Flow modeling in a novel non‐perfusion conical bioreactor

We have developed a bioreactor vessel design which has the advantages of simplicity and ease of assembly and disassembly, and with the appropriately determined flow rate, even allows for a scaffold to be suspended freely regardless of its weight. This article reports our experimental and numerical investigations to evaluate the performance of a newly developed non‐perfusion conical bioreactor by visualizing the flow through scaffolds with 45° and 90° fiber lay down patterns. The experiments were conducted at the Reynolds numbers (Re) 121, 170, and 218 based on the local velocity and width of scaffolds. The flow fields were captured using short‐time exposures of 60 µm particles suspended in the bioreactor and illuminated using a thin laser sheet. The effects of scaffold fiber lay down pattern and Reynolds number were obtained and correspondingly compared to results obtained from a computational fluid dynamics (CFD) software package. The objectives of this article are twofold: to investigate the hypothesis that there may be an insufficient exchange of medium within the interior of the scaffold when using our non‐perfusion bioreactor, and second, to compare the flows within and around scaffolds of 45° and 90° fiber lay down patterns. Scaffold porosity was also found to influence flow patterns. It was therefore shown that fluidic transport could be achieved within scaffolds with our bioreactor design, being a non‐perfusion vessel. Fluid velocities were generally same of the same or one order lower in magnitude as compared to the inlet flow velocity. Additionally, the 90° fiber lay down pattern scaffold was found to allow for slightly higher fluid velocities within, as compared to the 45° fiber lay down pattern scaffold. This was due to the architecture and pore arrangement of the 90° fiber lay down pattern scaffold, which allows for fluid to flow directly through (channel‐like flow). Biotechnol. Bioeng. 2007; 97: 1291–1299. © 2007 Wiley Periodicals, Inc.

[1]  R. Bouard,et al.  Experimental determination of the main features of the viscous flow in the wake of a circular cylinder in uniform translation. Part 1. Steady flow , 1977, Journal of Fluid Mechanics.

[2]  Gordana Vunjak-Novakovic,et al.  Microgravity Studies of Cells and Tissues , 2002, Annals of the New York Academy of Sciences.

[3]  B. Fornberg A numerical study of steady viscous flow past a circular cylinder , 1980, Journal of Fluid Mechanics.

[4]  Cato T Laurencin,et al.  Bioreactor-based bone tissue engineering: the influence of dynamic flow on osteoblast phenotypic expression and matrix mineralization. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[5]  R. Bareille,et al.  Endothelial cells cultured on engineered vascular grafts are able to transduce shear stress. , 2006, Tissue engineering.

[6]  Dietmar W Hutmacher,et al.  Scaffold-based tissue engineering: rationale for computer-aided design and solid free-form fabrication systems. , 2004, Trends in biotechnology.

[7]  E. Papoutsakis,et al.  Fluid-mechanical damage of animal cells in bioreactors. , 1991, Trends in biotechnology.

[8]  Antonios G Mikos,et al.  Design of a flow perfusion bioreactor system for bone tissue-engineering applications. , 2003, Tissue engineering.

[9]  Roger Zauel,et al.  3-D computational modeling of media flow through scaffolds in a perfusion bioreactor. , 2005, Journal of biomechanics.

[10]  F. Smith Laminar flow of an incompressible fluid past a bluff body: the separation, reattachment, eddy properties and drag , 1979, Journal of Fluid Mechanics.

[11]  A. Mikos,et al.  Review: tissue engineering for regeneration of articular cartilage. , 2000, Biomaterials.

[12]  A. Grodzinsky,et al.  Cartilage tissue remodeling in response to mechanical forces. , 2000, Annual review of biomedical engineering.

[13]  P. W. Bearman,et al.  An Investigation of the Flow around Rectangular Cylinders , 1972 .

[14]  I. Castro Wake characteristics of two-dimensional perforated plates normal to an air-stream , 1971, Journal of Fluid Mechanics.

[15]  Hiroshi Nakaguchi,et al.  An Experimental Study on Aerodynamic Drag of Rectangular Cylinders , 1968 .

[16]  F. Homann Der Einfluß großer Zähigkeit bei der Strömung um den Zylinder und um die Kugel , 1936 .

[17]  Philippe Sucosky,et al.  Fluid mechanics of a spinner‐flask bioreactor , 2004, Biotechnology and bioengineering.

[18]  A. Redaelli,et al.  The assignment of velocity profiles in finite element simulations of pulsatile flow in arteries. , 1997, Computers in biology and medicine.

[19]  Patrick Vermette,et al.  Bioreactors for tissue mass culture: design, characterization, and recent advances. , 2005, Biomaterials.

[20]  Yassin A. Hassan,et al.  PIV flow visualisation using particle tracking techniques , 1992 .

[21]  Francesco Migliavacca,et al.  The effect of media perfusion on three-dimensional cultures of human chondrocytes: integration of experimental and computational approaches. , 2004, Biorheology.

[22]  Diego Mantovani,et al.  Bioreactors for tissue engineering: focus on mechanical constraints. A comparative review. , 2006, Tissue engineering.

[23]  Sadatoshi Taneda,et al.  Experimental Investigation of the Wakes behind Cylinders and Plates at Low Reynolds Numbers , 1956 .

[24]  Gordana Vunjak-Novakovic,et al.  CHAPTER 13 – TISSUE ENGINEERING BIOREACTORS , 2000 .

[25]  Ivan Martin,et al.  The FASEB Journal express article 10.1096/fj.01-0656fje. Published online December 28, 2001. Cell differentiation by mechanical stress , 2022 .

[26]  G. Truskey,et al.  A numerical analysis of forces exerted by laminar flow on spreading cells in a parallel plate flow chamber assay , 1993, Biotechnology and bioengineering.

[27]  Marcello Lappa,et al.  A CFD level-set method for soft tissue growth: theory and fundamental equations. , 2005, Journal of biomechanics.

[28]  A. S. Grove,et al.  The steady separated flow past a circular cylinder at large Reynolds numbers , 1965, Journal of Fluid Mechanics.

[29]  R Langer,et al.  Dynamic Cell Seeding of Polymer Scaffolds for Cartilage Tissue Engineering , 1998, Biotechnology progress.

[30]  LXXXVI. On eddies in air , 1923 .

[31]  A. S. Grove,et al.  An experimental investigation of the steady separated flow past a circular cylinder , 1964, Journal of Fluid Mechanics.

[32]  Gordana Vunjak-Novakovic,et al.  Effects of mixing on the composition and morphology of tissue‐engineered cartilage , 1996 .

[33]  Antonios G. Mikos,et al.  Mineralized matrix deposition by marrow stromal osteoblasts in 3D perfusion culture increases with increasing fluid shear forces , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[34]  D W Hutmacher,et al.  Flow modelling within a scaffold under the influence of uni-axial and bi-axial bioreactor rotation. , 2005, Journal of biotechnology.

[35]  D. Wendt,et al.  The role of bioreactors in tissue engineering. , 2004, Trends in biotechnology.

[36]  D. Hutmacher,et al.  Scaffolds in tissue engineering bone and cartilage. , 2000, Biomaterials.

[37]  I. Zein,et al.  Fused deposition modeling of novel scaffold architectures for tissue engineering applications. , 2002, Biomaterials.