Optimization of photovoltaic penetration with DSTATCOM in distribution systems

The penetration level of a PV system is often limited due to the violation of voltage variation introduced by the large intermittent power generation. This paper discusses the use of distribution static compensator (DSTATCOM) to compensate reactive power during peak solar irradiation to prevent voltage violation so that the PV penetration level of a distribution feeder can be increased to fully utilize solar energy. The PV power generation is simulated according to the hourly solar irradiation and temperature data provided by the weather bureau. The voltage variation at the point of common coupling (PCC) is also derived by executing the 3-φ load flow analysis to investigate the maximum PV power injection without causing a voltage violation problem. When using the proposed voltage control scheme of the DSTATCOM during high solar irradiation periods, the total power generation and total energy delivered by the PV system over a 1-year period are determined according to the annual duration of solar irradiation. The annual cash flow from sales of PV power, the DSTATCOM installation cost, the O&M cost over the system life cycle, and the capital investment in the PV system are then used to calculate the net present value (NPV) of the PV project. With the proposed voltage control to perform reactive power compensation of the DSTATCOM, the optimal installation capacity of PV systems can be determined by maximizing the net present value of the system so that better cost effectiveness of the PV project and better utilization of solar energy can be obtained.

[1]  P.E. Mercado,et al.  Control Design and Simulation of DSTATCOM with Energy Storage for Power Quality Improvements , 2006, 2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America.

[2]  B. Singh,et al.  Application of DSTATCOM for Mitigation of Voltage Sag for Motor Loads in Isolated Distribution Systems , 2006, 2006 IEEE International Symposium on Industrial Electronics.

[3]  Arindam Ghosh,et al.  Switching Characterization of Cascaded Multilevel-Inverter-Controlled Systems , 2008, IEEE Transactions on Industrial Electronics.

[4]  Arindam Ghosh,et al.  Frequency-domain characterization of sliding mode control of an inverter used in DSTATCOM application , 2006, IEEE Transactions on Circuits and Systems I: Regular Papers.

[5]  G. L. Ockwell Implementation of network reconfiguration for Taiwan Power Company , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[6]  Chung-Sheng Li,et al.  Optimal placement of line switches for distribution automation systems using immune algorithm , 2006, IEEE Transactions on Power Systems.

[7]  Arindam Ghosh,et al.  A flexible DSTATCOM operating in voltage or current control mode , 2002 .

[8]  R. Hara,et al.  Testing the technologies , 2009, IEEE Power and Energy Magazine.

[9]  W.-J. Lee,et al.  Integrated high speed intelligent utility tie unit for disbursed/renewable generation facilities , 2004, Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting..

[10]  Wilsun Xu,et al.  Impacts of AC Generators and DSTATCOM devices on the dynamic performance of distribution systems , 2005, IEEE Transactions on Power Delivery.

[11]  S. Morozumi,et al.  Distribution technology development and demonstration projects in Japan , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.