Subpicosecond laser ablation of dental enamel

Laser ablation of dental enamel with subpicosecond laser pulses has been studied over the intensity range of (0.1–1.4)×1014 W/cm2 using 95 and 150 fs pulses at a pulse repetition rate of 1 kHz. The experimentally determined ablation threshold of 2.2±0.1 J/cm2 was in good agreement with theoretical predictions based on an electrostatic ablation model. The ablation rate increased linearly with the laser fluence for up to 15 times the ablation threshold. The absence of collateral damage was observed using optical and scanning electron microscopy. Pulpal temperature measurements showed an increase of about 10 °C during the 200 s course of ablation. However, air cooling at a rate of 5 l/min resulted in the intrapulpal temperature being maintained below the pulpal damage threshhold of 5.5 °C. The material removal rates for subpicosecond precision laser ablation of dental enamel are compared with other techniques.

[1]  Gerard Mourou,et al.  Laser‐induced breakdown by impact ionization in SiO2 with pulse widths from 7 ns to 150 fs , 1994 .

[2]  B. Luther-Davies,et al.  Ablation of solids by femtosecond lasers: ablation mechanism and ablation thresholds for metals and dielectrics , 2002 .

[3]  B. Luther-Davies,et al.  Matter in ultrastrong laser fields , 1992 .

[4]  Boris N. Chichkov,et al.  Precise laser ablation with ultrashort pulses , 1997 .

[5]  F. Krausz,et al.  Incubation of laser ablation in fused silica with 5-fs pulses , 1999 .

[6]  L. Reinisch,et al.  Laser ablation as a function of the primary absorber in dentin , 1997, Lasers in surgery and medicine.

[7]  Y. V. Afanasiev,et al.  Hydrodynamic regime of laser ablation of metals by ultrashort pulses of low fluence , 1999 .

[8]  Beop-Min Kim,et al.  Optical feedback signal for ultrashort laser pulse ablation of tissue 1 Work performed at Lawrence L , 1997 .

[9]  L ZACH,et al.  PULP RESPONSE TO EXTERNALLY APPLIED HEAT. , 1965, Oral surgery, oral medicine, and oral pathology.

[10]  D. Bäuerle Laser Processing and Chemistry , 1996 .

[11]  Josef F. Bille,et al.  Laser-induced optical breakdown on hard and soft tissues and its dependence on the pulse duration: experiment and model , 1996 .

[12]  Barry Luther-Davies,et al.  Ultrafast Ablation with High-Pulse-Rate Lasers. Part II: Experiments on Laser Deposition of Amorphous Carbon Films , 1999 .

[13]  Barry Luther-Davies,et al.  Ultrafast ablation with high-pulse-rate lasers. Part I: Theoretical considerations , 1999 .

[14]  Brent C. Stuart,et al.  Ultrashort-pulse laser machining of dielectric materials , 1999 .

[15]  M. Niemz,et al.  Cavity Preparation with the Nd:YLF Picosecond Laser , 1995, Journal of dental research.

[16]  Ward Small,et al.  Plasma mediated ablation of biological tissues with nanosecond-to-femtosecond laser pulses: relative role of linear and nonlinear absorption , 1996 .

[17]  Michael D. Perry,et al.  Ultrashort pulse lasers for hard tissue ablation , 1996 .

[18]  G. Altshuler,et al.  A laser‐abrasive method for the cutting of enamel and dentin , 2001, Lasers in surgery and medicine.