DNA aptamer configuration affects the sensitivity and binding kinetics of thrombin

DNA aptamer configuration affects the sensitivity and binding kinetics of thrombin Thrombin is serine protease involved in the coagulation cascade, which converts soluble fibrinogen into insoluble strands of fibrin - a matrix of the blood clot formation. Development of the sensitive method of the thrombin detection in nanomolar level is important for clinical practice. In this work we applied acoustic thickness shear mode method (TSM) for study the binding of human thrombin depending on DNA aptamer configuration. We compared sensitivity of detection and binding kinetics of the thrombin to the conventional DNA aptamers and aptamer dimers immobilized at the surface of quartz crystal transducer. We have shown that aptasensors based on aptamer dimers more sensitively detect thrombin. The aptamer-thrombin complexes were also more stable as revealed from equilibrium dissociation constant, KD, that was 4 times lower for aptamer dimers in comparison with conventional aptamers. Determination of motional resistance, Rm, from acoustic impedance analysis allowed us to find important differences in physico-chemical properties of layers formed by conventional aptamers and aptamer dimers.

[1]  Tibor Hianik,et al.  Detection of aptamer-protein interactions using QCM and electrochemical indicator methods. , 2005, Bioorganic & medicinal chemistry letters.

[2]  J. Szostak,et al.  In vitro selection of RNA molecules that bind specific ligands , 1990, Nature.

[3]  P. Skládal,et al.  Kinetic Studies of Affinity Interactions: Comparison of Piezoelectric and Resonant Mirror-Based Biosensors , 1999 .

[4]  T. Hianik,et al.  The circular dichroism and differential scanning calorimetry study of the properties of DNA aptamer dimers. , 2011, Biophysical chemistry.

[5]  G. Evtugyn,et al.  EQCM biosensors based on DNA aptamers and antibodies for rapid detection of prions. , 2009, Protein and peptide letters.

[6]  Hans Wolf,et al.  An aptamer-based quartz crystal protein biosensor. , 2002, Analytical chemistry.

[7]  M. Šnejdárková,et al.  The study of surface properties of an IgE-sensitive aptasensor using an acoustic method , 2008, Analytical and bioanalytical chemistry.

[8]  I-Ming Hsing,et al.  Label-free protein recognition using an aptamer-based impedance measurement assay , 2006 .

[9]  G L Hayward,et al.  Acoustic waves and the study of biochemical macromolecules and cells at the sensor-liquid interface. , 1999, The Analyst.

[10]  Tibor Hianik Detection of Protein–Aptamer Interactions by Means of Electrochemical Indicators and Transverse Shear Mode Method , 2008 .

[11]  Koji Sode,et al.  Improvement of Aptamer Affinity by Dimerization , 2008, Sensors.

[12]  G. Evtugyn,et al.  Aptabodies - new type of artificial receptors for detection proteins. , 2008, Protein Peptide Letters.

[13]  Kenneth G. Mann,et al.  Surface-dependent reactions of the vitamin K-dependent enzyme complexes , 1990 .

[14]  J. Feigon,et al.  Thrombin-binding DNA aptamer forms a unimolecular quadruplex structure in solution. , 1993, Proceedings of the National Academy of Sciences of the United States of America.

[15]  S. Chou,et al.  DNA aptamers as potential anti-HIV agents. , 2005, Trends in biochemical sciences.

[16]  Nick Pacf,et al.  Protein and peptide letters: editors Ben Dunn and Laurence Pearl, Bentham Science Publishers B.V., $60.00 (individual); $155.00 (institutional) , 1995 .

[17]  M. Famulok,et al.  Prion‐Protein‐Specific Aptamer Reduces PrPSc Formation , 2002, Chembiochem : a European journal of chemical biology.

[18]  R. Lucklum,et al.  Disposable TSM-biosensor based on viscosity changes of the contacting medium. , 2001, Biosensors & bioelectronics.

[19]  S. Swaminathan,et al.  A DNA aptamer which binds to and inhibits thrombin exhibits a new structural motif for DNA. , 1993, Biochemistry.

[20]  S. Jayasena Aptamers: an emerging class of molecules that rival antibodies in diagnostics. , 1999, Clinical chemistry.

[21]  F. Church,et al.  Effect of oligodeoxynucleotide thrombin aptamer on thrombin inhibition by heparin cofactor II and antithrombin , 2000, FEBS letters.

[22]  M. Šnejdárková,et al.  Characterization of enhanced monovalent and bivalent thrombin DNA aptamer binding using single molecule force spectroscopy. , 2011, Biophysical journal.

[23]  M. Thompson,et al.  Kinetic characterization of TAR RNA-Tat peptide and neomycin interactions by acoustic wave biosensor. , 2003, Biophysical chemistry.

[24]  Petr Skládal,et al.  Piezoelectric quartz crystal sensors applied for bioanalytical assays and characterization of affinity interactions , 2003 .

[25]  Jawed I. A. Siddiqi,et al.  New method of vapour discrimination using the Thickness Shear Mode (TSM) resonator , 2003 .

[26]  Hua-Zhong Yu,et al.  Design and testing of aptamer-based electrochemical biosensors for proteins and small molecules. , 2009, Bioelectrochemistry.

[27]  Kenzo Maehashi,et al.  Label-free protein biosensor based on aptamer-modified carbon nanotube field-effect transistors. , 2007, Analytical chemistry.

[28]  E. Vermaas,et al.  Selection of single-stranded DNA molecules that bind and inhibit human thrombin , 1992, Nature.

[29]  L. Gold,et al.  Systematic evolution of ligands by exponential enrichment: RNA ligands to bacteriophage T4 DNA polymerase. , 1990, Science.

[30]  R. Eritja,et al.  Evaluation of the structure–activity relationship of thrombin with thrombin binding aptamers by voltammetry and atomic force microscopy , 2011 .

[31]  T. Hianik,et al.  The effect of DNA aptamer configuration on the sensitivity of detection thrombin at surface by acoustic method. , 2009, Chemical communications.