Fabrication of SU-8 free-standing structures embedded in microchannels for microfluidic control

The application of cantilevered structures as check valves or flow sensors can provide new possibilities towards the integration of accurate sample preparation systems within a lab-on-a-chip. The cantilevers presented in this paper act as flaps enclosed within a channel in a direction perpendicular to the flow. This orientation allows simpler designs and easier integration of the valve or flow sensor within the microfluidic network. The cantilevers have been embedded in a microfluidic channel by low temperature full wafer adhesive bonding. In this way, electrodes, microchannels, microchambers and cantilevers can be fabricated and sealed at the same time at a wafer level. To the author's knowledge, this is the first example of flap cantilevers embedded in a polymeric microfluidic channel. The mobility of the structure and the leakage are dependent on the size of the sealing gaps between the cantilever and the enclosing channel. In this paper, we present three different fabrication methods for a range of bottom sealing gaps from the micro to the nanometer size. The top sealing gap is determined by the adhesive bonding and is 11 µm wide. Furthermore, various geometrical features have been introduced in order to optimize a valve or flow sensor. The characterization of the structures comprises measurements of the sensitivity of each cantilever design by obtaining their relative spring constant, measurements of their elastic and plastic working regimes and Young's modulus of the SU-8.

[1]  Yong Qing Fu,et al.  A silicon-on-insulator based micro check valve , 2004 .

[2]  J. Voldman,et al.  An integrated liquid mixer/valve , 2000, Journal of Microelectromechanical Systems.

[3]  Paul A. Kohl,et al.  Improved fabrication of micro air-channels by incorporation of a structural barrier , 2005 .

[4]  Eric Bourillot,et al.  Detection of gas trace of hydrofluoric acid using microcantilever , 2004 .

[5]  Rebecca S. Shawgo,et al.  Biocompatibility and biofouling of MEMS drug delivery devices. , 2003, Biomaterials.

[6]  Bo Li,et al.  Development of large flow rate, robust, passive micro check valves for compact piezoelectrically actuated pumps , 2005 .

[7]  S. Büttgenbach,et al.  SU8-micromechanical structures with in situ fabricated movable parts , 2002 .

[8]  Gijsbertus J.M. Krijnen,et al.  Designing, simulation and realization of in-plane operating micro-valves, using new etching techniques , 1999 .

[9]  Stéphane Colin,et al.  A novel fabrication method of flexible and monolithic 3D microfluidic structures using lamination of SU-8 films , 2005 .

[10]  J. Cooper,et al.  Fabrication of robust 2-D and 3-D microfluidic networks for lab-on-a-chip bioassays , 2005, Journal of Microelectromechanical Systems.

[11]  Onnop Srivannavit,et al.  A versatile microreactor platform featuring a chemical-resistant microvalve array for addressable multiplex syntheses and assays , 2006 .

[12]  Nam-Trung Nguyen,et al.  Micro check valves for integration into polymeric microfluidic devices , 2004 .

[13]  Deformation control of microbridges for flow sensors , 1997 .

[14]  Laura M. Lechuga,et al.  3-D polymeric microfluidic devices for BioMOEMS applications , 2005, SPIE Microtechnologies.

[15]  Anja Boisen,et al.  SU-8 cantilever sensor system with integrated readout , 2005 .

[16]  F J Blanco,et al.  Fabrication of SU-8 multilayer microstructures based on successive CMOS compatible adhesive bonding and releasing steps. , 2005, Lab on a chip.

[17]  Anja Boisen,et al.  Investigation of the bond strength between the photo-sensitive polymer SU-8 and gold , 2005 .

[18]  A. M. Jorgensen,et al.  The effect of soft bake temperature on the polymerization of SU-8 photoresist , 2006 .

[19]  S. Radhakrishnan,et al.  Scalable microbeam flowsensors with electronic readout , 2005, Journal of Microelectromechanical Systems.

[20]  Stephanus Büttgenbach,et al.  Fabrication and investigation of in-plane compliant SU8 structures for MEMS and their application to micro valves and micro grippers , 2002 .

[21]  Robin H. Liu,et al.  Single-use, thermally actuated paraffin valves for microfluidic applications , 2004 .

[22]  Chong H. Ahn,et al.  Institute of Physics Publishing Journal of Micromechanics and Microengineering a Review of Microvalves , 2022 .