Identifying Regional Cardiac Abnormalities From Myocardial Strains Using Nontracking-Based Strain Estimation and Spatio-Temporal Tensor Analysis

Myocardial strain is a critical indicator of many cardiac diseases and dysfunctions. The goal of this paper is to extract and use the myocardial strain pattern from tagged magnetic resonance imaging (MRI) to identify and localize regional abnormal cardiac function in human subjects. In order to extract the myocardial strains from the tagged images, we developed a novel nontracking-based strain estimation method for tagged MRI. This method is based on the direct extraction of tag deformation, and therefore avoids some limitations of conventional displacement or tracking-based strain estimators. Based on the extracted spatio-temporal strain patterns, we have also developed a novel tensor-based classification framework that better conserves the spatio-temporal structure of the myocardial strain pattern than conventional vector-based classification algorithms. In addition, the tensor-based projection function keeps more of the information of the original feature space, so that abnormal tensors in the subspace can be back-projected to reveal the regional cardiac abnormality in a more physically meaningful way. We have tested our novel methods on 41 human image sequences, and achieved a classification rate of 87.80%. The regional abnormalities recovered from our algorithm agree well with the patient's pathology and clinical image interpretation, and provide a promising avenue for regional cardiac function analysis.

[1]  Patrick Clarysse,et al.  Mapping Displacement and Deformation of the Heart With Local Sine-Wave Modeling , 2010, IEEE Transactions on Medical Imaging.

[2]  Patrick Clarysse,et al.  Two-dimensional spatial and temporal displacement and deformation field fitting from cardiac magnetic resonance tagging , 2000, Medical Image Anal..

[3]  Dimitris N. Metaxas,et al.  A NOVEL TAG REMOVAL TECHNIQUE FOR TAGGED CARDIAC MRI AND ITS APPLICATIONS , 2007, 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[4]  David Rubin,et al.  Introduction to Continuum Mechanics , 2009 .

[5]  Alejandro F. Frangi,et al.  Multi-sequence Registration of Cine, Tagged and Delay-Enhancement MRI with Shift Correction and Steerable Pyramid-Based Detagging , 2009, FIMH.

[6]  Rik Van de Walle,et al.  Continuous pseudo-inverse image reconstruction in spiral magnetic resonance imaging , 1999, Proceedings 10th International Conference on Image Analysis and Processing.

[7]  Dimitris N. Metaxas,et al.  Extraction and Tracking of MRI Tagging Sheets Using a 3D Gabor Filter Bank , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  Jerry L Prince,et al.  Fast determination of regional myocardial strain fields from tagged cardiac images using harmonic phase MRI. , 2000, Circulation.

[9]  Jerry L. Prince,et al.  Imaging heart motion using harmonic phase MRI , 2000, IEEE Transactions on Medical Imaging.

[10]  Daniel Rueckert,et al.  Analysis of myocardial motion in tagged MR images using nonrigid image registration , 2002, SPIE Medical Imaging.

[11]  Dimitris N. Metaxas,et al.  Segmenting cardiac MRI tagging lines using Gabor filter banks , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[12]  Hans G. Feichtinger Pseudoinverse matrix methods for signal reconstruction from partial data , 1991, Other Conferences.

[13]  Nader Moazami,et al.  Low-Dose Dobutamine Tissue-Tagged Magnetic Resonance Imaging With 3-Dimensional Strain Analysis Allows Assessment of Myocardial Viability in Patients With Ischemic Cardiomyopathy , 2006, Circulation.

[14]  William E. Higgins,et al.  Texture Segmentation using 2-D Gabor Elementary Functions , 1994, IEEE Trans. Pattern Anal. Mach. Intell..

[15]  Dimitris N. Metaxas,et al.  Robust segmentation of 4D cardiac MRI-tagged images via spatio-temporal propagation , 2005, SPIE Medical Imaging.

[16]  Jieping Ye,et al.  Two-Dimensional Linear Discriminant Analysis , 2004, NIPS.

[17]  Daniel Rueckert,et al.  Analysis of 3-D myocardial motion in tagged MR images using nonrigid image registration , 2004, IEEE Transactions on Medical Imaging.

[18]  Leon Axel,et al.  Validation of an optical flow method for tag displacement estimation , 1999, IEEE Transactions on Medical Imaging.

[19]  Leon Axel,et al.  Dense Myocardium Deformation Estimation for 2D Tagged MRI , 2005, FIMH.

[20]  I. Jolliffe Principal Component Analysis , 2002 .

[21]  Nicholas Ayache,et al.  Definition of a four-dimensional continuous planispheric transformation for the tracking and the analysis of left-ventricle motion , 1998, Medical Image Anal..

[22]  Dimitris N. Metaxas,et al.  Non-tracking-based 2D strain estimation in tagged MRI , 2008, 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[23]  Dimitris N. Metaxas,et al.  In-vivo Strain and Stress Estimation of the Left Ventricle from MRI Images , 2002, MICCAI.

[24]  Avinash C. Kak,et al.  PCA versus LDA , 2001, IEEE Trans. Pattern Anal. Mach. Intell..

[25]  Dimitris N. Metaxas,et al.  Boosting and Nonparametric Based Tracking of Tagged MRI Cardiac Boundaries , 2006, MICCAI.

[26]  Nicholas Ayache,et al.  Definition of a 4D continuous polar transformation for the tracking and the analysis of LV motion , 1997, CVRMed.

[27]  Qingshan Liu,et al.  Identifying Regional Cardiac Abnormalities from Myocardial Strains Using Spatio-temporal Tensor Analysis , 2008, MICCAI.

[28]  Jerry L Prince,et al.  Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging , 1999, Magnetic resonance in medicine.

[29]  Ian T. Jolliffe,et al.  Principal Component Analysis , 2002, International Encyclopedia of Statistical Science.

[30]  Daniel Rueckert,et al.  Fast Spatio-temporal Free-Form Registration of Cardiac MR Image Sequences , 2004, FIMH.

[31]  Jerry L Prince,et al.  Visualizing myocardial function using HARP MRI. , 2000, Physics in medicine and biology.

[32]  Jinah Park,et al.  Deformable models with parameter functions for cardiac motion analysis from tagged MRI data , 1996, IEEE Trans. Medical Imaging.

[33]  Patrick Clarysse,et al.  Exploratory analysis of the spatio-temporal deformation of the myocardium during systole from tagged MRI , 2002, IEEE Transactions on Biomedical Engineering.

[34]  M. Pfisterer,et al.  Range of normal values for left and right ventricular ejection fraction at rest and during exercise assessed by radionuclide angiocardiography. , 1985, European heart journal.

[35]  L. Axel,et al.  MR imaging of motion with spatial modulation of magnetization. , 1989, Radiology.