Evaluation of agreement between numerical rating scales, visual analogue scoring scales, and force plate gait analysis in dogs.

OBJECTIVE To evaluate the accuracy of numerical rating (NRS) and visual analogue (VAS) scoring scales compared with force plate gait analysis and agreement between observers for each scoring scale. STUDY DESIGN Experimental study. ANIMALS Mixed breed dogs (n=21) with a right limb tibial osteotomy repaired with an external fixator. METHODS Three small-animal veterinarians with orthopedic training scored lameness using NRS and VAS before surgery, and at 4 and 8 weeks after surgery. Peak force and impulse were determined at the same time points using a force plate. Agreement between observers and with force plate data was assessed. Significance was set at P< or =.05. RESULTS Agreement was generally low among observers for both NRS and VAS scores. When evaluated at each time point, an acceptable level of agreement was present only at 4 weeks after surgery. Only impulse had a significant relationship with some of the observers' subjective scores. No significant relationships between any observer's scores and force plate data existed if very lame dogs were omitted. CONCLUSIONS Subjective scoring scales do not replace force plate gait analysis. Agreement is low unless lameness is severe, and each observer uses an individually unique scale. Subjective scoring scales most accurately reflect force plate gait analysis when lameness is severe. CLINICAL RELEVANCE Subjective lameness scoring scales may not accurately reflect lameness and do not replace force plate gait analysis. Observers must stay the same during the duration of a study for accurate analyses.

[1]  M. Saleh,et al.  In defence of gait analysis. Observation and measurement in gait assessment. , 1985, The Journal of bone and joint surgery. British volume.

[2]  G Gettinby,et al.  Comparison of a visual analogue scale and a numerical rating scale for assessment of lameness, using sheep as a model. , 1993, American journal of veterinary research.

[3]  R. Soutas-Little,et al.  Effects of subject velocity on force plate-measured ground reaction forces in healthy greyhounds at the trot. , 1993, American journal of veterinary research.

[4]  C. Decamp Kinetic and kinematic gait analysis and the assessment of lameness in the dog. , 1997, The Veterinary clinics of North America. Small animal practice.

[5]  T C Hearn,et al.  Force plate analysis of triple pelvic osteotomy for the treatment of canine hip dysplasia. , 1991, Veterinary surgery : VS.

[6]  P. Muir,et al.  Clinical efficacy and pharmacokinetics of carprofen in the treatment of dogs with osteoarthritis , 2002, Veterinary Record.

[7]  A. Nolan,et al.  Development of a questionnaire to measure the effects of chronic pain on health-related quality of life in dogs. , 2004, American journal of veterinary research.

[8]  J. Serpell,et al.  Development and validation of a questionnaire for measuring behavior and temperament traits in pet dogs. , 2003, Journal of the American Veterinary Medical Association.

[9]  S. Budsberg,et al.  Contributions to variance in force-plate analysis of gait in dogs. , 1993, American journal of veterinary research.

[10]  Mandi J. Lopez,et al.  Evaluation of gait kinetics in puppies with coxofemoral joint laxity. , 2006, American journal of veterinary research.

[11]  P. Rajala-Schultz,et al.  Association between subjective lameness grade and kinetic gait parameters in horses with experimentally induced forelimb lameness. , 2005, American journal of veterinary research.

[12]  S. Budsberg,et al.  Prospective evaluation of ground reaction forces in dogs undergoing unilateral total hip replacement. , 1996, American journal of veterinary research.

[13]  J. T. Hudson,et al.  Assessing repeatability and validity of a visual analogue scale questionnaire for use in assessing pain and lameness in dogs. , 2004, American journal of veterinary research.

[14]  C. Horstman,et al.  Accuracy and optimization of force platform gait analysis in Labradors with cranial cruciate disease evaluated at a walking gait. , 2005, Veterinary surgery : VS.

[15]  C. Armstrong,et al.  Reliability of ground reaction forces during a vertical jump: implications for functional strength assessment. , 1996, Journal of athletic training.

[16]  N. J. van Klaveren,et al.  Force plate analysis before and after dorsal decompression for treatment of degenerative lumbosacral stenosis in dogs. , 2005, Veterinary surgery : VS.

[17]  M. Markel,et al.  Recombinant human bone morphogenetic protein-2 in absorbable collagen sponge enhances bone healing of tibial osteotomies in dogs. , 2007, Veterinary surgery : VS.

[18]  M. Verstraete,et al.  Force plate analysis of the walking gait in healthy dogs. , 1987, American journal of veterinary research.

[19]  M. Conzemius,et al.  Short-term outcome after total elbow arthroplasty in dogs with severe, naturally occurring osteoarthritis. , 2003, Veterinary surgery : VS.

[20]  Hilary M Clayton,et al.  The force plate: established technology, new applications. , 2005, Veterinary journal.

[21]  M. Tetrick,et al.  Effect of weight reduction on clinical signs of lameness in dogs with hip osteoarthritis. , 2000, Journal of the American Veterinary Medical Association.

[22]  M. Conzemius,et al.  The relationship between limb function and radiographic osteoarthrosis in dogs with stifle osteoarthrosis. , 2003, Veterinary surgery : VS.

[23]  M. Conzemius,et al.  Correlation between subjective and objective measures used to determine severity of postoperative pain in dogs. , 1997, Journal of the American Veterinary Medical Association.

[24]  P. Rumph,et al.  Redistribution of vertical ground reaction force in dogs with experimentally induced chronic hindlimb lameness. , 1995, Veterinary surgery : VS.

[25]  K. A. Johnson,et al.  Force-plate analysis of gait before and after surgical excision of calcified lesions of the supraspinatus tendon in two dogs , 1996, Veterinary Record.