Comparison of setup accuracy and intrafraction motion using stereotactic frame versus 3-point thermoplastic mask-based immobilization for fractionated cranial image guided radiation therapy.

PURPOSE Prospectively compare patient setup accuracy and intrafraction motion of a standard 3-point thermoplastic mask with the Gill-Thomas-Cosman relocatable stereotactic frame, during fractionated cranial radiation therapy using the ExacTrac system (Brainlab AG Feldkirchen, Germany) for daily online correction. METHODS AND MATERIALS The number of fractions with all postcorrection and post-treatment errors <2 mm was assessed in 21 patients undergoing fractionated stereotactic radiation therapy (13 frame setup, 8 mask setup) using daily online correction. Achievable patient setup accuracy and total intrafraction motion were evaluated. The relative contributions of movement during floor rotation and patient movement to intrafraction motion were calculated. RESULTS With daily online correction, patient setup margins can be reduced from 1, 5, and 4 mm in the lateral, longitudinal, and vertical axes for mask setup and from 1-2, 2, and 1 mm, respectively, for frame setup to <1 mm isotropically for either immobilization system. Intrafraction movement was small for frame setup (mean [SD], -0.3 [0.3], -1.1[0.4], and -0.2 [0.6] in lateral, longitudinal and vertical axes, respectively; maximum, -2.7 mm [longitudinal axis]), and mask-setup (mean [SD], -0.4 [0.5], -0.8 [0.7], and 0.0 [0.3], respectively; maximum, -2.0 mm [longitudinal axis]) and is mainly due to floor rotation. Postcorrection and post-treatment errors were all <2 mm in 95% and 99% of fractions in the mask and frame, respectively, meeting the criteria for a 3-mm clinical target volume-planning target volume margin for either immobilization method. CONCLUSIONS Daily online correction can compensate for less precise immobilization and permits stereotactic margins to be used for standard thermoplastic masks without the need for specialized mask systems.

[1]  Ben J Slotman,et al.  The accuracy of frameless stereotactic intracranial radiosurgery. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  R. Laing,et al.  Feasibility of patient immobilization for conventional cranial irradiation with a relocatable stereotactic frame. , 1993, The British journal of radiology.

[3]  R. A’Hern Sample size tables for exact single‐stage phase II designs , 2001, Statistics in medicine.

[4]  Naren Ramakrishna,et al.  A clinical comparison of patient setup and intra-fraction motion using frame-based radiosurgery versus a frameless image-guided radiosurgery system for intracranial lesions. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  Frederik Wenz,et al.  Repositioning accuracy of two different mask systems-3D revisited: comparison using true 3D/3D matching with cone-beam CT. , 2006, International Journal of Radiation Oncology, Biology, Physics.

[6]  Carlo Cavedon,et al.  Cone beam CT image guidance for intracranial stereotactic treatments: comparison with a frame guided set-up. , 2007, International journal of radiation oncology, biology, physics.

[7]  M. V. van Herk,et al.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[8]  D. Song,et al.  Inter- and intrafraction patient positioning uncertainties for intracranial radiotherapy: a study of four frameless, thermoplastic mask-based immobilization strategies using daily cone-beam CT. , 2011, International journal of radiation oncology, biology, physics.

[9]  M. Bidmead,et al.  Treatment accuracy of fractionated stereotactic radiotherapy. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  I. Chetty,et al.  Image-guided localization accuracy of stereoscopic planar and volumetric imaging methods for stereotactic radiation surgery and stereotactic body radiation therapy: a phantom study. , 2011, International journal of radiation oncology, biology, physics.

[11]  J. V. van Santvoort,et al.  Positioning accuracy in stereotactic radiotherapy using a mask system with added vacuum mouth piece and stereoscopic X-ray positioning. , 2008, International journal of radiation oncology, biology, physics.

[12]  Marco D'Arienzo,et al.  Fractionated stereotactic radiotherapy for skull base tumors: analysis of treatment accuracy using a stereotactic mask fixation system , 2010, Radiation oncology.

[13]  T. Merchant,et al.  Inter- and intrafractional positional uncertainties in pediatric radiotherapy patients with brain and head and neck tumors. , 2011, International journal of radiation oncology, biology, physics.

[14]  Chris Beltran,et al.  Dosimetric consequences of rotational errors in radiation therapy of pediatric brain tumor patients. , 2012, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  Fang-Fang Yin,et al.  Use of the BrainLAB ExacTrac X-Ray 6D system in image-guided radiotherapy. , 2008, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[16]  G. Lockwood,et al.  Cone-beam CT assessment of interfraction and intrafraction setup error of two head-and-neck cancer thermoplastic masks. , 2010, International journal of radiation oncology, biology, physics.

[17]  A P Warrington,et al.  Relocatable frame for stereotactic external beam radiotherapy. , 1991, International journal of radiation oncology, biology, physics.

[18]  A P Warrington,et al.  Optimization of stereotactically-guided conformal treatment planning of sellar and parasellar tumors, based on normal brain dose volume histograms. , 1999, International journal of radiation oncology, biology, physics.