MARS spectral molecular imaging of lamb tissue: data collection and image analysis

Spectral molecular imaging is a new imaging technique able to discriminate and quantify different components of tissue simultaneously at high spatial and high energy resolution. Our MARS scanner is an x-ray based small animal CT system designed to be used in the diagnostic energy range (20–140 keV). In this paper, we demonstrate the use of the MARS scanner, equipped with the Medipix3RX spectroscopic photon-processing detector, to discriminate fat, calcium, and water in tissue. We present data collected from a sample of lamb meat including bone as an illustrative example of human tissue imaging. The data is analyzed using our 3D Algebraic Reconstruction Algorithm (MARS-ART) and by material decomposition based on a constrained linear least squares algorithm. The results presented here clearly show the quantification of lipid-like, water-like and bone-like components of tissue. However, it is also clear to us that better algorithms could extract more information of clinical interest from our data. Because we are one of the first to present data from multi-energy photon-processing small animal CT systems, we make the raw, partial and fully processed data available with the intention that others can analyze it using their familiar routines. The raw, partially processed and fully processed data of lamb tissue along with the phantom calibration data can be found at http://hdl.handle.net/10092/8531.

[1]  Rafidah Zainon,et al.  Construction and Operation of the MARS-CT Scanner , 2009 .

[2]  B. Archer,et al.  The AAPM/RSNA physics tutorial for residents. Typical patient radiation doses in diagnostic radiology. , 1999, Radiographics : a review publication of the Radiological Society of North America, Inc.

[3]  Nicola Tartoni,et al.  Study of charge-sharing in MEDIPIX3 using a micro-focused synchrotron beam , 2011 .

[4]  K. Smith,et al.  Semiconductor pixel detectors , 2000 .

[5]  S. Nik,et al.  Optimal material discrimination using spectral x-ray imaging. , 2011, Physics in medicine and biology.

[6]  G. Pellegrini,et al.  Charge sharing measurements of pixilated CdTe using Medipix-II chip , 2004, Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510).

[7]  David P. Cormode,et al.  Letter to the Editor re: Spectral Hounsfield units—a new radiological concept , 2013, European Radiology.

[8]  Philip H Butler,et al.  Processing of spectral X-ray data with principal components analysis , 2011 .

[9]  Marco Endrizzi,et al.  Multi-energy computed tomography using pre-reconstruction decomposition and iterative reconstruction algorithms , 2012 .

[10]  Gerhard Martens,et al.  Preclinical spectral computed tomography of gold nano-particles , 2011 .

[11]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[12]  R Aamir,et al.  Characterization of Si and CdTe sensor layers in Medipix assemblies using a microfocus x-ray source , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[13]  Rafidah Zainon,et al.  Spectral Micro-CT Imaging of Ex Vivo Atherosclerotic Plaque , 2012 .

[14]  A. Butler,et al.  First CT using Medipix3 and the MARS-CT-3 spectral scanner , 2011 .

[15]  A. Butler,et al.  Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE , 2010, European Radiology.

[16]  G. Anton,et al.  Quantitative Material Reconstruction in CT with Spectroscopic X-ray Pixel Detectors -- a Simulation Study , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[17]  Robert Doesburg,et al.  Characterization of Medipix3 with the MARS readout and software , 2011 .

[18]  J. Jakubek,et al.  Semiconductor Pixel detectors and their applications in life sciences , 2009 .

[19]  Katsuyuki Taguchi,et al.  Material separation in x-ray CT with energy resolved photon-counting detectors , 2011, Medical Imaging.

[20]  Aamir Younis Raja,et al.  Using MARS Spectral CT for Identifying Biomedical Nanoparticles , 2013 .

[21]  E. Roessl,et al.  K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors , 2007, Physics in medicine and biology.

[22]  R. Plackett,et al.  Characterization of the Medipix3 pixel readout chip , 2011 .

[23]  Nate D. Tang,et al.  Using algebraic reconstruction in computed tomography , 2012, IVCNZ '12.

[24]  David A Mankoff,et al.  A definition of molecular imaging. , 2007, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[25]  Michael Campbell,et al.  Medipix3: A 64 k pixel detector readout chip working in single photon counting mode with improved spectrometric performance , 2011 .

[26]  P. H. Butler,et al.  The performance of MARS-CT using Medipix3 for spectral imaging of soft-tissue , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[27]  J T Bushberg The AAPM/RSNA physics tutorial for residents. X-ray interactions. , 1998, Radiographics : a review publication of the Radiological Society of North America, Inc.

[28]  T. R. Melzer,et al.  Spectroscopic biomedical imaging with the Medipix2 detector , 2009, Australasian Physics & Engineering Sciences in Medicine.

[29]  Uwe Oelfke,et al.  Imaging properties of small-pixel spectroscopic x-ray detectors based on cadmium telluride sensors , 2012, Physics in medicine and biology.

[30]  Rafidah Zainon,et al.  Spectral Hounsfield units: a new radiological concept , 2012, European Radiology.

[31]  A. J. Bell,et al.  Applying CERN’s detector technology to health: MARS Biomedical 3D spectroscopic x-ray imaging , 2008 .

[32]  Michael Campbell,et al.  The Medipix3RX: a high resolution, zero dead-time pixel detector readout chip allowing spectroscopic imaging , 2013 .

[33]  Sabee Molloi,et al.  Measurement of breast tissue composition with dual energy cone-beam computed tomography: A postmortem study. , 2013, Medical physics.

[34]  J. Butzer,et al.  MARS-CT: Biomedical Spectral X-ray Imaging with Medipix , 2009 .

[35]  Rafidah Zainon,et al.  Toward quantifying the composition of soft tissues by spectral CT with Medipix3. , 2012, Medical physics.

[36]  J. Giersch,et al.  Medical quantum X-ray imaging with 2D detectors , 2005 .

[37]  R. Doesburg,et al.  Spectral CT of carotid atherosclerotic plaque: comparison with histology , 2012, European Radiology.

[38]  M. Rzeszotarski The AAPM/RSNA Physics Tutorial for Residents , 1999 .

[39]  P. H. Butler,et al.  Pixel sensitivity variations in a CdTe-Medipix2 detector using poly-energetic x-rays , 2011 .

[40]  Jan Jakubek,et al.  Energy-sensitive X-ray radiography and charge sharing effect in pixelated detector , 2009 .

[41]  L. Tlustos,et al.  Charge sharing between pixels in the spectral Medipix2 x-ray detector , 2009, 2009 24th International Conference Image and Vision Computing New Zealand.

[42]  J. Schlomka,et al.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography , 2008, Physics in medicine and biology.

[43]  A. A. Fosbinder X-ray interactions , 2002 .

[44]  K. Taguchi,et al.  Vision 20/20: Single photon counting x-ray detectors in medical imaging. , 2013, Medical physics.