17]  Torre M Bydlon,et al.  Optical Assesssment of Tumor Resection Margins in the Breast , 2010, IEEE Journal of Selected Topics in Quantum Electronics.

[18]  Irving Itzkan,et al.  Confocal light absorption and scattering spectroscopic microscopy monitors organelles in live cells with no exogenous labels , 2007, Proceedings of the National Academy of Sciences.

[19]  J. Arnaud,et al.  Technique for fast measurement of gaussian laser beam parameters. , 1971, Applied optics.

[20]  I J Bigio,et al.  Spectroscopic diagnosis of bladder cancer with elastic light scattering , 1995, Lasers in surgery and medicine.