A Study on The Evaluation Criteria of Carbon Emission and the Development of the Evaluation Method in Apartment House

This study creates the evaluation criteria to analyze the emission quantity in the complex of apartment house among domestic buildings and proposes how to calculate the emission quantity by the only simple information of apartment house. The study shows that in order to create the index of carbon emission evaluation criteria, emission quantity for its input materials in these 27 apartment houses are 445,412g- for apartment building, 474,322g- for the basement parking lot, 483,523g- for welfare facility, 729,957g- for sales facility, 743,560g- for other facility, 26,782g- for public facility, 43,659g- for landscape, 1,113g- for indoor facility, 11,251g- for outdoor facility and 891g- for common temporary based on the average emission by facility. We can also see the analysis data that in case of using the selected factors only, the rate of error is 7.51% comparing with the emission quantity by using simplified LCA method this study suggests for the whole range of apartment houses and the rate of error is average 3.24% using selective and main materials. And this it is evaluated that we can get the result which is similar to the actual emission quantity with only the simple information about the apartment house.