Study on Influences and Elimination of Test Temperature on PDC Characteristic Spectroscopy of Oil-Paper Insulation System

Test temperature is an important factor affecting the measurement results of dielectric response of field power transformers. In order to better apply the polarization and depolarization current (PDC) to the condition monitoring of oil-paper insulation system in power transformers, the influences and elimination method of test temperature on PDC characteristic spectroscopy (PDC-CS) were investigated. Firstly, the experimental winding sample was measured by PDC method at different test temperatures, then the PDC-CS was obtained from the measurement results and its changing rules were discussed, which show that the PDC-CS appears a horizontal mobility with the rise of temperature. Based on the rules, the "time temperature shift technique" was introduced to eliminate the influence of test temperature. It is shown that the PDC-CS at different test temperatures can be converted to the same reference temperature coincident with each other.

[1]  R. Rogers IEEE and IEC Codes to Interpret Incipient Faults in Transformers, Using Gas in Oil Analysis , 1978, IEEE Transactions on Electrical Insulation.

[2]  A. Graczkowski,et al.  Frequency response of oil impregnated pressboard and paper samples for estimating moisture in transformer insulation , 2006, IEEE Transactions on Power Delivery.

[3]  Tapan Kumar Saha,et al.  Review of modern diagnostic techniques for assessing insulation condition in aged transformers , 2003 .

[4]  M. Ali,et al.  Degradation of cellulosic insulation in power transformers. Part 2: formation of furan products in insulating oil , 2000 .

[5]  Tapan Kumar Saha,et al.  Effects of temperature on time-domain dielectric diagnostics of transformers , 2004 .

[6]  W. S. Zaengl,et al.  Dielectric Response Methods for Diagnostics of Power Transformers , 2003 .

[7]  P. Purkait,et al.  Deriving an equivalent circuit of transformers insulation for understanding the dielectric response measurements , 2005, IEEE Transactions on Power Delivery.

[8]  A. Setayeshmehr,et al.  Effect of temperature, water content and aging on the dielectric response of oil-impregnated paper , 2008, 2008 IEEE International Conference on Dielectric Liquids.

[9]  M. Ali,et al.  Measuring and understanding the ageing of kraft insulating paper in power transformers , 1996 .

[10]  A. Setayeshmehr,et al.  Dielectric spectroscopic measurements on transformer oil-paper insulation under controlled laboratory conditions , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[11]  P. Purkait,et al.  Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers , 2004, IEEE Transactions on Dielectrics and Electrical Insulation.

[12]  Chen Yufeng Experimental Study of the Aged States Effects on Pressboard PDC Characteristics , 2011 .

[13]  G. Chen,et al.  Recovery voltage measurement on oil-paper insulation with simple geometry and controlled environment , 2004, Proceedings of the 2004 IEEE International Conference on Solid Dielectrics, 2004. ICSD 2004..

[14]  F Meghnefi,et al.  Effect of thermal transient on the polarization and depolarization current measurements , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[15]  Tapan Kumar Saha,et al.  A study of degradation of cellulosic insulation materials in a power transformer. Part 2: tensile strength of cellulose insulation paper , 1995 .

[16]  P. Purkait,et al.  Investigations of Temperature Effects on the Dielectric Response Measurements of Transformer Oil-Paper Insulation System , 2008, IEEE Transactions on Power Delivery.

[17]  V. Der Houhanessian,et al.  Application of relaxation current measurements to on-site diagnosis of power transformers , 1997, IEEE 1997 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.

[18]  C. Burgoyne,et al.  Time-Temperature Superposition to Determine the Stress-Rupture of Aramid Fibres , 2006 .