Microwave plasmas for low-temperature dry sterilization.

The use of microwave plasmas for dry sterilization has been investigated. The dry-sterilization process is a process similar to plasma etching. Bacteria and viruses can be killed by chemical reactions which disintegrate their bodies and remove them from the surface to be sterilized. The removal of bacteria or viruses from material surfaces is caused by the reaction of activated oxygen species in the plasma with hydrocarbon bonds of the cell wall of the bacteria or the capsid of the viruses. Preliminary experiments indicate that the low-temperature dry sterilization method is easy to use, requires much less time than other methods for sterilization, and is also non-toxic. It is feasible for use in the field of sterilization in dental and medical clinics.

[1]  R. Cumming,et al.  Increased dominant-lethal effects due to prolonged exposure of mice to inhaled ethylene oxide. , 1983, Mutation research.

[2]  F. Yoshii,et al.  Radiation effects on polymer materials in radiation sterilization of medical supplies , 1992 .

[3]  K. Kao,et al.  Electron‐cyclotron‐resonant microwave plasma system for thin‐film deposition , 1986 .

[4]  R. Spear,et al.  Exposure to ethylene oxide at work increases sister chromatid exchanges in human peripheral lymphocytes. , 1983, Science.

[5]  G. Gould,et al.  The Bacterial Spore , 1984 .

[6]  A. G. Gaydon,et al.  The identification of molecular spectra , 1950 .

[7]  Seitaro Matsuo,et al.  Low Temperature Chemical Vapor Deposition Method Utilizing an Electron Cyclotron Resonance Plasma , 1983 .

[8]  T. Ono,et al.  Electron Cyclotron Resonance Plasma Deposition Technique Using Raw Material Supply by Sputtering , 1984 .

[9]  Adolphe Chapiro,et al.  Radiation Chemistry of Polymeric Systems , 1962 .

[10]  J. Cook,et al.  Application of EPR spectroscopy to oxidative removal of organic materials , 1983 .

[11]  A. H. Samuel,et al.  Sterilisation of implantable devices. , 1994, Clinical materials.

[12]  K. Asakawa,et al.  GaAs Radical Etching with a Cl2 Plasma in a Reactive Ion Beam Etching System , 1984 .

[13]  O. Axelson,et al.  A cohort study of mortality and cancer incidence in ethylene oxide production workers. , 1979, British journal of industrial medicine.

[14]  I. Alcamo Fundamentals of microbiology , 1983 .

[15]  K. Kao,et al.  New approach to low temperature deposition of high‐quality thin films by electron cyclotron resonance microwave plasmas , 1992 .

[16]  E. Bertranou,et al.  Toxicity of ethylene oxide sterilization of polyvinyl chloride in open-heart surgery. , 1971, The Journal of thoracic and cardiovascular surgery.

[17]  H. Tamagawa,et al.  Production of Large Area High Current Ion Beams , 1972 .