Metal-On-Metal Articulation for Artificial Hip Joints: Laboratory Study and Clinical Results

As wear is inevitable with artificial joint replacement, it has to be minimized to avoid possible aseptic loosening following osteolysis due to particle-initiated foreign body reaction. Co-Cr-Mo-C alloys have a long history with only minimum wear when articulating with themselves. This investigation shows that the choice of the alloy has an effect on the wear rate of this articulation couple. Tribological studies in a screening device, a pendulum apparatus and a hip joint simulator showed a marked influence of the environment as well as the diameter of the implants with metal-on-metal articulation. A wear-resistant combination with low friction characteristics has been developed by using a wrought Co-Cr-Mo-C alloy and reducing the implant diameter to 28 mm. Clinical wear rates are comparable with laboratory data and demonstrate the potential of the metal-on-metal articulation to solve the problem of wear-induced osteolysis of hip joint endoprostheses.

[1]  A. Benvenuti,et al.  Metallic debris arising from prosthetic abrasion: investigation of biodegradation of the materials and physiopathology of the bone. , 1983, Italian journal of orthopaedics and traumatology.

[2]  N. Rydell Forces acting on the femoral head-prosthesis. A study on strain gauge supplied prostheses in living persons. , 1966, Acta orthopaedica Scandinavica.

[3]  Walker Ps,et al.  The effects of friction and wear in artificial joints. , 1973 .

[4]  H. Willert,et al.  Comparison of alumina-polyethylene and metal-polyethylene in clinical trials. , 1992, Clinical orthopaedics and related research.

[5]  R. M. Streicher Tribology of Artificial Joints , 1995 .

[6]  G K McKee,et al.  Total hip replacement--past, present and future. , 1982, Biomaterials.

[7]  S. Atamert,et al.  MICROSTRUCTURE, WEAR RESISTANCE, AND STABILITY OF COBALT BASED AND ALTERNATIVE IRON BASED HARDFACING ALLOYS , 1993 .

[8]  M. Semlitsch,et al.  Reactions of the articular capsule to wear products of artificial joint prostheses. , 1977, Journal of biomedical materials research.

[9]  D. Dowson,et al.  Design Considerations for Cushion Form Bearings in Artificial Hip Joints , 1991, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[10]  R. Streicher,et al.  Thin-layer activation of hip-joint prostheses for tribological tests , 1990 .

[11]  P. Walker,et al.  The effects of friction and wear in artificial joints. , 1973, The Orthopedic clinics of North America.

[12]  J. Schurz Biorheologie: Probleme und Ergebnisse in der Medizin , 1983 .

[13]  R. Pilliar Modern metal processing for improved load-bearing surgical implants. , 1991, Biomaterials.