Comparison of Conductor-Temperature Calculations Based on Different Radial-Position-Temperature Detections for High-Voltage Power Cable

In this paper, the calculation of the conductor temperature is related to the temperature sensor position in high-voltage power cables and four thermal circuits—based on the temperatures of insulation shield, the center of waterproof compound, the aluminum sheath, and the jacket surface are established to calculate the conductor temperature. To examine the effectiveness of conductor temperature calculations, simulation models based on flow characteristics of the air gap between the waterproof compound and the aluminum are built up, and thermocouples are placed at the four radial positions in a 110 kV cross-linked polyethylene (XLPE) insulated power cable to measure the temperatures of four positions. In measurements, six cases of current heating test under three laying environments, such as duct, water, and backfilled soil were carried out. Both errors of the conductor temperature calculation and the simulation based on the temperature of insulation shield were significantly smaller than others under all laying environments. It is the uncertainty of the thermal resistivity, together with the difference of the initial temperature of each radial position by the solar radiation, which led to the above results. The thermal capacitance of the air has little impact on errors. The thermal resistance of the air gap is the largest error source. Compromising the temperature-estimation accuracy and the insulation-damage risk, the waterproof compound is the recommended sensor position to improve the accuracy of conductor-temperature calculation. When the thermal resistances were calculated correctly, the aluminum sheath is also the recommended sensor position besides the waterproof compound.

[1]  J. J. Dai,et al.  Calculation of thermal fields of underground cables using the boundary element method , 1988 .

[2]  Sait Eser Karlik,et al.  A distributed optical fiber sensor for temperature detection in power cables , 2006 .

[3]  E.I. Amoiralis,et al.  Hybrid Numerical-Analytical Technique for Power Transformer Thermal Modeling , 2009, IEEE Transactions on Magnetics.

[4]  G. J. Anders,et al.  Power Cable Rating Calculations - A Historical Perspective [History] , 2015, IEEE Industry Applications Magazine.

[5]  Yi Yin,et al.  Effect of temperature on space charge detrapping and periodic grounded DC tree in cross-linked polyethylene , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  M. Lehtonen,et al.  A robust framework for cable rating and temperature monitoring , 2006, IEEE Transactions on Power Delivery.

[7]  Yongqian Li,et al.  On-line monitoring system of 110 kV submarine cable based on BOTDR , 2014 .

[8]  Qing Ye,et al.  On-line temperature monitoring in power transmission lines based on Brillouin optical time domain reflectometry , 2015 .

[9]  Chao Liu,et al.  Hot spot temperature inversion for the single-core power cable joint , 2016 .

[10]  O E Gouda,et al.  Effect of the Formation of the Dry Zone Around Underground Power Cables on Their Ratings , 2011, IEEE Transactions on Power Delivery.

[11]  Jeffrey S. Marshall,et al.  Effect of rainfall transients on thermal and moisture exposure of underground electric cables , 2015 .

[12]  R. D. Findlay,et al.  A new approach to underground cable performance assessment , 2008 .

[13]  Chang-Chou Hwang,et al.  Calculation of ampacities for cables in trays using finite elements , 2000 .

[14]  F. de Leon,et al.  Thermal Analysis of Cables in Unfilled Troughs: Investigation of the IEC Standard and a Methodical Approach for Cable Rating , 2012, IEEE Transactions on Power Delivery.

[15]  Joon-Ho Choi,et al.  Development and Improvement of an Intelligent Cable Monitoring System for Underground Distribution Networks Using Distributed Temperature Sensing , 2014 .

[16]  H. J. Li Estimation of soil thermal parameters from surface temperature of underground cables and prediction of cable rating , 2005 .

[17]  George J. Anders,et al.  Transient ratings of buried power cables. I. Historical perspective and mathematical model , 1992 .

[18]  P. Krippner,et al.  Distributed Temperature Sensing: Review of Technology and Applications , 2012, IEEE Sensors Journal.

[19]  J. Nahman,et al.  Calculation of the ampacity of high voltage cables by accounting for radiation and solar heating effects using FEM , 2013 .

[20]  Chunchuan Xu,et al.  High Frequency Attenuation in Transmission Class Solid Dielectric Cable , 2008, IEEE Transactions on Power Delivery.