An analytical approach to estimating the first order scatter in heterogeneous medium. II. A practical application.

Recently, the authors proposed an analytical scheme to estimate the first order x-ray scatter by approximating the Klein-Nishina formula so that the first order scatter fluence is expressed as a function of the primary photon fluence on the detector. In this work, the authors apply the scheme to experimentally obtained 6 MV cone beam CT projections in which the primary photon fluence is the unknown of interest. With the assumption that the higher-order scatter fluence is either constant or proportional to the first order scatter fluence, an iterative approach is proposed to estimate both primary and scatter fluences from projections by utilizing their relationship. The iterative approach is evaluated by comparisons with experimentally measured scatter-primary ratios of a Catphan phantom and with Monte Carlo simulations of virtual phantoms. The convergence of the iterations is fast and the accuracy of scatter correction is high. For a sufficiently long cylindrical water phantom with 10 cm of radius, the relative error of estimated primary photon fluence was within +/- 2% and +/- 4% when the phantom was projected with 6 MV and 120 kVp x-ray imaging systems, respectively. In addition, the iterative approach for scatter estimation is applied to 6 MV x-ray projections of a QUASAR and anthropomorphic phantoms (head and pelvis). The scatter correction is demonstrated to significantly improve the accuracy of the reconstructed linear attenuation coefficient and the contrast of the projections and reconstructed volumetric images generated with a linac 6 MV beam.

[1]  P M Evans,et al.  Scattered radiation in portal images: a Monte Carlo simulation and a simple physical model. , 1996, Medical physics.

[2]  Weiguang Yao,et al.  Analytically derived weighting factors for transmission tomography cone beam projections. , 2009, Physics in medicine and biology.

[3]  R Mohan,et al.  Energy and angular distributions of photons from medical linear accelerators. , 1985, Medical physics.

[4]  T Bortfeld,et al.  Correction of scatter in megavoltage cone-beam CT , 2001, Physics in medicine and biology.

[5]  T. Bortfeld,et al.  Direct measurement and analytical modeling of scatter in portal imaging. , 2000, Medical physics.

[6]  J A Seibert,et al.  An edge spread technique for measurement of the scatter-to-primary ratio in mammography. , 2000, Medical physics.

[7]  J H Siewerdsen,et al.  Spektr: a computational tool for x-ray spectral analysis and imaging system optimization. , 2004, Medical physics.

[8]  C. Ma,et al.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.

[9]  S. Richard,et al.  A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT. , 2005, Medical physics.

[10]  Ping Xia,et al.  Low-dose megavoltage cone-beam CT for radiation therapy. , 2005, International journal of radiation oncology, biology, physics.

[11]  Michael Ljungberg,et al.  Comparison of Dual-Window and Convolution Scatter Correction Techniques using the Monte Carlo Method , 1990 .

[12]  C E Floyd,et al.  Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigation. , 1984, Physics in medicine and biology.

[13]  A Fenster,et al.  X-ray scatter in megavoltage transmission radiography: physical characteristics and influence on image quality. , 1994, Medical physics.

[14]  J. Dinten,et al.  A new method for x-ray scatter correction: first assessment on a cone-beam CT experimental setup , 2007, Physics in medicine and biology.

[15]  Weiguang Yao,et al.  An analytical approach to estimating the first order x-ray scatter in heterogeneous medium. , 2009, Medical physics.

[16]  Ruola Ning,et al.  X-ray scatter correction algorithm for cone beam CT imaging. , 2004, Medical physics.

[17]  D. Jaffray,et al.  Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter. , 2001, Medical physics.

[18]  M. Endo,et al.  Effect of scattered radiation on image noise in cone beam CT. , 2001, Medical physics.

[19]  Depth distribution of multiple order X-ray scatter , 2008 .

[20]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.

[21]  Michael Sandborg,et al.  Simulation of scatter in cone beam CT: effects on projection image quality , 2003, SPIE Medical Imaging.

[22]  R. Kruger,et al.  Scatter estimation for a digital radiographic system using convolution filtering. , 1987, Medical physics.

[23]  J. Boone,et al.  An analytical model of the scattered radiation distribution in diagnostic radiology. , 1988, Medical physics.

[24]  Jean Pouliot,et al.  Soft tissue visualization using a highly efficient megavoltage cone beam CT imaging system , 2005, SPIE Medical Imaging.