Design and characterization of a photo-acoustic lens to generate tightly-focused and high frequency ultrasound

Ultrasound microscopy uses high frequency (>40 MHz) ultrasound to produce high resolution images. For high resolution microscopy, broadband ultrasound generation and detection is necessary. Because high frequency ultrasound experiences significant absorption loss that results in weaker signals, it is desirable to focus the energy for microscopy applications, which also results in higher lateral resolution. In this work, thermo-elastically generated ultrasound was brought into a tight focus by shining a ns laser pulse onto a thin metal film-coated concave surface. For ultrasound detection, we use polymer microring resonators which have high frequency and wide band response. We experimentally obtained spatial and temporal characteristics of focused ultrasound by optical generation and detection. The 3-dB spot width of the focused ultrasound is ~50 μm. By frequency filtering over 40~100 MHz, 21 μm width is obtained. The temporal profile is close to the time-derivative of laser pulse waveform. Frequency domain analysis for the signal shows that high frequency loss mechanism of our system is dominated by angular directivity of the microring detector. The issues to improve high frequency response are discussed.

[1]  Michael C. Kolios,et al.  Ultrasonic biomicroscopy of viable, dead and apoptotic cells. , 1997, Ultrasound in medicine & biology.

[2]  Aaron Fenster,et al.  Three-dimensional high-frequency ultrasound imaging for longitudinal evaluation of liver metastases in preclinical models. , 2005, Cancer research.

[3]  Sheng-Wen Huang,et al.  Low-noise wideband ultrasound detection using polymer microring resonators. , 2008, Applied physics letters.

[4]  A. Joyner,et al.  Ultrasound backscatter microscope analysis of early mouse embryonic brain development. , 1995, Proceedings of the National Academy of Sciences of the United States of America.

[5]  Zhilie Tang,et al.  Photoacoustic tomography imaging based on a 4f acoustic lens imaging system. , 2007, Optics express.

[6]  D. A. Christopher,et al.  40-MHZ echocardiography scanner for cardiovascular assessment of mouse embryos. , 1998, Ultrasound in medicine & biology.

[7]  Adam D. Maxwell,et al.  Polymer microring resonators and their sensor applications , 2008, SPIE OPTO.

[8]  Lihong V. Wang,et al.  High-numerical-aperture-based virtual point detectors for photoacoustic tomography. , 2008, Applied physics letters.

[9]  J W Hunt,et al.  © 1999 Cancer Research Campaign Article no. bjoc.1999.0724 Ultrasound imaging of apoptosis: high-resolution noninvasive , 2022 .

[10]  D. Blackstock Fundamentals of Physical Acoustics , 2000 .

[11]  David E Goertz,et al.  High-frequency Doppler ultrasound monitors the effects of antivascular therapy on tumor blood flow. , 2002, Cancer research.

[12]  Martin Frenz,et al.  Real-time three-dimensional optoacoustic imaging using an acoustic lens system , 2004 .

[13]  Chung-Yen Chao,et al.  Polymer microring resonators fabricated by nanoimprint technique , 2002 .

[14]  F. Foster,et al.  Use of a high frequency ultrasound microscope to image the action of 2-nitroimidazoles in multicellular spheroids. , 1992, British Journal of Cancer.

[15]  Minghua Xu,et al.  Time-domain reconstruction for thermoacoustic tomography in a spherical geometry , 2002, IEEE Transactions on Medical Imaging.