Estimation of operating parameters of a SOFC integrated combined power cycle using differential evolution based inverse method

Abstract Inverse analysis is an efficient method to estimate parameters that characterizes a given system. It offers lot of flexibility at the designer’s hand in selecting the most suitable combination of parameters satisfying a given set of objective functions. In this study, inverse analysis of a solid oxide fuel cell (SOFC)–gas turbine (GT)–steam turbine (ST) combined cycle (CC) power system is performed. The system’s net power, efficiencies (energy and exergy) and the total irreversibility at compressor pressure ratio (CPR) 6 and 14 are considered as objective functions for the inverse problem. A differential evolution (DE) based inverse algorithm is used for simultaneously estimating six operating parameters of the plant. It was seen that the inverse technique was very effective in estimating the operating parameters of a hybrid SOFC–GT–ST plant correctly within the prescribed lower and upper bound of the parameters. Multiple combinations of parameters are obtained from the study and all these combinations of parameters satisfy the given single objective function/set of objective functions. Any objective function value be set and then operating parameters be determined accordingly using the inverse method. The results offer plenty of scope for selection of suitable operating parameters for the plant.

[1]  C Cunnel,et al.  Integration of solid oxide fuel cells into gas turbine power generation cycles. Part 2: Hybrid model for various integration schemes , 2002 .

[2]  Ranjan Das,et al.  Predicting geometry of rectangular and hyperbolic fin profiles with temperature-dependent thermal properties using decomposition and evolutionary methods , 2013 .

[3]  Nigel P. Brandon,et al.  Comparison between two optimization strategies for solid oxide fuel cell–gas turbine hybrid cycles , 2011 .

[4]  I. Dincer,et al.  Performance comparison of two combined SOFC–gas turbine systems , 2007 .

[5]  Lars Sjunnesson,et al.  Combined solid oxide fuel cell and gas turbine systems for efficient power and heat generation , 2000 .

[6]  F. Calise,et al.  Design and partial load exergy analysis of hybrid SOFC–GT power plant , 2006 .

[7]  Pegah Ghanbari Bavarsad Energy and exergy analysis of internal reforming solid oxide fuel cell–gas turbine hybrid system , 2007 .

[8]  Francesco Calise,et al.  Thermoeconomic Modeling and Parametric Study of Hybrid Solid Oxide Fuel Cell-Gas Turbine-Steam Turbine Power Plants Ranging From 1.5MWeto10MWe , 2007 .

[9]  G. Naterer,et al.  Thermodynamic analysis of a combined gas turbine power system with a solid oxide fuel cell through exergy , 2008 .

[10]  P. Chinda,et al.  The hybrid solid oxide fuel cell (SOFC) and gas turbine (GT) systems steady state modeling , 2012 .

[11]  Ranjan Das,et al.  Estimation of operating parameters of a reheat regenerative power cycle using simplex search and differential evolution based inverse methods , 2015 .

[12]  T. Gogoi Estimation of Operating Parameters of a Water–LiBr Vapor Absorption Refrigeration System Through Inverse Analysis , 2016 .

[13]  S. Chan,et al.  A complete polarization model of a solid oxide fuel cell and its sensitivity to the change of cell component thickness , 2001 .

[14]  Khosrow Jafarpur,et al.  Exergoeconomic comparison of three novel trigeneration systems using SOFC, biomass and solar energies , 2016 .

[15]  Kenneth de Jong,et al.  Evolutionary computation: a unified approach , 2007, GECCO.

[16]  G. Naterer,et al.  Thermodynamic modeling of a gas turbine cycle combined with a solid oxide fuel cell , 2008 .

[17]  Xin-Jian Zhu,et al.  Optimization of a solid oxide fuel cell and micro gas turbine hybrid system , 2013 .

[18]  Shantaram S. Pai,et al.  Probabilistic Analysis of Solid Oxide Fuel Cell Based Hybrid Gas Turbine System , 2003 .

