Optical efficiency study of PV Crossed Compound Parabolic Concentrator

Static solar concentrators present a solution to the challenge of reducing the cost of Building Integrated Photovoltaic (BIPV) by reducing the area of solar cells. In this study a 3-D ray trace code has been developed using MATLAB in order to determine the theoretical optical efficiency and the optical flux distribution at the photovoltaic cell of a 3-D Crossed Compound Parabolic Concentrator (CCPC) for different incidence angles of light rays. It was found that the CCPC with a concentration ratio of 3.6× represents an improved geometry compared to a 3-D Compound Parabolic Concentrator (CPC) for the use as a static solar concentrator. The CCPC has a maximum optical efficiency of 95%, in line with the optical efficiency of the 3-D CPC, with the added advantage of having a square entry and exit aperture. A series of preliminary experimental measurements were taken on a setup of nine solar cells. The experimental results provide validation of the MATLAB code developed, showing a deviation of 12±2% from the simulation results, thus confirming that the code can be used to investigate different concentration ratios of the CCPC.

[1]  Reinhard Radermacher,et al.  A high efficiency solar air conditioner using concentrating photovoltaic/thermal collectors , 2012 .

[2]  Francesco Roca,et al.  Influence of metal grid patterns on the performance of silicon solar cells at different illumination levels , 2009 .

[3]  Shafiqur Rehman,et al.  Experimental and numerical study on non-concentrating and symmetric unglazed compound parabolic photovoltaic concentration systems , 2014 .

[4]  John Richard Mattox,et al.  Ray tracing simulations for a modified compound parabolic concentrator to be considered for the VERITAS project , 1999 .

[5]  Nabin Sarmah,et al.  Evaluation and optimization of the optical performance of low-concentrating dielectric compound parabolic concentrator using ray-tracing methods. , 2011, Applied optics.

[6]  Evan Franklin,et al.  Effects of highly non-uniform illumination distribution on electrical performance of solar cells , 2002 .

[7]  A. Rabl Optical and thermal properties of Compound Parabolic Concentrators , 1975 .

[8]  Hulin Huang,et al.  A Novel Lens-Walled Compound Parabolic Concentrator for Photovoltaic Applications , 2012 .

[9]  M. Oron,et al.  Losses in a three-dimensional compound parabolic concentrator as a second stage of a solar concentrator , 1993 .

[10]  Qiang Yao,et al.  The Effect of Non-Uniform Illumination on the Performance of Conventional Polycrystalline Silicon Solar Cell , 2008 .

[11]  R. W. Bentley,et al.  The development and testing of small concentrating PV systems , 1999 .

[12]  W. T. Welford,et al.  The Optics of Nonimaging Concentrators: Light and Solar Energy , 1978 .

[13]  A. Goetzberger,et al.  Two-stage concentrator permitting concentration factors up to 300x with one-axis tracking , 1996 .

[14]  Tapas K. Mallick,et al.  Performance analysis of a reflective 3D crossed compound parabolic concentrating photovoltaic system for building façade integration , 2012 .

[15]  V. A. Grilikhes,et al.  Effect of nonuniform light intensity distribution on temperature coefficients of concentrator solar cells , 2003, 3rd World Conference onPhotovoltaic Energy Conversion, 2003. Proceedings of.

[16]  Ji Jie,et al.  Design and investigation of a novel lens-walled compound parabolic concentrator with air gap , 2014 .

[17]  Tapas K. Mallick,et al.  The design and experimental characterisation of an asymmetric compound parabolic photovoltaic concentrator for building façade integration in the UK , 2004 .

[18]  Roland Winston,et al.  High Collection Nonimaging Optics , 1989, Other Conferences.

[19]  Marc A. Rosen,et al.  A critical review of photovoltaic–thermal solar collectors for air heating , 2011 .