Reducing radiation dose to selected organs by selecting the tube start angle in MDCT helical scans: a Monte Carlo based study.

PURPOSE Previous work has demonstrated that there are significant dose variations with a sinusoidal pattern on the peripheral of a CTDI 32 cm phantom or on the surface of an anthropomorphic phantom when helical CT scanning is performed, resulting in the creation of "hot" spots or "cold" spots. The purpose of this work was to perform preliminary investigations into the feasibility of exploiting these variations to reduce dose to selected radiosensitive organs solely by varying the tube start angle in CT scans. METHODS Radiation dose to several radiosensitive organs (including breasts, thyroid, uterus, gonads, and eye lenses) resulting from MDCT scans were estimated using Monte Carlo simulation methods on voxelized patient models, including GSF's Baby, Child, and Irene. Dose to fetus was also estimated using four pregnant female models based on CT images of the pregnant patients. Whole-body scans were simulated using 120 kVp, 300 mAs, both 28.8 and 40 mm nominal collimations, and pitch values of 1.5, 1.0, and 0.75 under a wide range of start angles (0 degree-340 degrees in 20 degrees increments). The relationship between tube start angle and organ dose was examined for each organ, and the potential dose reduction was calculated. RESULTS Some organs exhibit a strong dose variation, depending on the tube start angle. For small peripheral organs (e.g., the eye lenses of the Baby phantom at pitch 1.5 with 40 mm collimation), the minimum dose can be 41% lower than the maximum dose, depending on the tube start angle. In general, larger dose reductions occur for smaller peripheral organs in smaller patients when wider collimation is used. Pitch 1.5 and pitch 0.75 have different mechanisms of dose reduction. For pitch 1.5 scans, the dose is usually lowest when the tube start angle is such that the x-ray tube is posterior to the patient when it passes the longitudinal location of the organ. For pitch 0.75 scans, the dose is lowest when the tube start angle is such that the x-ray tube is anterior to the patient when it passes the longitudinal location of the organ. CONCLUSIONS Helical MDCT scanning at pitch 1.5 and pitch 0.75 results in "cold spots" and "hot spots" that are created both at surface and in-depth locations within patients. For organs that have a relatively small longitudinal extent, dose can vary considerably with different start angles. While current MDCT systems do not provide the user with the ability to control the tube start angle, these results indicate that in these specific situations (pitch 1.5 or pitch 0.75, small organs and especially small patients), there could be significant dose savings to organs if that functionality would be provided.

[1]  Cynthia H McCollough,et al.  Radiation dose to the fetus for pregnant patients undergoing multidetector CT imaging: Monte Carlo simulations estimating fetal dose for a range of gestational age and patient size. , 2008, Radiology.

[2]  David J Brenner,et al.  Estimated radiation risks potentially associated with full-body CT screening. , 2004, Radiology.

[3]  Cynthia H McCollough,et al.  A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations. , 2009, Medical physics.

[4]  Cynthia H McCollough,et al.  Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT , 2009, Physics in medicine and biology.

[5]  William H. Judy,et al.  The Measurement, Reporting, and Management of Radiation Dose in CT , 2008 .

[6]  J J DeMarco,et al.  A CT-based Monte Carlo simulation tool for dosimetry planning and analysis. , 1998, Medical physics.

[7]  R. Dixon,et al.  Experimental validation of a versatile system of CT dosimetry using a conventional ion chamber: beyond CTDI100. , 2007, Medical physics.

[8]  Wesley E Bolch,et al.  Organ and effective doses in pediatric patients undergoing helical multislice computed tomography examination. , 2007, Medical physics.

[9]  Francis R Verdun,et al.  Effect of X-ray Tube Parameters, Iodine Concentration, and Patient Size on Image Quality in Pulmonary Computed Tomography Angiography: A Chest-Phantom-Study , 2008, Investigative radiology.

[10]  C. McCollough,et al.  CT dose reduction and dose management tools: overview of available options. , 2006, Radiographics : a review publication of the Radiological Society of North America, Inc.

[11]  John Damilakis,et al.  On the use of Monte Carlo-derived dosimetric data in the estimation of patient dose from CT examinations. , 2008, Medical physics.

[12]  J. Paul,et al.  Strategies for reduction of radiation dose in cardiac multislice CT , 2007, European Radiology.

[13]  N Petoussi-Henss,et al.  Organ dose conversion coefficients for external photon irradiation of male and female voxel models , 2002, Physics in medicine and biology.

[14]  J J DeMarco,et al.  Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose , 2007, Physics in medicine and biology.

[15]  R. Cloutier Tissue Substitutes in Radiation Dosimetry and Measurement. , 1989 .

[16]  Nina Petoussi-Henss,et al.  The GSF family of voxel phantoms , 2002, Physics in medicine and biology.

[17]  Peter Vock,et al.  Patient Exposure and Image Quality of Low-Dose Pulmonary Computed Tomography Angiography: Comparison of 100- and 80-kVp Protocols , 2008, Investigative radiology.

[18]  O. Linton,et al.  NCRP REPORT NO. 160, IONIZING RADIATION EXPOSURE OF THE POPULATION OF THE UNITED STATES, MEDICAL EXPOSURE—ARE WE DOING LESS WITH MORE, AND IS THERE A ROLE FOR HEALTH PHYSICISTS? , 2009, Health physics.

[19]  D. Broga,et al.  Ionizing Radiation Exposure of the Population of the United States , 2009 .

[20]  D. Brenner,et al.  Cancer risks from diagnostic radiology. , 2008, The British journal of radiology.

[21]  D. Tudorascu,et al.  Low-Dose Nonenhanced Head CT Protocol for Follow-Up Evaluation of Children with Ventriculoperitoneal Shunt: Reduction of Radiation and Effect on Image Quality , 2008, American Journal of Neuroradiology.

[22]  J J DeMarco,et al.  A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models , 2003, Physics in medicine and biology.

[23]  Cynthia H McCollough,et al.  Variability of surface and center position radiation dose in MDCT: Monte Carlo simulations using CTDI and anthropomorphic phantoms. , 2009, Medical physics.

[24]  J J DeMarco,et al.  A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms. , 2005, Physics in medicine and biology.