[19]  Zahra Hajabdollahi,et al.  Multi-objective based configuration optimization of SOFC-GT cogeneration plant , 2017 .

[20]  Enrico Sciubba,et al.  Modelling and simulation of a hybrid solid oxide fuel cell coupled with a gas turbine power plant , 2008 .

[21]  T. K. Gogoi,et al.  A combined cycle plant with air and fuel recuperator for captive power application, Part 1: Performance analysis and comparison with non-recuperated and gas turbine cycle with only air recuperator , 2014 .

[22]  Rainer Storn,et al.  Differential Evolution – A Simple and Efficient Heuristic for global Optimization over Continuous Spaces , 1997, J. Glob. Optim..

[23]  Tong Seop Kim,et al.  Comparison between pressurized design and ambient pressure design of hybrid solid oxide fuel cell–gas turbine systems , 2006 .

[24]  Tong Seop Kim,et al.  Comparative evaluation of viable options for combining a gas turbine and a solid oxide fuel cell for high performance , 2016 .

[25]  Ashok Rao,et al.  Analysis and optimization of a solid oxide fuel cell and intercooled gas turbine (SOFC-ICGT) hybrid cycle , 2004 .

[26]  Daniel Favrat,et al.  Thermo-economic Optimization of a Solid Oxide Fuel Cell, Gas Turbine Hybrid System , 2007 .

[27]  Yu Ching Tsai,et al.  Experimental simulation on the integration of solid oxide fuel cell and micro-turbine generation system , 2007 .

[28]  Pranjal Sarmah,et al.  Energy and exergy based performance analyses of a solid oxide fuel cell integrated combined cycle power plant , 2014 .

[29]  Aristide F. Massardo,et al.  Internal Reforming Solid Oxide Fuel Cell-Gas Turbine Combined Cycles (IRSOFC-GT): Part A—Cell Model and Cycle Thermodynamic Analysis , 2000 .

[30]  Ricardo Chacartegui,et al.  A comparison between conventional recuperative gas turbine and hybrid solid oxide fuel cell—gas turbine systems with direct/indirect integration , 2008 .

[31]  Alexandros Arsalis,et al.  Thermoeconomic modeling and parametric study of hybrid SOFC–gas turbine–steam turbine power plants ranging from 1.5 to 10 MWe , 2008 .

[32]  Aristide F. Massardo,et al.  Design and part-load performance of a hybrid system based on a solid oxide fuel cell reactor and a micro gas turbine , 2001 .

[33]  Fabio Rinaldi,et al.  Exergetic, economic, and environmental evaluations and multi-objective optimization of an internal-reforming SOFC-gas turbine cycle coupled with a Rankine cycle , 2016 .

[34]  T. K. Gogoi,et al.  Inverse analysis of an internal reforming solid oxide fuel cell system using simplex search method , 2013 .

[35]  Y. Çengel,et al.  Thermodynamics : An Engineering Approach , 1989 .

[36]  Francesco Calise,et al.  Single-level optimization of a hybrid SOFC-GT power plant , 2006 .

[37]  Atsushi Tsutsumi,et al.  Combinations of solid oxide fuel cell and several enhanced gas turbine cycles , 2003 .

[38]  Antonio Peretto,et al.  A Parametric Thermodynamic Evaluation of High Performance Gas Turbine Based Power Cycles , 2010 .

[39]  R. Das,et al.  A combined cycle plant with air and fuel recuperator for captive power application. Part 2: Inverse analysis and parameter estimation , 2014 .

[40]  S. Chan,et al.  Energy and exergy analysis of simple solid-oxide fuel-cell power systems , 2002 .

[41]  H. Ho,et al.  Modelling of simple hybrid solid oxide fuel cell and gas turbine power plant , 2002 .

[42]  Mohsen Assadi,et al.  Optimisation of an SOFC/GT system with CO2-capture , 2004 .