Abstract. The Full-sun Ultraviolet Rocket SpecTrograph (FURST) is a sounding rocket designed to acquire the first full-disk integrated high resolution vacuum ultraviolet (VUV) spectra of the Sun. The data enable analysis of the Sun comparable to stellar spectra measured by astronomical instruments such as those on board the Hubble Space Telescope. The mission is jointly operated by teams at Montana State University (MSU), developing the instrument, and Marshall Space Flight Center (MSFC), developing the camera and calibration systems, and is scheduled to launch from White Sands Missile Range, New Mexico, in 2022. This mission requires the development of a pre- and post-launch calibration plan for absolute radiometric and wavelength calibration to reliably generate Hubble analogue spectra. Absolute radiometric calibration, though initially planned to be performed at the National Institute for Standards and Technology (NIST) calibration facilities, is now planned to be completed with a portable VUV calibration system provided by MSFC, due to instrument incompatibilities with NIST infrastructure. The portable calibration system is developed to provide absolute wavelength calibration and track changes in calibration over the duration of the mission. The portable calibration system is composed mainly of a VUV collimator equipped with an extreme ultraviolet line source and calibrated photodiodes. The calibration system is developed to accommodate both repeatable wavelength and radiometric testing of the FURST instrument at various test sites before and after launch. Presented here are the requirements, design, and implementation of this portable calibration system with a focus on those features most significant to radiometric measurements.
[1]
Craig J. Sansonetti,et al.
Atlas of the Spectrum of a Platinum/Neon Hollow-Cathode Reference Lamp in the Region 1130–4330 Å
,
2017,
Journal of research of the National Institute of Standards and Technology.
[2]
Mauro Fiorentino,et al.
Spectral characterization of HST calibration lamps: new Pt/Cr-Ne line catalogues and aging test
,
2004,
SPIE Astronomical Telescopes + Instrumentation.
[3]
A. Buck.
The Variable-Path Lyman-Alpha Hygrometer and Its Operating Characteristics.
,
1976
.
[4]
P. S. Athiray,et al.
Simulating charge transport to understand the spectral response of Swept Charge Devices
,
2015,
1509.09046.
[5]
T. Rauch,et al.
New Grids of Pure-hydrogen White Dwarf NLTE Model Atmospheres and the HST/STIS Flux Calibration
,
2020,
The Astronomical Journal.
[6]
George F. Hartig,et al.
Characterization of a Pt-Ne hollow cathode spectral line source.
,
1990,
Applied optics.
[7]
Daniela Calzetti,et al.
Spectrophotometric Standards from the Far-Ultraviolet to the Near-Infrared: STIS and NICMOS Fluxes
,
2001
.