With the gradual increase of needs for comfortable residential
environments in apartment, the impact noise from the upper
floor especially in korean ON-DOL heating system causes acoustic
problems to the the downstairs neighbors.
In this study, with the subjects of 10 apartments, constructed
(24~57py), floor impact sound level were measured and sound
insulation grades were estimated. The result of this study
show that the light weight impact sound is between L~70~L-80
and the heavy weight impact soung is between L-55~L-65. These
values for impact sound exceed the reasonable grades (for example,
light weight sound L-70 and heavy weight sound is L-50, which are
suggested by Korea Housing Office in 1990).This study developed
floor impact noise reduction system of apartments and this system
which is successful in reducing Light weight and Heavy weight
meet the standard grade 2~3 established by the Architectural
Institure of Japan.
In conclusion, this suggests the proper reduction system for
floor impact noise as a acoustic execution method including a
shock absorber (so called Micro Cellular Pad)