A Galvanic Sensor for Monitoring the Corrosion Condition of the Concrete Reinforcing Steel: Relationship Between the Galvanic and the Corrosion Currents

This work reports a study carried out on the design and performance of galvanic and polarization resistance sensors to be embedded in concrete systems for permanent monitoring of the corrosion condition of reinforcing steel, aiming to establish a correlation between the galvanic currents, Igal, and the corrosion currents, Icorr, estimated from the polarization resistance, Rp. Sensors have been tested in saturated Ca(OH)2 aqueous solutions, under a variety of conditions, simulating the most important parameters that can accelerate the corrosion of concrete reinforcing steel, such as carbonation, ingress of chloride ions, presence or absence of O2. For all the conditions, the influence of temperature (20 to 55 °C) has also been considered. From this study, it could be concluded that the galvanic currents are sensitive to the various parameters following a trend similar to that of the Rp values. A relationship between the galvanic and the corrosion current densities was obtained and the limiting values of the Igal, indicative of the state condition of the reinforcing steel for the designed sensor, were established.

[1]  W. John McCarter,et al.  Sensor systems for use in reinforced concrete structures , 2004 .

[2]  Palle Thoft-Christensen Stochastic Modelling of the Crack Initiation Time for Reinforced Concrete Structures , 2000 .

[3]  Carmen Andrade,et al.  Examples of reinforcement corrosion monitoring by embedded sensors in concrete structures , 2009 .

[4]  C. Page,et al.  Corrosion of reinforcement in concrete , 1990 .

[5]  Carmen Andrade,et al.  Corrosion rate monitoring in the laboratory and on-site , 1996 .

[6]  V. Saraswathy,et al.  Corrosion Monitoring of Reinforced Concrete Structures – A Review , 2007, International Journal of Electrochemical Science.

[8]  Michael Raupach,et al.  Models for the propagation phase of reinforcement corrosion – an overview , 2006 .

[9]  Michael Raupach,et al.  Corrosion monitoring sensors for durability assessment of concrete structures , 2000, Smart Structures.

[10]  Adam Neville CORROSION OF REINFORCEMENT , 1983 .

[11]  Kevin Davies,et al.  The use of permanent corrosion monitoring in new and existing reinforced concrete structures , 2002 .

[12]  Manuela M. Salta,et al.  Sensor for oxygen evaluation in concrete , 2006 .

[13]  Lan Chung,et al.  Development of a galvanic sensor system for detecting the corrosion damage of the steel embedded in concrete structure: Part 2. Laboratory electrochemical testing of sensors in concrete , 2005 .

[14]  Maria de Fátima Montemor,et al.  Multiprobe chloride sensor for in situ monitoring of reinforced concrete structures , 2006 .

[15]  Lan Chung,et al.  DEVELOPMENT OF A GALVANIC SENSOR SYSTEM FOR DETECTING THE CORROSION DAMAGE OF THE STEEL EMBEDDED IN CONCRETE STRUCTURES: PART 1. LABORATORY TESTS TO CORRELATE GALVANIC CURRENT WITH ACTUAL DAMAGE , 2003 .

[16]  R. B. Figueira,et al.  Long-Term Efficiency of Two Organic Corrosion Inhibitors for Reinforced Concrete , 2010 .

[17]  Ying Lei,et al.  Monitoring corrosion of reinforcement in concrete structures via fiber Bragg grating sensors , 2009 .

[18]  K. Darowicki,et al.  Evaluation of reinforcement corrosion rate in concrete structures by electrochemical noise measurements , 2006 .

[19]  Sharon L. Wood,et al.  Wireless low-cost corrosion sensors for reinforced concrete structures , 2005, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[20]  M. Raupach CHLORIDE-INDUCED MACROCELL CORROSION OF STEEL IN CONCRETE - THEORETICAL BACKGROUND AND PRACTICAL CONSEQUENCES , 1996 .

[21]  H. S. Wolff,et al.  iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.

[22]  Miguel Ángel Climent-Llorca,et al.  Embeddable Ag/AgCl sensors for in-situ monitoring chloride contents in concrete , 1996 .

[23]  M. Ohtsu,et al.  Estimation of Corrosion in Reinforced Concrete by Electrochemical Techniques and Acoustic Emission , 2005 .

[24]  Michael Raupach,et al.  Monitoring system for the corrosion risk of steel in concrete structures , 1992 .