Design and dynamic simulation of a fixed pitch 56 kW wind turbine drive train with a continuously variable transmission
暂无分享,去创建一个
The dynamic analysis of a horizontal axis fixed pitch wind turbine generator (WTG) rated at 56 kW is discussed. A mechanical Continuously Variable Transmission (CVT) was incorporated in the drive train to provide variable speed operation capability. One goal of the dynamic analysis was to determine if variable speed operation, by means of a mechanical CVT, is capable of capturing the transient power in the WTG/wind environment. Another goal was to determine the extent of power regulation possible with CVT operation.
[1] T. L. Sullivan,et al. Drive train normal modes analysis for the ERDA/NASA 100-kilowatt wind turbine generator , 1977 .
[2] Dean Karnopp,et al. Introduction to physical system dynamics , 1983 .
[3] M. H. Lipner,et al. MOD-0A 200 kW wind turbine generator design and analysis report , 1980 .
[4] R. C. Juvinall. Engineering Considerations of Stress, Strain, and Strength , 1967 .