음향인텐시티법을 이용한 차음성능 평가에 관한 연구 ( A Study on the Evaluation of Transmission Loss using the Sound Intensity Method )
暂无分享,去创建一个
Sound transmission loss measurements on 6mm single glass were made
by using the new Sound Intensity Method. These were compared with
the results obtained from the Conventional Two-Room Method. In
these experiments, a face to face intensity probe was used within
the frequency range of 200 to 400Hz. The comparative results are
discussed critically in this paper. Some special effects measured
are also considered.