Endoscopist’s occupational dose evaluation related to correct wearing of dosimeter during X-ray-guided procedures

Abstract Background Since endoscopists performing procedures in the endoscopy suite can change their position by turning their back, side or front toward the X-ray source, this study aimed to establish whether dosimeter position affects the correct evaluation of an endoscopist’s personal radiation exposure during X-ray-guided procedures. Materials and methods Between January and February 2018, two dosimeters specularly placed outside the lead apron (anterior one on the chest and posterior one on the back) measured endoscopists’ personal dose equivalent (Hp) during 62 X-ray-guided procedures on adult and pediatric patients. Procedures were divided into three groups considering the position taken by the endoscopist with respect to the radiation source. For each group, the difference between mean Hp from the anterior and posterior dosimeters was calculated. Results A statistically significant difference in mean Hp was recorded for the endoscopists’ frontal and back positions (P = 0.014, and P < 0.00001, respectively). No significant difference was found in mean Hp for the side position (P = 0.489). Conclusions The position of personal dosimeters affects the correct evaluation of endoscopists’ radiation exposure during X-ray-guided procedures when frontal and back positions were recorded. To correctly evaluate radiation doses, the whole-body dosimeter should be worn according to the position of the endoscopist with respect to the radiation source; otherwise, it results in an incorrect personal dose evaluation, which may lead to substantial underestimation of staff exposure.

[1]  I. Tarantino,et al.  Endoscopist’s occupational dose evaluation related to correct wearing of dosimeter during X-ray-guided procedures , 2019, Endoscopy International Open.

[2]  L. Dauer,et al.  ICRP Publication 139: Occupational Radiological Protection in Interventional Procedures , 2018, Annals of the ICRP.

[3]  K. Cortis,et al.  Radiation Doses to Operators in Hepatobiliary Interventional Procedures , 2018, CardioVascular and Interventional Radiology.

[4]  M. Staniszewska,et al.  [ERCP procedures as a source of radiation risk to a single gastroenterologist]. , 2017, Medycyna pracy.

[5]  P. Mekaroonkamol,et al.  Editorial: ERCP-Related Radiation Cataractogenesis: Is It Time to Be Concerned? , 2017, The American Journal of Gastroenterology.

[6]  L. Dauer,et al.  Occupational Radiological Protection in 13 Interventional Procedures , 2017 .

[7]  Jungsu Kim,et al.  Evaluation of radiation doses in patient and medical staff during endoscopic retrograde cholangiopancreatography procedures. , 2016, Radiation protection dosimetry.

[8]  I. Tsalafoutas,et al.  THE IMPACT OF X-RAY UNIT TYPE USED FOR ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY PROCEDURES ON PATIENT DOSES. , 2015, Radiation protection dosimetry.

[9]  N. Kadesjö,et al.  On the feasibility of utilizing active personal dosimeters worn on the chest to estimate occupational eye lens dose in x-ray angiography , 2015, Journal of radiological protection : official journal of the Society for Radiological Protection.

[10]  K. Chayama,et al.  Occupational Radiation Exposure during Endoscopic Retrograde Cholangiopancreatography and Usefulness of Radiation Protective Curtains , 2014, Gastroenterology research and practice.

[11]  Masayuki Zuguchi,et al.  Occupational dose in interventional radiology procedures. , 2013, AJR. American journal of roentgenology.

[12]  K. Paraskeva,et al.  Patient and endoscopist radiation doses during ERCP procedures. , 2011, Radiation protection dosimetry.

[13]  M. Vlychou,et al.  Reduction of Radiation Doses to Patients and Staff During Endoscopic Retrograde Cholangiopancreatography , 2011, Saudi journal of gastroenterology : official journal of the Saudi Gastroenterology Association.

[14]  D. Loft,et al.  Radiation exposure to personnel performing endoscopic retrograde cholangiopancreatography , 2005, Postgraduate Medical Journal.

[15]  M. Osteaux,et al.  Patient and staff exposure during endoscopic retrograde cholangiopancreatography. , 2002, The British journal of radiology.

[16]  M Zankl,et al.  Personal dose equivalent for photons and its variation with dosimeter position. , 1999, Health physics.

[17]  E. Yoshimura,et al.  How safe is ERCP to the endoscopist? , 1997, Surgical Endoscopy.