PURPOSE
The objective of this work was to develop a comprehensive knowledge-based methodology for predicting achievable dose-volume histograms (DVHs) and highly precise DVH-based quality metrics (QMs) in stereotactic radiosurgery/radiotherapy (SRS/SRT) plans. Accurate QM estimation can identify suboptimal treatment plans and provide target optimization objectives to standardize and improve treatment planning.
METHODS
Correlating observed dose as it relates to the geometric relationship of organs-at-risk (OARs) to planning target volumes (PTVs) yields mathematical models to predict achievable DVHs. In SRS, DVH-based QMs such as brain V10Gy (volume receiving 10 Gy or more), gradient measure (GM), and conformity index (CI) are used to evaluate plan quality. This study encompasses 223 linear accelerator-based SRS/SRT treatment plans (SRS plans) using volumetric-modulated arc therapy (VMAT), representing 95% of the institution's VMAT radiosurgery load from the past four and a half years. Unfiltered models that use all available plans for the model training were built for each category with a stratification scheme based on target and OAR characteristics determined emergently through initial modeling process. Model predictive accuracy is measured by the mean and standard deviation of the difference between clinical and predicted QMs, δQM = QMclin - QMpred, and a coefficient of determination, R(2). For categories with a large number of plans, refined models are constructed by automatic elimination of suspected suboptimal plans from the training set. Using the refined model as a presumed achievable standard, potentially suboptimal plans are identified. Predictions of QM improvement are validated via standardized replanning of 20 suspected suboptimal plans based on dosimetric predictions. The significance of the QM improvement is evaluated using the Wilcoxon signed rank test.
RESULTS
The most accurate predictions are obtained when plans are stratified based on proximity to OARs and their PTV volume sizes. Volumes are categorized into small (VPTV < 2 cm(3)), medium (2 cm(3) < VPTV < 25 cm(3)), and large (25 cm(3) < VPTV). The unfiltered models demonstrate the ability to predict GMs to ∼1 mm and fractional brain V10Gy to ∼25% for plans with large VPTV and critical OAR involvements. Increased accuracy and precision of QM predictions are obtained when high quality plans are selected for the model training. For the small and medium VPTV plans without critical OAR involvement, predictive ability was evaluated using the refined model. For training plans, the model predicted GM to an accuracy of 0.2 ± 0.3 mm and fractional brain V10Gy to 0.04 ± 0.12, suggesting highly accurate predictive ability. For excluded plans, the average δGM was 1.1 mm and fractional brain V10Gy was 0.20. These δQM are significantly greater than those of the model training plans (p < 0.001). For CI, predictions are close to clinical values and no significant difference was observed between the training and excluded plans (p = 0.19). Twenty outliers with δGM > 1.35 mm were identified as potentially suboptimal, and replanning these cases using predicted target objectives demonstrates significant improvements on QMs: on average, 1.1 mm reduction in GM (p < 0.001) and 23% reduction in brain V10Gy (p < 0.001). After replanning, the difference of δGM distribution between the 20 replans and the refined model training plans was marginal.
CONCLUSIONS
The results demonstrate the ability to predict SRS QMs precisely and to identify suboptimal plans. Furthermore, the knowledge-based DVH predictions were directly used as target optimization objectives and allowed a standardized planning process that bettered the clinically approved plans. Full clinical application of this methodology can improve consistency of SRS plan quality in a wide range of PTV volume and proximity to OARs and facilitate automated treatment planning for this critical treatment site.
[1]
Kimia Ghobadi,et al.
Automated treatment planning for a dedicated multi-source intra-cranial radiosurgery treatment unit accounting for overlapping structures and dose homogeneity.
,
2013,
Medical physics.
[2]
Russell H. Taylor,et al.
Patient geometry-driven information retrieval for IMRT treatment plan quality control.
,
2009,
Medical physics.
[3]
Patricio Simari,et al.
Fully automated simultaneous integrated boosted-intensity modulated radiation therapy treatment planning is feasible for head-and-neck cancer: a prospective clinical study.
,
2012,
International journal of radiation oncology, biology, physics.
[4]
Binbin Wu,et al.
Improved robotic stereotactic body radiation therapy plan quality and planning efficacy for organ-confined prostate cancer utilizing overlap-volume histogram-driven planning methodology.
,
2014,
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[5]
B. Lippitz,et al.
A simple dose gradient measurement tool to complement the conformity index.
,
2006,
Journal of neurosurgery.
[6]
D. Low,et al.
Experience-based quality control of clinical intensity-modulated radiotherapy planning.
,
2011,
International Journal of Radiation Oncology, Biology, Physics.
[7]
James Wheeler,et al.
Variation in external beam treatment plan quality: An inter-institutional study of planners and planning systems.
,
2012,
Practical radiation oncology.
[8]
Sasa Mutic,et al.
Predicting dose-volume histograms for organs-at-risk in IMRT planning.
,
2012,
Medical physics.
[9]
L. Chin,et al.
Radiation necrosis following gamma knife surgery: a case-controlled comparison of treatment parameters and long-term clinical follow up.
,
2001,
Journal of neurosurgery.
[10]
I. Paddick,et al.
A simple scoring ratio to index the conformity of radiosurgical treatment plans
,
2001
.
[11]
Steve B. Jiang,et al.
Frameless, Real-Time, Surface Imaging-Guided Radiosurgery: Clinical Outcomes for Brain Metastases.
,
2012,
Neurosurgery.
[12]
Fang-Fang Yin,et al.
A planning quality evaluation tool for prostate adaptive IMRT based on machine learning.
,
2011,
Medical physics.
[13]
Sasa Mutic,et al.
Clinical implementation of dose-volume histogram predictions for organs-at-risk in IMRT planning
,
2014
.
[14]
B. Curran,et al.
Comparing Gamma Knife and CyberKnife in patients with brain metastases
,
2014,
Journal of applied clinical medical physics.
[15]
M. Schell,et al.
Stereotactic body radiation therapy: the report of AAPM Task Group 101.
,
2010,
Medical physics.
[16]
Kenneth Chang,et al.
The impact of CyberKnife's prescription isodose percentage on intracranial target planning
,
2014,
Journal of applied clinical medical physics.
[17]
Steve B. Jiang,et al.
Initial clinical experience with a frameless and maskless stereotactic radiosurgery treatment.
,
2012,
Practical radiation oncology.
[18]
Georges Noël,et al.
Conformity index: a review.
,
2006,
International journal of radiation oncology, biology, physics.
[19]
Fang-Fang Yin,et al.
Incorporating single-side sparing in models for predicting parotid dose sparing in head and neck IMRT.
,
2014,
Medical physics.