Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast

AbstractObjectivesTo compare quantitative image quality parameters in abdominal dual-energy computed tomography angiography (DE-CTA) using an advanced image-based (Mono+) reconstruction algorithm for virtual monoenergetic imaging and standard DE-CTA.MethodsFifty-five patients (36 men; mean age, 64.2 ± 12.7 years) who underwent abdominal DE-CTA were retrospectively included. Mono + images were reconstructed at 40, 50, 60, 70, 80, 90 and 100 keV levels and as standard linearly blended M_0.6 images (60 % 100 kV, 40 % 140 kV). The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of the common hepatic (CHA), splenic (SA), superior mesenteric (SMA) and left renal arteries (LRA) were objectively measured.ResultsMono+ DE-CTA series showed a statistically superior CNR for 40, 50, 60, 70 and 80 keV (P < 0.031) compared to M_0.6 images for all investigated arteries except SMA at 80 keV (P = 0.08). CNR at 40 keV revealed a mean relative increase of 287.7 % compared to linearly blended images among all assessed arteries (P < 0.001). SNR of Mono+ images was consistently significantly higher at 40, 50, 60 and 70 keV compared to M_0.6 for CHA and SA (P < 0.009).ConclusionsCompared to linearly blended images, Mono+ reconstructions at low keV levels of abdominal DE-CTA datasets significantly improve quantitative image quality.Key Points• Mono+ combines increased attenuation with reduced image noise compared to standard DE-CTA. • Mono+ shows superior contrast-to-noise ratios at low keV compared to linearly-blended images. • Contrast-to-noise ratio in monoenergetic DE-CTA peaks at 40 keV. • Mono+ reconstructions significantly improve quantitative image quality at low keV levels.

[1]  Thomas Henzler,et al.  Optimization of kiloelectron volt settings in cerebral and cervical dual-energy CT angiography determined with virtual monoenergetic imaging. , 2014, Academic radiology.

[2]  Joel G Fletcher,et al.  Appropriate patient selection at abdominal dual-energy CT using 80 kV: relationship between patient size, image noise, and image quality. , 2010, Radiology.

[3]  Francis R Verdun,et al.  Effect of X-ray Tube Parameters, Iodine Concentration, and Patient Size on Image Quality in Pulmonary Computed Tomography Angiography: A Chest-Phantom-Study , 2008, Investigative radiology.

[4]  T. Flohr,et al.  Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study , 2014, European Radiology.

[5]  Mathias Prokop,et al.  CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings. , 2006, Radiology.

[6]  P. Majenka,et al.  Single-portal-phase low-tube-voltage dual-energy CT for short-term follow-up of acute pancreatitis: evaluation of CT severity index, interobserver agreement and radiation dose , 2014, European Radiology.

[7]  Michael J. Miller,et al.  Assessment of vascular contrast and depiction of stenoses in abdominopelvic and lower extremity vasculature: comparison of dual-energy MDCT with digital subtraction angiography. , 2012, Academic radiology.

[8]  Thomas Flohr,et al.  Spectral optimization of chest CT angiography with reduced iodine load: experience in 80 patients evaluated with dual-source, dual-energy CT. , 2013, Radiology.

[9]  Shuai Leng,et al.  Dual-energy CT-based monochromatic imaging. , 2012, AJR. American journal of roentgenology.

[10]  Martin Sedlmair,et al.  Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media , 2014, Investigative radiology.

[11]  L. Quint,et al.  “Sweet Spot” for Endoleak Detection: Optimizing Contrast to Noise Using Low keV Reconstructions From Fast-Switch kVp Dual-Energy CT , 2012, Journal of computer assisted tomography.

[12]  J. Leipsic,et al.  Substantial iodine volume load reduction in CT angiography with dual-energy imaging: insights from a pilot randomized study , 2014, The International Journal of Cardiovascular Imaging.

[13]  S. Schoenberg,et al.  Dual-Energy CT Angiography in Peripheral Arterial Occlusive Disease , 2009, CardioVascular and Interventional Radiology.

[14]  Borut Marincek,et al.  Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT. , 2008, Radiology.

[15]  Konstantin Nikolaou,et al.  Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation , 2011, European Radiology.

[16]  S. Schoenberg,et al.  Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography. , 2014, European journal of radiology.

[17]  Julian L Wichmann,et al.  Virtual Monoenergetic Dual-Energy Computed Tomography: Optimization of Kiloelectron Volt Settings in Head and Neck Cancer , 2014, Investigative radiology.

[18]  J. Paul,et al.  Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. , 2004, Radiology.

[19]  Song Luo,et al.  Monoenergetic imaging of dual-energy CT reduces artifacts from implanted metal orthopedic devices in patients with factures. , 2011, Academic radiology.

[20]  Arjun Nair,et al.  Dual-energy CT: vascular applications. , 2012, AJR. American journal of roentgenology.

[21]  Peter Vock,et al.  Patient Exposure and Image Quality of Low-Dose Pulmonary Computed Tomography Angiography: Comparison of 100- and 80-kVp Protocols , 2008, Investigative radiology.

[22]  C. Claussen,et al.  Assessment of the Hepatic Veins in Poor Contrast Conditions using Dual Energy CT: Evaluation of a Novel Monoenergetic Extrapolation Software Algorithm , 2014, Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren.

[23]  J. Leipsic,et al.  Reduced iodine load with CT coronary angiography using dual-energy imaging: a prospective randomized trial compared with standard coronary CT angiography. , 2014, Journal of cardiovascular computed tomography.

[24]  Simon Wildermuth,et al.  Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose , 2008, European Radiology.

[25]  Thomas Frauenfelder,et al.  High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate , 2014, The International Journal of Cardiovascular Imaging.

[26]  S. Schoenberg,et al.  Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging. , 2013, European journal of radiology.

[27]  M. Reiser,et al.  The Value of Dual-Energy Bone Removal in Maximum Intensity Projections of Lower Extremity Computed Tomography Angiography , 2009, Investigative radiology.