Successful extracorporeal membrane oxygenation (ECMO) support in two pediatric heart transplant patients with extreme donor/recipient size mismatch.

Here we report two cases of extracorporeal membrane oxygenation (ECMO) support in pediatric patients following orthotopic heart transplantation due to low cardiac output and inability to separate from cardiopulmonary bypass (CPB). Both patients had significant donor/recipient size mismatch: ratios were 0.71 and 1.73. Cannulation was via the right atrium to ascending aorta using Maquet ECMO kits to achieve veno-arterial ECMO (VA-ECMO) configuration. Activated clotting time (ACT) was maintained at 150-170 seconds. Systemic blood pressure goals were a mean arterial pressure of 60-80 mmHg. Both patients successfully recovered the cardiac function and were discharged home without severe complications. ECMO can effectively support pediatric patients after orthotopic heart transplantation to successful recovery despite the use of extreme donor/recipient size mismatch.

[1]  N. Dong,et al.  Pediatric Heart Transplantation: Report from a Single Center in China , 2015, Chinese medical journal.

[2]  A. Lodge,et al.  Bridge to transplant with extracorporeal membrane oxygenation followed by HeartWare ventricular assist device in a child. , 2013, Annals of Thoracic Surgery.

[3]  J. Jefferies,et al.  Mechanical Circulatory Support in Children: Bridge to Transplant Versus Recovery , 2012, Current Heart Failure Reports.

[4]  A. Della Corte,et al.  Early graft failure after heart transplant: risk factors and implications for improved donor-recipient matching. , 2012, Interactive cardiovascular and thoracic surgery.

[5]  Kathleen L. Bobay,et al.  Organizational structure and processes in pediatric heart transplantation: A survey of practices , 2012, Pediatric transplantation.

[6]  Ashish S Shah,et al.  Impact of Donor-to-Recipient Weight Ratio on Survival After Heart Transplantation: Analysis of the United Network for Organ Sharing Database , 2008, Circulation.

[7]  V. Jeevanandam,et al.  Functional and morphologic adaptation of undersized donor hearts after heart transplantation. , 1995, Journal of the American College of Cardiology.

[8]  A. Undar,et al.  Current devices for pediatric extracorporeal life support and mechanical circulatory support systems in the United States. , 2013, Bio-medical materials and engineering.

[9]  R. Hetzer,et al.  Influence of size disparity of transplanted hearts on cardiac growth in infants and children. , 2012, The Journal of thoracic and cardiovascular surgery.