N-terminal sequence tagging using reliably determined b2 ions: a useful approach to deconvolute tandem mass spectra of co-fragmented peptides in proteomics.

With the recent introduction of higher-energy collisional dissociation (HCD) in Orbitrap mass spectrometry, the popularity of that technique has grown tremendously in the proteomics society. HCD spectra, however, are characterized by a limited distribution of bn-type ions, which permit the generation of reliable sequence tags based on complementary b,y pairs both for de novo sequencing and sequence tagging strategies. Instead, most peptide HCD spectra (~95%) are dominated with b2 ions. In this work, we analyzed positive predictive values of b2 ions in HCD, and found that b2 ions can be determined with >97% certainty in the presence of a2 and its complementary yn-2 ions. Analytically, b2 ions provide information on the composition of the first two N-terminal amino acids in peptides. Their utilization in N-terminal sequence tagging leads to a significant decrease in false discovery rate by filtering out false positives while retaining true positive identifications. As a consequence, the number of peptide spectrum matches (PSMs) increased by 4.8% at fixed FDR (1%). This approach allows for deconvolution of mixture spectra and increased the number of PSM to 9.2% in a complex human sample and to 24% in a complex sample of synthetic peptides at 1% FDR.

[1]  P. Pevzner,et al.  De novo peptide sequencing and identification with precision mass spectrometry. , 2007, Journal of proteome research.

[2]  Mikhail M Savitski,et al.  Improving Protein Identification Using Complementary Fragmentation Techniques in Fourier Transform Mass Spectrometry* , 2005, Molecular & Cellular Proteomics.

[3]  M. Mann,et al.  A large synthetic peptide and phosphopeptide reference library for mass spectrometry–based proteomics , 2013, Nature Biotechnology.

[4]  Sándor Suhai,et al.  Fragmentation Pathways of Protonated Peptides , 2006 .

[5]  Mikhail M Savitski,et al.  New Data Base-independent, Sequence Tag-based Scoring of Peptide MS/MS Data Validates Mowse Scores, Recovers Below Threshold Data, Singles Out Modified Peptides, and Assesses the Quality of MS/MS Techniques* , 2005, Molecular & Cellular Proteomics.

[6]  Felipe Maia Galvão França,et al.  Effectively addressing complex proteomic search spaces with peptide spectrum matching , 2013, Bioinform..

[7]  John R Yates,et al.  Can the false‐discovery rate be misleading? , 2011, Proteomics.

[8]  Frank Kjeldsen,et al.  Deconvolution of mixture spectra and increased throughput of peptide identification by utilization of intensified complementary ions formed in tandem mass spectrometry. , 2013, Journal of proteome research.

[9]  M. Savitski,et al.  Proteomics-grade de novo sequencing approach. , 2005, Journal of proteome research.

[10]  Yasset Perez-Riverol,et al.  Evaluation of phenylthiocarbamoyl-derivatized peptides by electrospray ionization mass spectrometry: selective isolation and analysis of modified multiply charged peptides for liquid chromatography-tandem mass spectrometry experiments. , 2010, Analytical chemistry.

[11]  M. Wilm,et al.  Error-tolerant identification of peptides in sequence databases by peptide sequence tags. , 1994, Analytical chemistry.

[12]  D. N. Perkins,et al.  Probability‐based protein identification by searching sequence databases using mass spectrometry data , 1999, Electrophoresis.

[13]  Jürgen Cox,et al.  A systematic investigation into the nature of tryptic HCD spectra. , 2012, Journal of proteome research.

[14]  J. Yates,et al.  An approach to correlate tandem mass spectral data of peptides with amino acid sequences in a protein database , 1994, Journal of the American Society for Mass Spectrometry.

[15]  Robert J Chalkley,et al.  When target-decoy false discovery rate estimations are inaccurate and how to spot instances. , 2013, Journal of proteome research.

[16]  Bin Ma,et al.  PEAKS DB: De Novo Sequencing Assisted Database Search for Sensitive and Accurate Peptide Identification* , 2011, Molecular & Cellular Proteomics.

[17]  F. McLafferty,et al.  Automated de novo sequencing of proteins by tandem high-resolution mass spectrometry. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[18]  Brett G Larsen,et al.  Peptide end sequencing by orthogonal MALDI tandem mass spectrometry. , 2002, Journal of proteome research.

[19]  David L Tabb,et al.  DirecTag: accurate sequence tags from peptide MS/MS through statistical scoring. , 2008, Journal of proteome research.

[20]  P. Pevzner,et al.  InsPecT: identification of posttranslationally modified peptides from tandem mass spectra. , 2005, Analytical chemistry.

[21]  Juan Antonio Vizcaíno,et al.  HI-bone: a scoring system for identifying phenylisothiocyanate-derivatized peptides based on precursor mass and high intensity fragment ions. , 2013, Analytical chemistry.

[22]  X. Yao,et al.  Site-preferential dissociation of peptides with active chemical modification for improving fragment ion detection. , 2010, Analytical chemistry.

[23]  J. A. Taylor,et al.  Implementation and uses of automated de novo peptide sequencing by tandem mass spectrometry. , 2001, Analytical chemistry.

[24]  G Padron,et al.  Automated interpretation of low‐energy collision‐induced dissociation spectra by SeqMS, a software aid for de novo sequencing by tandem mass spectrometry , 2000, Electrophoresis.

[25]  W. Lehmann,et al.  Patchwork peptide sequencing: Extraction of sequence information from accurate mass data of peptide tandem mass spectra recorded at high resolution* , 2002, Proteomics.

[26]  P. Pevzner,et al.  Target-Decoy Approach and False Discovery Rate: When Things May Go Wrong , 2011, Journal of the American Society for Mass Spectrometry.

[27]  R. Zubarev,et al.  Are the majority of a(2)-ions cyclic? , 2010, Physical chemistry chemical physics : PCCP.

[28]  J. Yates,et al.  GutenTag: high-throughput sequence tagging via an empirically derived fragmentation model. , 2003, Analytical chemistry.

[29]  Simon J. Gaskell,et al.  Promotion and Stabilization of b1 ions in Peptide Phenythiocarbamoyl Derivatives: Analogies with Condensed-phase Chemistry , 1997 .

[30]  Hyungwon Choi,et al.  False discovery rates and related statistical concepts in mass spectrometry-based proteomics. , 2008, Journal of proteome research.

[31]  R. Wohlhueter,et al.  N-terminal derivatization of peptides with isothiocyanate analogues promoting Edman-type cleavage and enhancing sensitivity in electrospray ionization tandem mass spectrometry analysis. , 2009, Analytical chemistry.

[32]  A. G. Harrison To b or not to b: the ongoing saga of peptide b ions. , 2009, Mass spectrometry reviews.