Dosimetric evaluation of GAFCHROMIC® XR type T and XR type R films

The high spatial resolution of radiochromic film makes it ideal for dosimetric measurements and dose distributions in regions of high dose gradient. Intensity‐modulated radiation therapy, intravascular brachytherapy, and eye‐plaque radiation therapy demand precise spatial dosimetric calculations. Such precision is not possible with conventional dosimeters, such as thermoluminescent dosimeters and ionization chambers. Recently, new GAFCHROMIC® XR type T and type R films have been developed for radiation dosimetry, specifically in interventional radiology procedures. Dosimetric characteristics (i.e., linearity, post‐exposure density growth, energy dependence, dose‐rate dependence, and UV light sensitivity) of these new films were investigated. To evaluate the clinical applications of these films, their characteristics were compared with other commercially available film models. GAFCHROMIC® XR type T and type R films were found to be more sensitive to low‐energy doses as compared with GAFCHROMIC® MD‐55 films. PACS numbers: 87.66‐a, 87.53‐j

[1]  D. F. Lewis,et al.  A thin film recording medium for use in food irradiation , 1988 .

[2]  B. Bjärngard,et al.  Doses on the central axes of narrow 6-MV x-ray beams. , 1990, Medical physics.

[3]  D. F. Lewis,et al.  Sensitometry of the response of a new radiochromic film dosimeter to gamma radiation and electron beams , 1991 .

[4]  R. Nath,et al.  Photon energy dependence of the sensitivity of radiochromic film and comparison with silver halide film and LiF TLDs used for brachytherapy dosimetry. , 1991, Medical physics.

[5]  W. Mclaughlin,et al.  Metal-polysiloxane shields for radiation therapy of maxillo-facial tumors. , 1991, Medical physics.

[6]  J. Sayeg,et al.  A new method for characterizing beta-ray ophthalmic applicator sources. , 1991, Medical physics.

[7]  A R Smith,et al.  Characterization of a multi-leaf collimator system. , 1993, International journal of radiation oncology, biology, physics.

[8]  James M. Galvin,et al.  CHARACTERIZATION OF A MULTILEAF COLLIMATOR SYSTEM , 1993 .

[9]  K. Mehta,et al.  The effects of humidity on the response of radiochromic film dosimeters FWT-60-00 and gafchromic-DM-1260 , 1994 .

[10]  S. Chiu‐Tsao,et al.  High-sensitivity GafChromic film dosimetry for 125I seed. , 1994, Medical physics.

[11]  E. McCullough,et al.  The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics. , 1994, Medical physics.

[12]  Arne Miller,et al.  Novel Radiochromic Films for Clinical Dosimetry , 1996 .

[13]  A. Niroomand-rad,et al.  Radiation dose pertubation at tissue-titanium dental interfaces in head and neck cancer patients , 1996 .

[14]  A. Niroomand-rad,et al.  Radiation dose perturbation at tissue-titanium dental interfaces in head and neck cancer patients. , 1996, International journal of radiation oncology, biology, physics.

[15]  G S Ibbott,et al.  Dosimetric characteristics of an improved radiochromic film. , 1996, Medical physics.

[16]  J Cygler,et al.  GafChromic MD-55: investigated as a precision dosimeter. , 1997, Medical physics.

[17]  J F Williamson,et al.  Quantitative evaluation of radiochromic film response for two-dimensional dosimetry. , 1997, Medical physics.

[18]  H. Amols,et al.  Predicting optical densitometer response as a function of light source characteristics for radiochromic film dosimetry. , 1997, Medical physics.

[19]  S. Vatnitsky,et al.  Radiochromic film dosimetry for verification of dose distributions delivered with proton-beam radiosurgery. , 1997, Physics in medicine and biology.

[20]  Effects of read-out light sources and ambient light on radiochromic film. , 1998, Physics in medicine and biology.

[21]  D. Duggan,et al.  Dose distribution for a 32P-impregnated coronary stent: comparison of theoretical calculations and measurements with radiochromic film. , 1998, International journal of radiation oncology, biology, physics.

[22]  J. Galvin,et al.  Radiochromic film dosimetry: recommendations of AAPM Radiation Therapy Committee Task Group 55. American Association of Physicists in Medicine. , 1998, Medical physics.

[23]  Radiochromic film dosimetry of a high dose rate beta source for intravascular brachytherapy. , 1999, Medical physics.

[24]  C. Fiorino,et al.  Dosimetry of Gamma Knife and linac-based radiosurgery using radiochromic and diode detectors. , 1999, Physics in medicine and biology.

[25]  D L McShan,et al.  Calibration and quality assurance for rounded leaf-end MLC systems. , 2001, Medical physics.

[26]  P. Metcalfe,et al.  High sensitivity radiochromic film dose comparisons. , 2002, Physics in medicine and biology.

[27]  Corresponding dose response of radiographic film with layered gafchromic film. , 2002, Physics in medicine and biology.

[28]  P. Murphy,et al.  MEASURING SKIN DOSE WITH RADIOCHROMIC DOSIMETRY FILM IN THE CARDIAC CATHETERIZATION LABORATORY , 2002, Health physics.

[29]  S. Morrill,et al.  MLC quality assurance techniques for IMRT applications. , 2003, Medical physics.

[30]  R. Y. Chu,et al.  A study of GafChromic XR Type R film response with reflective‐type densitometers and economical flatbed scanners , 2003, Journal of applied clinical medical physics.

[31]  S. Scheib,et al.  High precision film dosimetry with GAFCHROMIC films for quality assurance especially when using small fields. , 2003, Medical physics.

[32]  M. Butson,et al.  Polarization effects on a high-sensitivity radiochromic film. , 2003, Physics in medicine and biology.

[33]  S M Morrill,et al.  MLC dosimetric characteristics for small field and IMRT applications. , 2003, Medical physics.

[34]  J F Williamson,et al.  Dependence of radiochromic film optical density post-exposure kinetics on dose and dose fractionation. , 2003, Medical physics.

[35]  A. Mack,et al.  A System for Quality Assurance in Radiosurgery , 2004 .

[36]  S. Chiu‐Tsao,et al.  Dose response characteristics of new models of GAFCHROMIC films: dependence on densitometer light source and radiation energy. , 2004, Medical physics.