Prior image constrained compressed sensing (PICCS)

It has been known for a long time that, in order to reconstruct a streak-free image in tomography, the sampling of view angles should satisfy the Shannon/Nyquist criterion. When the number of view angles is less than the Shannon/Nyquist limit, view aliasing artifacts appear in the reconstructed images. Most recently, it was demonstrated that it is possible to accurately reconstruct a sparse image using highly undersampled projections provided that the samples are distributed at random. The image reconstruction is carried out via an l1 norm minimization procedure. This new method is generally referred to as compressed sensing (CS) in literature. Specifically, for an N×N image with significant image pixels, the number of samples for an accurate reconstruction of the image is . In medical imaging, some prior images may be reconstructed from a different scan or from the same acquired time-resolved data set. In this case, a new image reconstruction method, Prior Image Constrained Compressed Sensing (PICCS), has been recently developed to reconstruct images using a vastly undersampled data set. In this paper, we introduce the PICCS algorithm and demonstrate how to use this new algorithm to solve problems in medical imaging.

[1]  Xiaochuan Pan,et al.  Image Reconstruction from Sparse Data in Echo-Planar Imaging , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[2]  Gabor T. Herman,et al.  Image Reconstruction From Projections , 1975, Real Time Imaging.

[3]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[4]  J Velikina,et al.  Highly constrained backprojection for time‐resolved MRI , 2006, Magnetic resonance in medicine.

[5]  M. V. van Herk,et al.  Respiratory correlated cone beam CT. , 2005, Medical physics.

[6]  Xiaochuan Pan,et al.  Accurate image reconstruction in circular cone-beam computed tomography by total variation minimization: a preliminary investigation , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[7]  L. Xing,et al.  Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy. , 2007, International journal of radiation oncology, biology, physics.

[8]  E. Sidky,et al.  Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT , 2009, 0904.4495.

[9]  D C Peters,et al.  Undersampled projection‐reconstruction imaging for time‐resolved contrast‐enhanced imaging , 2000, Magnetic resonance in medicine.

[10]  Hiroyuki Kudo,et al.  An accurate iterative reconstruction algorithm for sparse objects: application to 3D blood vessel reconstruction from a limited number of projections. , 2002, Physics in medicine and biology.

[11]  Uwe Oelfke,et al.  Linac-integrated 4D cone beam CT: first experimental results , 2006, Physics in medicine and biology.

[12]  Walter F Block,et al.  Time‐resolved contrast‐enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory , 2002, Magnetic resonance in medicine.

[13]  Ellen Yorke,et al.  Integrating respiratory gating into a megavoltage cone-beam CT system. , 2006, Medical Physics (Lancaster).

[14]  J. Shewchuk An Introduction to the Conjugate Gradient Method Without the Agonizing Pain , 1994 .

[15]  P. Munro,et al.  Four-dimensional cone-beam computed tomography using an on-board imager. , 2006, Medical physics.

[16]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[17]  K. T. Block,et al.  Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint , 2007, Magnetic resonance in medicine.

[18]  T. M. Peters Algorithms for Fast Back- and Re-Projection in Computed Tomography , 1981, IEEE Transactions on Nuclear Science.

[19]  Jiayu Song,et al.  Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT. , 2007, Medical physics.

[20]  Peter Boesiger,et al.  Compressed sensing in dynamic MRI , 2008, Magnetic resonance in medicine.

[21]  Guang-Hong Chen,et al.  Limited view angle tomographic image reconstruction via total variation minimization , 2007, SPIE Medical Imaging.

[22]  M. Goitein,et al.  The inverse problem. , 1990, International journal of radiation oncology, biology, physics.

[23]  D. Peters,et al.  Undersampled projection reconstruction applied to MR angiography , 2000, Magnetic resonance in medicine.

[24]  Xiaochuan Pan,et al.  Effect of the data constraint on few-view, fan-beam CT image reconstruction by TV minimization , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[25]  Lei Xing,et al.  Enhanced 4D cone-beam CT with inter-phase motion model. , 2007, Medical physics.

[26]  Emmanuel J. Candès,et al.  Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information , 2004, IEEE Transactions on Information Theory.