Automated adjustment of aberration correction in scanning confocal microscopy

This contribution demonstrates an automated adjustment of the coverslip correction collar in scanning confocal microscopy to compensate for aberrations caused by coverslip thickness mismatch. An axial image model is derived for filtering the measured axial image to improve the signal to noise ratio. To find the best collar alignment, 70 axial scans equally spaced over the actuation range are recorded and evaluated automatically. The axial scans reveal that different coverslips have a shift of the maximum intensity for optimal imaging along the collar angle. Correction quality such as the maximum intensity or sharpness of the image are examined and used to find the optimal adjustment. The proposed automated correction is demonstrated with two different coverslips and two biological specimen showing the improved resolution of the obtained confocal microscopy images.

[1]  T. Wilson,et al.  Aberration correction for confocal imaging in refractive‐index‐mismatched media , 1998 .

[2]  J. Mertz Introduction to Optical Microscopy , 2009 .

[3]  Pavel Vesely,et al.  Handbook of Biological Confocal Microscopy, 3rd ed. By James B. Pawley, Editor. Springer Science + Business Media, LLC, New York (2006). ISBN 10: 0‐387‐25921‐X; ISBN 13: 987‐0387‐25921‐5; hardback; 28 + 985 pages , 2007 .

[4]  Cecilia Conde,et al.  Microtubule assembly, organization and dynamics in axons and dendrites , 2009, Nature Reviews Neuroscience.

[5]  Peter Török,et al.  Electromagnetic diffraction of light focused through a planar interface between materials of mismatched refractive indices: an integral representation , 1995 .

[6]  T Wilson,et al.  Refractive-index-mismatch induced aberrations in single-photon and two-photon microscopy and the use of aberration correction. , 2001, Journal of biomedical optics.

[7]  J. C. Dainty,et al.  Wavefront correction of extended objects through image sharpness maximisation , 2005, Other Conferences.

[8]  N. Galjart,et al.  Role of CLASP2 in Microtubule Stabilization and the Regulation of Persistent Motility , 2006, Current Biology.

[9]  Qiang Wu,et al.  Microscope Image Processing , 2010 .

[10]  J. C. Dainty,et al.  Wavefront correction through image sharpness maximisation , 2005, SPIE OPTO-Ireland.

[11]  T Wilson,et al.  Simple optimization procedure for objective lens correction collar setting , 2005, Journal of microscopy.

[12]  S. Hell,et al.  Aberrations in confocal fluorescence microscopy induced by mismatches in refractive index , 1993 .

[13]  J. Pawley,et al.  Handbook of Biological Confocal Microscopy , 1990, Springer US.