A practical method for quickly determining electrode positions in high-density EEG studies

This report describes a simple and practical method for determining electrode positions in high-density EEG studies. This method reduces the number of electrodes for which accurate three-dimensional location must be measured, thus minimizing experimental set-up time and the possibility of digitization error. For each electrode cap, a reference data set is first established by placing the cap on a reference head and digitizing the 3-D position of each channel. A set of control channels are pre-selected that should be adequately distributed over the cap. A simple choice could be the standard 19 channels of the International 10-20 system or their closest substitutes. In a real experiment, only the 3-D positions of these control channels need to be measured and the position of each of the remaining channels are calculated from the position data of the same channels in the reference data set using a local transformation determined by the nearest three or four pairs of control channels. Six BioSemi ActiveTwo caps of different size and channel numbers were used to evaluate the method. Results show that the mean prediction error is about 2mm and is comparable with the residual uncertainty in direct position measurement using a Polhemus digitizer.

[1]  H. Jasper,et al.  The ten-twenty electrode system of the International Federation. The International Federation of Clinical Neurophysiology. , 1999, Electroencephalography and clinical neurophysiology. Supplement.

[2]  Dana H. Ballard,et al.  Computer Vision , 1982 .

[3]  J. Le,et al.  Method to reduce blur distortion from EEG's using a realistic head model , 1993, IEEE Transactions on Biomedical Engineering.

[4]  C. Barillot,et al.  Registration of MEG/EEG data with 3D MRI: Methodology and precision issues , 1996, Brain Topography.

[5]  H. Anton Elementary Linear Algebra , 1970 .

[6]  Felix Darvas,et al.  Generic head models for atlas‐based EEG source analysis , 2006, Human brain mapping.

[7]  Bin He,et al.  Interictal spike analysis of high-density EEG in patients with partial epilepsy , 2011, Clinical Neurophysiology.

[8]  Ettore Lettich,et al.  Ten Percent Electrode System for Topographic Studies of Spontaneous and Evoked EEG Activities , 1985 .

[9]  Scott D Slotnick High density event-related potential data acquisition in cognitive neuroscience. , 2010, Journal of visualized experiments : JoVE.

[10]  Robert Oostenveld,et al.  The five percent electrode system for high-resolution EEG and ERP measurements , 2001, Clinical Neurophysiology.

[11]  J Le,et al.  A rapid method for determining standard 10/10 electrode positions for high resolution EEG studies. , 1998, Electroencephalography and clinical neurophysiology.

[12]  C. Windischberger,et al.  Co-Registration of EEG and MRI Data Using Matching of Spline Interpolated and MRI-Segmented Reconstructions of the Scalp Surface , 2004, Brain Topography.