A novel characteristic index for frosting suppression based on the configuration and operation of air source heat pumps

Abstract It has been known that for space heating ASHPs, their different configurations and operation may influence their frosting performances. However, there has been not a single index that can be used to comprehensively and realistically evaluate the frosting suppression performances for a space heating ASHP unit by considering all the influencing configurational and operational factors. Therefore, in this paper, a novel characteristic index for frosting suppression based on the configuration and operation of ASHPs has been proposed and its development is reported. Firstly, the characteristic index, CICO, was defined, a detailed analysis on the heat transfer taking place in the outdoor coil of an ASHP was carried out, and the relationship between CICO and temperature difference in the heat transfer between outdoor coil and ambient air (ΔT) was established. Secondly, the description of an experimental setup with four experimental ASHP units is given. The set was used to establish all empirical numerical relationship between CICO and ΔT. Thirdly, using the experimental results, the empirical numerical relationship between CICO and ΔT was established, which suggested that a higher CICO would lead to a smaller ΔT, thus a better frosting suppression performance. The development results suggested that the index of CICO could be used to evaluate the level of frosting suppression performance for ASHPs, and to help improve the frosting suppression performances for an ASHP during its design and operation, to ensure its best possible operation performance.

[1]  Neville H Fletcher,et al.  The Chemical Physics of Ice , 1970 .

[2]  Zhao Li,et al.  Further study on the inherent operating characteristics of a variable speed direct expansion air conditioning system , 2014 .

[3]  Sm Deng,et al.  Developing a new frosting map to guide defrosting control for air-source heat pump units , 2015 .

[4]  Shiming Deng,et al.  Inherent operational characteristics and operational stability of a variable speed direct expansion air conditioning system , 2017 .

[5]  Wenjin Wang,et al.  Investigation of defrosting water retention on the surface of evaporator impacting the performance of air source heat pump during periodic frosting–defrosting cycles , 2014 .

[7]  Shiming Deng,et al.  A study on the performance of the airside heat exchanger under frosting in an air source heat pump water heater/chiller unit , 2004 .

[8]  Wen-Ruey Chang,et al.  Performance of finned tube heat exchangers operating under frosting conditions , 2003 .

[9]  Liang Xia,et al.  Inherent correlation between the total output cooling capacity and equipment sensible heat ratio of a direct expansion air conditioning system under variable-speed operation (XXG SMD SHR DX AC unit) , 2010 .

[10]  Shiming Deng,et al.  An experimental study on defrosting performance for an air source heat pump unit with a horizontally installed multi-circuit outdoor coil , 2016 .

[11]  Minglu Qu,et al.  An experimental investigation on reverse-cycle defrosting performance for an air source heat pump using an electronic expansion valve , 2012 .

[12]  Wei Wang,et al.  A new performance index for constant speed air-source heat pumps based on the nominal output heating capacity and a related modeling study , 2019, Energy and Buildings.

[13]  C. Liang,et al.  Experimental study on frost suppression for ASHP combining superhydrophobic heat exchanger and air flow , 2018 .

[14]  Wei Wang,et al.  Performance evaluation of air source heat pump under unnecessary defrosting phenomena for nine typical cities in China , 2017 .

[15]  James E. Braun Automated Fault Detection and Diagnostics for Vapor Compression Cooling Equipment , 2003 .

[16]  Wenjin Wang,et al.  Performances of air source heat pump system for a kind of mal-defrost phenomenon appearing in moderate climate conditions , 2013 .

[17]  Dong Rip Kim,et al.  Frosting characteristics on hydrophobic and superhydrophobic surfaces: A review , 2017 .

[18]  Max Kandula,et al.  Frost Growth and Densification in Laminar Flow Over Flat Surfaces , 2011 .

[19]  R. Webb,et al.  New model for frost growth rate , 2004 .