Is the coefficient of variation a valid measure for detecting sincerity of effort of grip strength?

The wide use of the coefficient of variation in detecting sincerity of effort is puzzling since existing research findings regarding its effectiveness are contradictory. The lack of empirical support in the literature raises the question of whether or not the coefficient of variation is a valid measure for detecting sincerity of effort. Many clinicians, especially those who use a computer software to calculate the coefficient of variation, may not understand how the coefficient of variation is derived and what it is based on. The coefficient of variation is a measure of relative variability and would be used correctly only if the average and the standard deviation of grip strength trials increased proportionally. This case study, however, demonstrated that the average and standard deviation of grip strength are independent. Thus, the coefficient of variation is not a valid measure of sincerity of effort. In addition, this study indicated that the coefficient of variation may be inflated in individuals after carpal tunnel release surgery. The author, therefore, cautions clinicians against the use of the coefficient of variation as a measure of sincerity of effort especially in injured individuals with compromised hand strength.

[1]  B. Niebuhr,et al.  Voluntary Control of Submaximal Grip Strength , 1990, American journal of physical medicine & rehabilitation.

[2]  R. Stein,et al.  Changes in firing rate of human motor units during linearly changing voluntary contractions , 1973, The Journal of physiology.

[3]  J. Bennett,et al.  Carpal arch alteration after carpal tunnel release. , 1986, The Journal of hand surgery.

[4]  F. Biering-Sørensen Physical measurements as risk indicators for low-back trouble over a one-year period. , 1984, Spine.

[5]  G. Lister,et al.  Detection of submaximal effort by use of the rapid exchange grip. , 1989, The Journal of hand surgery.

[6]  J. Baker,et al.  Burden of proof in detection of submaximal effort. , 1998, Work.

[7]  V. Mathiowetz,et al.  Grip and pinch strength: normative data for adults. , 1985, Archives of physical medicine and rehabilitation.

[8]  T Hansson,et al.  Isometric Strength Testing: Recommendations Based on a Statistical Analysis of the Procedure , 1986, Spine.

[9]  G. Lister,et al.  Measurement of grip strength in the diagnosis of wrist pain. , 1988, The Journal of hand surgery.

[10]  A L Dellon,et al.  Detection of submaximal effort with computer-assisted grip strength measurements. , 1997, Journal of occupational and environmental medicine.

[11]  H M Stokes,et al.  The seriously uninjured hand--weakness of grip. , 1983, Journal of occupational medicine. : official publication of the Industrial Medical Association.

[12]  R. de Marco,et al.  Long-term instability of fasting plasma glucose, a novel predictor of cardiovascular mortality in elderly patients with non-insulin-dependent diabetes mellitus: the Verona Diabetes Study. , 1997, Circulation.

[13]  P. Harber,et al.  Static ergonomic strength testing in evaluating occupational back pain. , 1984, Journal of occupational medicine. : official publication of the Industrial Medical Association.

[14]  R W Bohannon,et al.  DIFFERENTIATION OF MAXIMAL FROM SUBMAXIMAL STATIC ELBOW FLEXOR EFFORTS BY MEASUREMENT VARIABILITY , 1987, American journal of physical medicine.

[15]  H. M. Stokes,et al.  Identification of low-effort patients through dynamometry. , 1995, The Journal of hand surgery.

[16]  Denis Brunt,et al.  Assessment in occupational therapy and physical therapy , 1997 .

[17]  J C Simonsen Coefficient of variation as a measure of subject effort. , 1995, Archives of physical medicine and rehabilitation.

[18]  Simple method to determine sincerity of effort during a maximal isometric test of grip strength. , 1983 .

[19]  D H Janda,et al.  Objective evaluation of grip strength. , 1987, Journal of occupational medicine. : official publication of the Industrial Medical Association.

[20]  P M King Analysis of approaches to detection of sincerity of effort through grip strength measurement. , 1998, Work.

[21]  M E Robinson,et al.  Reproducibility of maximal versus submaximal efforts in an isometric lumbar extension task. , 1991, Journal of spinal disorders.

[22]  E. Fess,et al.  The need for reliability and validity in hand assessment instruments. , 1986, The Journal of hand surgery.

[23]  Richard C. Nelson,et al.  Assessing Sincerity of Effort in Maximal Grip Strength Tests , 1989, American journal of physical medicine & rehabilitation.

[24]  B. Niebuhr,et al.  Detecting sincerity of effort when measuring grip strength. , 1987, American journal of physical medicine.

[25]  V. Edgerton,et al.  Mammalian Muscle Fiber Types and Their Adaptability , 1978 .

[26]  R. Ashford,et al.  Sensitivity of the Jamar Dynamometer in detecting submaximal grip effort. , 1996, The Journal of hand surgery.

[27]  M. Robinson,et al.  Detection of submaximal effort in isometric and isokinetic knee extension tests. , 1996, The Journal of orthopaedic and sports physical therapy.

[28]  C. Esler,et al.  Grip Strength following Carpal Tunnel Decompression , 1993, Journal of hand surgery.

[29]  K. Schultz-Johnson Assessment of upper extremity-injured persons' return to work potential. , 1987, The Journal of hand surgery.

[30]  H. C. Hoeck,et al.  Reproducibility of Growth Hormone and Cortisol Responses to the Insulin Tolerance Test and the Short ACTH Test in Normal Adults , 1997, Hormone and metabolic research = Hormon- und Stoffwechselforschung = Hormones et metabolisme.

[31]  M J Botte,et al.  Analysis of pinch and grip strength after carpal tunnel release. , 1989, The Journal of hand surgery.

[32]  D. Lechner,et al.  Detecting sincerity of effort: a summary of methods and approaches. , 1998, Physical therapy.

[33]  R B Stein,et al.  The orderly recruitment of human motor units during voluntary isometric contractions , 1973, The Journal of physiology.

[34]  G. Lister The Hand: Diagnosis and Indications , 1984 .

[35]  S. Mackinnon,et al.  An evaluation of rapid exchange and simultaneous grip tests. , 1993, The Journal of hand surgery.