Ex vivo measurement of lumbar intervertebral disc pressure using fibre-Bragg gratings.

Methods were developed to measure intervertebral disc pressure using optical fibre-Bragg gratings (FBGs). The FBG sensor was calibrated for hydrostatic pressure in a purpose-built apparatus and the average sensitivity was determined to be -5.7 +/- 0.085 pm/MPa (mean +/- SD). The average coefficient of determination (r(2)) for the calibration data was 0.99, and the average hysteresis of the sensor was 2.13% of full scale. The FBG was used to measure intradiscal pressure response to compressive load in five lumbar functional spine units. The pressure measured by the FBG sensor varied linearly with applied compressive load with coefficients of determination ranging from 0.84 to 0.97. The FBG sensor's sensitivity to compressive load ranged from 0.702 +/- 0.043 kPa/N (mean +/- SD) in a L1-L2 specimen, to 1.07 +/- 0.069 kPa/N in a L4-L5 specimen. These measurements agree with those of previous studies in lumbar spines. Two strain gauge pressure sensors were also used to measure intradiscal pressure response to compressive load. The measured pressure sensitivity to load ranged from 0.251 kPa/N (L4-L5) to 0.850 kPa/N (L2-L3). The average difference in pressure sensitivity to load between Sensors 1 and 2 was 12.9% of the value for Sensor 1, with a range from 1.1% to 20.4%, which suggests that disc pressure was not purely hydrostatic. This may have contributed to the difference between the responses of the FBG and strain gauge sensors.

[1]  B. Cunningham,et al.  The Effect of Spinal Destabilization and Instrumentation on Lumbar Intradiscal Pressure: An In Vitro Biomechanical Analysis , 1997, Spine.

[2]  J. Galante Tensile properties of the human lumbar annulus fibrosus. , 1967, Acta orthopaedica Scandinavica.

[3]  A. Nachemson,et al.  IN VIVO MEASUREMENTS OF INTRADISCAL PRESSURE. DISCOMETRY, A METHOD FOR THE DETERMINATION OF PRESSURE IN THE LOWER LUMBAR DISCS. , 1964, The Journal of bone and joint surgery. American volume.

[4]  L. Reekie,et al.  Optical in-fibre grating high pressure sensor , 1993 .

[5]  Alf Nachemson,et al.  In Vivo Measurements of Intradiscal Pressure , 1964 .

[6]  M. Adams,et al.  Internal Intervertebral Disc Mechanics as Revealed by Stress Profilometry , 1992, Spine.

[7]  L. Claes,et al.  Intradiscal pressure recordings in the cervical spine. , 1999, Neurosurgery.

[8]  Kin Seng Chiang,et al.  Simultaneous pressure and temperature measurement with polymer-coated fibre Bragg grating , 2000 .

[9]  A. Nachemson,et al.  Lumbar intradiscal pressure. Experimental studies on post-mortem material. , 1960, Acta orthopaedica Scandinavica. Supplementum.

[10]  J. Cholewicki,et al.  Quantitative discomanometry: technique and reproducibility in vitro. , 1998, Journal of spinal disorders.

[11]  Eric Udd,et al.  Three-axis strain and temperature fiber optic grating sensor , 1996, Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[12]  Eric Udd,et al.  Using multi-axis fiber grating strain sensors to measure transverse strain and transverse strain gradients in composite materials with complex weave structures , 2002, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[13]  L E Claes,et al.  Influence of varying muscle forces on lumbar intradiscal pressure: an in vitro study. , 1996, Journal of biomechanics.

[14]  J. P. Thompson,et al.  Preliminary Evaluation of a Scheme for Grading the Gross Morphology of the Human Intervertebral Disc , 1990, Spine.

[15]  K. Bohnert,et al.  Distributed feedback fiber laser sensor for hydrostatic pressure , 2003, IEEE Photonics Technology Letters.

[16]  P A Cripton,et al.  A minimally disruptive technique for measuring intervertebral disc pressure in vitro: application to the cervical spine. , 2001, Journal of biomechanics.

[17]  A. L. C. Triques,et al.  Simultaneous measurement of temperature and pressure using single fiber Bragg grating and fixed filter demodulation technique , 2004, Iberoamerican Meeting of Optics and the Latin American Meeting of Optics, Lasers and Their Applications.

[18]  Max Aebi,et al.  Lumbar intradiscal pressure measured in the anterior and posterolateral annular regions during asymmetrical loading. , 1998, Clinical biomechanics.

[19]  A. Nachemson The Load on Lumbar Disks in Different Positions of the Body , 1966, Clinical orthopaedics and related research.