CMR-guided approach to localize and ablate gaps in repeat AF ablation procedure.

OBJECTIVES The aim of this study was to test the feasibility and usefulness of a new delayed-enhancement cardiac magnetic resonance (DE-CMR)-guided approach to ablate gaps in redo procedures. BACKGROUND Recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI) may be related to gaps at the ablation lines. DE-CMR allows identification of radiofrequency lesions and gaps (CMR gaps). METHODS Fifteen patients undergoing repeated AF ablations were included (prior procedure was PVI in all patients and roof-line ablation in 8 patients). Pre-procedure 3-dimensional (3D) DE-CMR was performed with a respiratory-navigated (free-breathing) and electrocardiographically gated inversion-recovery gradient-echo sequence (voxel size 1.25 × 1.25 × 2.5 mm). Endocardium and epicardium were manually segmented to create a 3D reconstruction (DE-CMR model). A pixel signal intensity map was projected on the DE-CMR model and color-coded (thresholds 40 ± 5% and 60 ± 5% of maximum intensity). The DE-CMR model was imported into the navigation system to guide the ablation of CMR gaps, with the operator blinded to electrical data. Fifteen conventional procedures were used as controls to compare procedural duration, radiofrequency, and fluoroscopy times. RESULTS Fifteen patients (56 pulmonary veins [PVs]; 57 ± 8 years of age; 9 with paroxysmal AF) were analyzed. In total, 67 CMR gaps were identified around PVs (mean 4.47 gaps/patient; median length 13.33 mm/gap) and 9 at roof line. All of the electrically reconnected PVs (87.5%) had CMR gaps. The site of electrical PV reconnection (assessed by circular mapping catheter) matched with a CMR gap in 79% of PVs. CMR-guided ablation led to reisolation of 95.6% of reconnected PVs (median radiofrequency time of 13.3 [interquartile range: 7.5 to 21.7] min/patient) and conduction block through the roof line in all patients (1.4 [interquartile range: 0.7 to 3.1] min/patient). Compared with controls, the CMR-guided approach shortened radiofrequency time (1,441 ± 915 s vs. 930 ± 662 s; p = 0.026) but not the procedural duration or fluoroscopy time. CONCLUSIONS DE-CMR can successfully guide repeated PVI procedures by accurately identifying and localizing gaps and may reduce procedural duration and radiofrequency application time.

[1]  Hugh Calkins,et al.  Characterization of radiofrequency ablation lesions with gadolinium-enhanced cardiovascular magnetic resonance imaging. , 2006, Journal of the American College of Cardiology.

[2]  Atul Verma,et al.  Response of Atrial Fibrillation to Pulmonary Vein Antrum Isolation Is Directly Related to Resumption and Delay of Pulmonary Vein Conduction , 2005, Circulation.

[3]  René M. Botnar,et al.  Detection of pulmonary vein and left atrial scar after catheter ablation with three-dimensional navigator-gated delayed enhancement MR imaging: initial experience. , 2007, Radiology.

[4]  J. Brugada,et al.  Integration of 3D Electroanatomic Maps and Magnetic Resonance Scar Characterization Into the Navigation System to Guide Ventricular Tachycardia Ablation , 2011, Circulation. Arrhythmia and electrophysiology.

[5]  Elena Arbelo,et al.  Left Atrial Sphericity: A New Method to Assess Atrial Remodeling. Impact on the Outcome of Atrial Fibrillation Ablation , 2013, Journal of cardiovascular electrophysiology.

[6]  Stefan L. Zimmerman,et al.  Initial experience with magnetic resonance imaging of atrial scar and co-registration with electroanatomic voltage mapping during atrial fibrillation: success and limitations. , 2012, Heart rhythm.

[7]  Matthew Wright,et al.  Catheter ablation for atrial fibrillation: are results maintained at 5 years of follow-up? , 2011, Journal of the American College of Cardiology.

[8]  Andreas Metzner,et al.  Long-Term Results of Catheter Ablation in Paroxysmal Atrial Fibrillation: Lessons From a 5-Year Follow-Up , 2010, Circulation.

[9]  R. Cappato,et al.  Prospective Assessment of Late Conduction Recurrence Across Radiofrequency Lesions Producing Electrical Disconnection at the Pulmonary Vein Ostium in Patients With Atrial Fibrillation , 2003, Circulation.

[10]  S. Ernst,et al.  Recovered Pulmonary Vein Conduction as a Dominant Factor for Recurrent Atrial Tachyarrhythmias After Complete Circular Isolation of the Pulmonary Veins: Lessons From Double Lasso Technique , 2005, Circulation.

[11]  H. Halperin,et al.  Gaps in the Ablation Line as a Potential Cause of Recovery From Electrical Isolation and Their Visualization Using MRI , 2011, Circulation. Arrhythmia and electrophysiology.

[12]  Rob S MacLeod,et al.  Evaluation of Left Atrial Lesions After Initial and Repeat Atrial Fibrillation Ablation: Lessons Learned From Delayed-Enhancement MRI in Repeat Ablation Procedures , 2010, Circulation. Arrhythmia and electrophysiology.

[13]  Alejandro F. Frangi,et al.  GIMIAS: An Open Source Framework for Efficient Development of Research Tools and Clinical Prototypes , 2009, FIMH.

[14]  Mark A. Wood,et al.  Histopathologic characterization of chronic radiofrequency ablation lesions for pulmonary vein isolation. , 2012, Journal of the American College of Cardiology.

[15]  Joshua J. E. Blauer,et al.  New magnetic resonance imaging based method to define extent of left atrial wall injury after the ablation of atrial fibrillation , 2008 .

[16]  Oscar Camara,et al.  Three-Dimensional Architecture of Scar and Conducting Channels Based on High Resolution ce-CMR: Insights for Ventricular Tachycardia Ablation , 2013, Circulation. Arrhythmia and electrophysiology.

[17]  Reza Nezafat,et al.  Recurrence of atrial fibrillation correlates with the extent of post-procedural late gadolinium enhancement: a pilot study. , 2009, JACC. Cardiovascular imaging.

[18]  M. Haissaguerre,et al.  “Dormant” Pulmonary Vein Conduction Revealed by Adenosine after Ostial Radiofrequency Catheter Ablation , 2004, Journal of cardiovascular electrophysiology.

[19]  D. Tamborero,et al.  Circumferential pulmonary vein ablation: does use of a circular mapping catheter improve results? A prospective randomized study. , 2010, Heart rhythm.

[20]  Joshua J. E. Blauer,et al.  Identification and Acute Targeting of Gaps in Atrial Ablation Lesion Sets Using a Real-Time Magnetic Resonance Imaging System , 2012, Circulation. Arrhythmia and electrophysiology.