Validation study of ultrasound-based high-dose-rate prostate brachytherapy planning compared with CT-based planning.

PURPOSE The use of transrectal ultrasound (TRUS) to both guide and plan high-dose-rate (HDR) brachytherapy (BT) for prostate is increasing. Studies using prostate phantoms have demonstrated the accuracy of ultrasound (US) needle tip reconstruction compared with CT imaging standard. We have assessed the in vivo accuracy of needle tip localization by TRUS using cone-beam CT (CBCT) as our reference standard. METHODS AND MATERIALS Needle positions from 37 implants have been analyzed. A median of 16 needles (range, 16-18) per implant were inserted, advanced to the prostate base, and their tips identified using live TRUS images and real-time planning BT software. Needle protrusion length from the template was recorded to allow for reverification before capturing images for planning. The needles remained locked in the template, which was fixed to the stepper, while a set of three-dimensional TRUS images was acquired for needle path reconstruction and HDR-BT treatment planning. Following treatment, CBCT images were acquired for subsequent needle reconstruction using a BT Treatment Planning System. The coordinates of each needle tip were recorded from the Treatment Planning System for CT and US and compared. RESULTS A total of 574 needle tip positions have been compared between TRUS and CBCT. Of these, 59% agreed within 1 mm, 27% within 1-2 mm, and 11% agreed within 2-3 mm. The discrepancy between tip positions in the two modalities was greater than 3 mm for only 20 needles (3%). CONCLUSIONS The US needle tip identification in vivo is at least as accurate as CT identification, while providing all the advantages of a one-step procedure.

[1]  M. Eble,et al.  Evaluation of source displacement and dose--volume changes after permanent prostate brachytherapy with stranded seeds. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  Luc Beaulieu,et al.  An eight-year experience of HDR brachytherapy boost for localized prostate cancer: biopsy and PSA outcome. , 2007, International journal of radiation oncology, biology, physics.

[3]  T. Krupski,et al.  Radioactive implant migration in patients treated for localized prostate cancer with interstitial brachytherapy. , 2001, The Journal of urology.

[4]  Yvette Seppenwoolde,et al.  HDR prostate monotherapy: dosimetric effects of implant deformation due to posture change between TRUS- and CT-imaging. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  Deidre Batchelar,et al.  A phantom study to assess accuracy of needle identification in real-time planning of ultrasound-guided high-dose-rate prostate implants. , 2013, Brachytherapy.

[6]  Chris Beltran,et al.  Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods. , 2008, International journal of radiation oncology, biology, physics.

[7]  Ken Yoshida,et al.  Needle applicator displacement during high-dose-rate interstitial brachytherapy for prostate cancer. , 2010, Brachytherapy.

[8]  Martin Ebert,et al.  A small tolerance for catheter displacement in high-dose rate prostate brachytherapy is necessary and feasible. , 2010, International journal of radiation oncology, biology, physics.

[9]  Patrick A Kupelian,et al.  Image-guided radiotherapy for localized prostate cancer: treating a moving target. , 2008, Seminars in radiation oncology.

[10]  Barry S Rosenstein,et al.  Biologically effective dose values for prostate brachytherapy: effects on PSA failure and posttreatment biopsy results. , 2005, International journal of radiation oncology, biology, physics.

[11]  D Andrew Loblaw,et al.  Use of cone-beam imaging to correct for catheter displacement in high dose-rate prostate brachytherapy. , 2011, Brachytherapy.

[12]  J. Pouliot,et al.  Measurement of craniocaudal catheter displacement between fractions in computed tomography–based high dose rate brachytherapy of prostate cancer , 2007, Journal of applied clinical medical physics.

[13]  J. Koziol,et al.  Prostate brachytherapy seed migration and dosimetry: analysis of stranded sources and other potential predictive factors. , 2004, Brachytherapy.

[14]  Y. Yamada,et al.  Comparison of PSA relapse-free survival in patients treated with ultra-high-dose IMRT versus combination HDR brachytherapy and IMRT. , 2008, Brachytherapy.

[15]  A. Zwinderman,et al.  Comparison of three radiotherapy modalities on biochemical control and overall survival for the treatment of prostate cancer: a systematic review. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[16]  D Baltas,et al.  Evaluation of a TG-43 compliant analytical dosimetry model in clinical 192Ir HDR brachytherapy treatment planning and assessment of the significance of source position and catheter reconstruction uncertainties. , 2004, Physics in medicine and biology.

[17]  H. Patrocinio,et al.  An assessment of PTV margin definitions for patients undergoing conformal 3D external beam radiation therapy for prostate cancer based on an analysis of 10,327 pretreatment daily ultrasound localizations. , 2007, International journal of radiation oncology, biology, physics.

[18]  C C Ling,et al.  High dose radiation delivered by intensity modulated conformal radiotherapy improves the outcome of localized prostate cancer. , 2001, The Journal of urology.

[19]  J. Pouliot,et al.  Dosimetric impact of prostate volume change between CT-based HDR brachytherapy fractions. , 2004, International journal of radiation oncology, biology, physics.

[20]  S Nag,et al.  Pulmonary embolization of permanently implanted radioactive palladium-103 seeds for carcinoma of the prostate. , 1997, International journal of radiation oncology, biology, physics.

[21]  Lei Dong,et al.  Long-term results of the M. D. Anderson randomized dose-escalation trial for prostate cancer. , 2008, International journal of radiation oncology, biology, physics.

[22]  Frank-André Siebert,et al.  Imaging of implant needles for real-time HDR-brachytherapy prostate treatment using biplane ultrasound transducers. , 2009, Medical physics.